• 제목/요약/키워드: Stress Pattern Analysis

검색결과 551건 처리시간 0.023초

Analysis of Relationship Between Job Stress and Fatigue According to The Type A/B Behavior Pattern of Physical Therapists

  • Wang, Joong San
    • 국제물리치료학회지
    • /
    • 제8권2호
    • /
    • pp.1135-1141
    • /
    • 2017
  • Stress and fatigue are general physical aspects of our daily lives. It has been shown that physical therapists have different levels of job stress and fatigue according to the type A/B behavior patterns. This study collected data from 212 physical therapists between October 28 and November 23, 2016 using an anonymous, self-administered questionnaire. The study results showed the proportion of physical therapists with the Type A behavior patterns(TABP) was 18% greater than that of physical therapists with the Type B behavior patterns(TBBP). In this study, physical therapists with TABP were compared with physical therapists with TBBP. The results indicated that physical therapists with TABP were more inclined to experience higher levels of overall job stress and fatigue from the following stress factors: physical environment, job requirement, and job autonomy. Therefore, the stronger the tendency toward TABP, the stronger the feeling of job stress and fatigue from physical environment, job requirement, and job autonomy. Those with a tendency toward TBBP showed positive correlations between job requirement and the total job stress score; thus, the stronger the tendency toward TBBP, the stronger the feeling of overall job stress and fatigue from job requirement. This study suggests that it is necessary to manage the job stress and fatigue of physical therapists with both TABP and TBBP and to manage the job stress and fatigue of physical therapists with the type A behavioral pattern.

일부 고등학생의 스트레스와 구강건강 관련 연구 (Correlation between stress and oral health in some high school students)

  • 김설희
    • 한국치위생학회지
    • /
    • 제16권3호
    • /
    • pp.409-415
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the correlation between stress and oral health in some high school students. Methods: The subjects were 224 students from three high schools in Daejeon, Daecheon, and Incheon. from November to December, 2015. A self-reported questionnaire was filled out from November to December, 2015. The questionnaire consisted of general characteristics of the subjects, awareness toward stress, stress-coping pattern, oral health-related quality of life and oral health care. Data were analyzed by SPSS 18.0 program. Results: In the analysis of academic stress level by the general characteristics and stress level, higher stress group showed higher experience in stress expectation(high group 16.43, subgroup 9.21), internal stress(high group 13.97, subgroup 6.16), expression type stress(high 10.06, sub-4.95). The higher stress group had emotional stress management in stress-coping pattern and less experience in difficulty of tooth brushing, chewing discomfort, and oral health-related quality of life management(p<0.001). Conclusions: The stress had a negative impact on the oral health related quality of life. The high school students should be able to manage the physical and mental stress. It is necessary to provide the continuous oral health care management against the stress by the dental hygienists.

임플란트의 수와 어태치먼트의 종류에 따른 하악 임플란트 지지 오버덴춰의 삼차원 광탄성 응력분석 (A THREE DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT-SUPPORTED MANDIBULAR OVERDENTURE ACCORDING TO IMPLANT NUMBER AND ATTACHMENT TYPE)

  • 한상훈;태윤섭;진태호;조혜원
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.577-608
    • /
    • 1997
  • The purpose of this study is to evaluate the stress distribution in the bone around dental implants supporting mandibular overdenture according to the number of implant and the type of attachment. Two or four implants were placed in an edentulous mandibular model and three dimensional photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure and also to calculate principal stress components at cervical area of each implant. The attachments tested were rigid and resilient type of Dolder bar, Round bar, Hader bar and Dal-Ro attchment. The results were as follows ; 1. In 2-implant supported overdenture using Round bar, Hader bar, and Dal-Ro attachment, compressive stress pattern was observed on the supporting structure of implant on loaded side, while tensile stress pattern in unloaded side. 2. In 2-implant supported overdenture using Dolder bar, the rigid Dolder bar shared the occlusal loads between 2 implants in a more favorable manner than was exhibited by the resilient type, while the resilient type placed a more stress on the distocervical area of the implant on the loaded side. But compressive stress pattern was observed in both the loaded and unloaded sides in either case. 3. In 2-implant supported overdenture, rigid and resilient type of Dolder bar exhibited more cross arch involvement than the Round bar, Hader bar, or Dal-Ro attachment. 4. In 4-implant supported overdenture using resilient Dolder bar and Hader bar, stress turned out to be distributed evenly among the implants between loaded and unloaded side, but thor was no reduction in the magnitude of the stress in the surrounding structure of implant contratry to 2-implant supported overdenture. 5. The stress pattern at cervical area of implant was different with the number of implant or the type of attachment but the overload, harmful to surrounding structure of implant, was not observed.

