• 제목/요약/키워드: Stress added

검색결과 532건 처리시간 0.021초

DLC 합성시 산소, 수소 및 질소 첨가의 효과 (Effects of oxygen, hydrogen and nitrogen addition in the synthesis of diamond-like carbon films)

  • 황민선;이종무
    • 한국진공학회지
    • /
    • 제8권2호
    • /
    • pp.165-171
    • /
    • 1999
  • Diamond-like carbon(DLC) films were synthesized using the rf-plasma CVD technique with the addition of small amounts of nitrogen and oxygen to a gas mixture of $CH_4$ and $H_2$. The gas flow ratio of $CH_4$ to $H_2$ was 2.4:1, and 3% , 13.6% of nitrogen were added to the gas mixture of $CH_4$ and $H_2$ for the deposition of DLC films. The film stress tended to decrease as the nitrogen concentration increased from 3% to 13.6%, probably due to the decrease of the number of the interlink between carbon atoms. The residual stress tended to slightly decrease when 3% of oxygen was added. Scratch tests were performed to investigate the adhesion between the DLC films and the Ti intelayer after pretreating the TiN surface with direct hydrogen plasma. The adhesion was enhanced by adding nitrogen and oxygen to the $CH_4$ and $H_2$ gas mixture. The adhesion for the 3% nitrogen addition was better than that for the 13.6% nitrogen addition. The Vicker's hardness of the DLC films was measured to be 1100Hv.

  • PDF

해상 풍력 발전 JACKET의 고유 진동수에 관한 연구 (A Study of Natural Frequency of Offshore Wind Turbine JACKET)

  • 이정탁;손충렬;이강수;원종범;김상호;김태용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.434-438
    • /
    • 2006
  • The purpose of this paper is that investigates the Natural Frequency behavior characteristic of Wind Turbine Jacket Type Tower model, and calculated that the stress values of Thrust Load, Wave Load, Wind Load, Current Loda, Gravity Load, etc., environment evaluation analysis during static Operating Wind Turbine Jacket Type Tower model, carried out of Natural Frequency analysis of total load case to stress matrix, Frequency calculated that calculated Add Natural Frequency to stiffness matrix for determinant to stress results. The finite element analysis is performed with commercial F.E.M program (ANSYS) on the basis of the natural frequency and mode shape.

  • PDF

SiN 멤브레인과 WTi 흡수체를 이용한 X-선 노광용 마스크 제작 (Fabrication of a mask for X-ray lithography Using SiN membrane and WTi Absorber)

  • 이문석;김오현
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.115-121
    • /
    • 1995
  • A mask for x-ray lithography is fabricated with SiN membrane and WTi absorber. SiN membrane is deposited by plasma enhanced chemical vapor deposition, and the stress of SiN membrane is controlled to be less than 100 MPa by rapid thermal annealing. WTi absorber is reactively deposited by DC-magnetron type sputter, and the working gases are argon and nitrogen. Added nitrogen is contributed to the stress of WTi absorber. The stress of WTi absorber is controlled to be less than $\pm$ 100 MPa by controlling the deposition pressure. 10$\mu$m WTi pattern is delineated on SiN membrane by dry etching technique.

  • PDF

해상 풍력 발전 JACKET의 고유진동수에 관한 연구 (A Study of Natural Frequency of Offshore Wind Turbine JACKET)

  • 이강수;이정탁;손충렬
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.130-135
    • /
    • 2007
  • The purpose of this paper is that investigates the Natural Frequency behavior characteristic of wind turbine jacket type tower model, and calculated that the stress values of thrust load, wave load, wind load, current loda, gravity load, etc., environment evaluation analysis during static operating wind turbine jacket type tower model, carried out of natural frequency analysis of total load case to stress matrix, frequency calculated that calculated add natural frequency to stiffness matrix for determinant to stress results. The finite element analysis is performed with commercial F.E.M program (ANSYS) on the basis of the natural frequency and mode shape.

Two-Way 스트레치 직물의 열응력분석 연구 (A Study on the Thermal-Stress Properties of Bi-Elastic Woven Fabrics)

  • 전병익
    • 한국산업융합학회 논문집
    • /
    • 제8권3호
    • /
    • pp.149-154
    • /
    • 2005
  • The purpose of this study was to develop the High Functional Stretch Yarns and Woven Fabrics to produce the high value added textile goods and to meet the consumer's needs. For the study 8 yarns and 10 fabrics were made with three develop machine and the thermal-stress properties of the sample were tested and analysed. The result indicated that the sample fabrics kept their stretch performance regardless of conventional process. EDY(elastic DTY) had higher stretch than that of DTY(drawn textured yarn). Especially Macel yarn had higher stretch than that of DTY compared with the same condition of yarn. With time course behavior the elongation of DTY and EDY had stabled tendency without variation. The above results show that wearing sensation and comfort properties of fabrics are changed depending on the end-use. and thus, above results can be used to manufacture of fabrics for specific end-use with high comfort properties.

  • PDF

직무스트레스에 따른 직무만족 요인 조사연구 (Factors Influencing of Job Stress Response to Job Satisfaction)

  • 서장훈;유지철
    • 대한안전경영과학회지
    • /
    • 제5권4호
    • /
    • pp.195-208
    • /
    • 2003
  • All managers should consider both of job performance and job satisfaction as influential key results to be achieved by people at work. One without the other is simply insufficient to meet the high standards of today's workplace. Some workers achieve a sense of personal satisfaction from their jobs while others do not. the others achieve high levels of task performance while others do not. The test of a manager's skill in building value added jobs is to discover what work means to other people, and then to create work environments that help them achieve high levels of both performance and satisfaction. this study set out to investigate the job satisfaction of the employees at work station along with the needs resulting from exploding population of salary citizens. This paper aims to survey and analyze the job satisfaction of the workers and a potent influence factors of Job stress for organization management.

Phospholipase D Is Not Involved in Rho A-Mediated Activation of Stress Fiber Formation

  • Leem, Sun-Hee;Shin, In-Cheol;Kweon, Soo-Mi;Kim, Seung-Il;Kim, Jae-Hong;Ha, Kwon-Su
    • BMB Reports
    • /
    • 제30권5호
    • /
    • pp.337-341
    • /
    • 1997
  • In order to investigate the role of a small GTP-binding protein RhoA in lysophosphatidic acid (LPA)-induced stress fiber formation, C3 ADP-ribosyltransferase was prepared by expressing in E. coli and then applied to Rat-2 fibroblasts. C3 transferase isolated from E. coli was as effective as the toxin from Clostridium botulinum in ADP-ribosylation of RhoA. Incubation of the cells with C3 transferase for 2 days induced ADP-ribosylation of RhoA by a dose-dependent manner, with a sub-maximal induction at $25\;{\mu}g/ml$. As expected, LPA-induced stress fiber formation was completely blocked by pre-incubation with C3 transferase for 2 days. However, exogenously added C3 transferase had no significant effect on the formation of phosphatidylethanol by LPA. These results suggested that phospholipase D was not activated by RhoA in the LPA-induced stress fiber formation.

  • PDF

Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis

  • Hussein, Mostafa Omran
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.333-340
    • /
    • 2013
  • PURPOSE. This study was accomplished to assess the biomechanical state of different retaining methods of bar implant-overdenture. MATERIALS AND METHODS. Two 3D finite element models were designed. The first model included implant overdenture retained by Hader-clip attachment, while the second model included two extracoronal resilient attachment (ERA) studs added distally to Hader splint bar. A non-linear frictional contact type was assumed between overdentures and mucosa to represent sliding and rotational movements among different attachment components. A 200 N was applied at the molar region unilaterally and perpendicular to the occlusal plane. Additionally, the mandible was restrained at their ramus ends. The maximum equivalent stress and strain (von Mises) were recorded and analyzed at the bone-implant interface level. RESULTS. The values of von Mises stress and strain of the first model at bone-implant interface were higher than their counterparts of the second model. Stress concentration and high value of strain were recognized surrounding implant of the unloaded side in both models. CONCLUSION. There were different patterns of stress-strain distribution at bone-implant interface between the studied attachment designs. Hader bar-clip attachment showed better biomechanical behavior than adding ERA studs distal to hader bar.

Rf Magnetron Sputtering 방법으로 제조된 $Ba_{1-x}Sr_xTiO_3$ 박막의 구조적 특성에 대한 연구 (A Study on the Structural Properties of rf Magnetron Sputtered $Ba_{1-x}Sr_xTiO_3$ Thin Film)

  • 김태송;오명환;김종희
    • 한국세라믹학회지
    • /
    • 제30권6호
    • /
    • pp.441-448
    • /
    • 1993
  • The Ba1-xSrxTiO3 thin films deposited on ITO-coated glass substrate at 55$0^{\circ}C$ by rf magnetron sputtering method have individual preferential orientations as a function of composition (X=0, 0.25, 0.5, 0.75, 1) due to the stress relief interactions among the intrinsic compressive stress, thermal tensile stress adn extrinsic compressive stress (compressive stress in case of BaTiO3(Tc=12$0^{\circ}C$) and Ba0.75Sr0.25TiO3(Tc=57$^{\circ}C$)). This behavior also appears on the (BaSr)TiO3 thin films (X=0.5) deposited on ITO-coated glass substrate at deposition temperature between 35$0^{\circ}C$ and 55$0^{\circ}C$. The composition of Ba1-xSrxTiO3 thin films deposited on ITO-coated glass substrate at 55$0^{\circ}C$ is close to stoichiometry (1.009~1.089 in A/B ratio), but the compositional deviation from a stoichiometry is larger as SrTiO3 is added. The morphology of Ba1-xSrxTiO3 thin films is very similar for over all substrate temperatures, and the roughness due to the differences of cluster size is the smallest at X=0.25.

  • PDF

EM시험에서의 Joule Heating 영향 및 초기저항값 (Joule Heating Effects and Initial Resistance in Electromigration Test)

  • 주철원;강형곤;한병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권6호
    • /
    • pp.436-441
    • /
    • 1999
  • Joule heating effect in EM(Electromigration) test were performed on a bend test structure. EM test is done under high current densities(1.0-2.5MA/cm2), which leads to joule heating. Since joule heating is added to the controlled oven(stress) temperature, themetal line temperature is higher than the stress temperature. The increase in the stress temperature due to joule heating is important because EM phenomena and metal line failure are related to the stress temperature. In this paper, metal line was stressed with a current density of 1.0 MA/$cm^2$, 1.5MA/$cm^2$, 2.0MA/$cm^2$, 2.5MA/$cm^2$, for 1200 sec and temperature increase due to joule heating was less than $10^{\circ}C$. Also it took 30 minutes for the metal line to equalized with oven temperature. Recommendations are given for the EM test to determine the initial resistance of EM test structure under stress temperature and current density.

  • PDF