  • PDF

막 구조물의 측지선을 이용한 재단도 생성에 관한 연구 (A Study on Cutting Pattern Generation of Membrane Structures by Using Geometric Line)

  • 안상길;손수덕;김승덕
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2005년도 춘계학술발표회 및 정기총회 2권1호(통권2호)
    • /
    • pp.125-132
    • /
    • 2005
  • Membrane structures, a kind of lightweight soft structural system, are used for spatial structures. The material property of the membrane has strong axial stiffness, but little bending stiffness. The design procedure of membrane structures are needed to do shape finding, stress-deformation analysis and cutting pattern generation. In shape finding, membrane structures are unstable structures initially. These soft structures need to be introduced initial stresses because of its initial unstable state, and it happens large deformation phenomenon. And also there are highly varied in their size, curvature and material stiffness. So, the approximation inherent in cutting pattern generation methods is quite different. Therefore, in this study, to find the structural shape after large deformation caused by Initial stress, we need the shape analysis considering geometric nonlinear ten And the geodesic line on surface of initial equilibrium shape and the cutting pattern generation using the geodesic line is introduced.

  • PDF

병원형태별 치과위생사가 임상실습 과정 중 실습생으로부터 경험하게 되는 스트레스 요인에 관한 연구 (A study on stress factors in dental hygienists caused by students in clinical practice by pattern of hospital)

  • 장성연;권순복;양승경
    • 한국치위생학회지
    • /
    • 제13권2호
    • /
    • pp.181-191
    • /
    • 2013
  • Objectives : The research was performed to be used as basic data for dental hygienists' job satisfaction during clinical practice, and planning and operating effective clinical practice by analyzing stress factors in dental hygienists and the extent of stress caused by students in clinical practice. Methods : The research was aimed at dental hygienists working at college dental hospitals, dental clinic of general hospitals, dental hospitals and dental clinics located in Seoul and Gyeonggi province where clinical practices were conducted for dental hygiene students. For analysis, collected data was analyzed by using SPSS 20.0. Results : Results derived from analysis on characteristic difference by pattern of hospital were observed that there was a significant difference in job satisfaction by pattern of hospital. Results from analysis on correlation among stress factors were observed that there was correlation between behavior and attitude, interpersonal relationships, role and activity, ideal and value, and treatment fields. Results derived from analysis on the effect of stress factors on the job satisfaction were observed that role and activity (p=.002<.01), ideal and value (p=.019<.05), and treatment fields (p=.032<.05) affected the job satisfaction, while behavior and attitude (p=.386>.05), and interpersonal relationships ((p=.421>.05) did not affect the job satisfaction. A stress factor, role and activity (${\beta}$=.350) affected the job satisfaction the most, followed by ideal and value (${\beta}$=.242), and treatment fields (${\beta}$=-.185). For the explanation ability, the stress factors accounted for 20.5% of the job satisfaction. Conclusions : In conclusion, most of the dental hygienists are satisfied with students' clinical practice by pattern of hospital. Positive correlation was shown between stress factors. Behavior and attitude and ideal and value are high in stress in college dental hospitals, role and activity and treatment fields are high in stress in dental hospital, and interpersonal relationships are high in stress in dental clinics.

SPATE에 의한 등방성체의 응력확대계수 측정 (Measurement of Stress Intensity Factor of Isotropic Material Using SPATE)

  • 황재석;서재국;이효재;남정환;;최영철
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.393-404
    • /
    • 1997
  • SPATE(Stress Pattern Analysis by Thermal Emission) can be effectively used to analyze the stress distributions of isotropic structure under the repeated load by non-contact. In this research, the measuring method and the measuring concept of stress intensity factor of isotropic material by SPATE are suggested. The validity of the method and the concept was certified through SPATE experiment.

SPATE에 의한 직교이방성체의 응력확대계수 측정 (Measurement of Stress Intensity Factor of Orthotropic Material Using SPATE)

  • 황재석;서재국;이효재;남정환
    • 대한기계학회논문집A
    • /
    • 제20권10호
    • /
    • pp.3224-3233
    • /
    • 1996
  • SPATE(Stress Pattern Analysis by Thermal Emission) can be effectively used to analyze the stress distribution of the orthotropic structure under the repeated load by non-contact. In this research, the measuring conception and method of stress intensity factor of orthotropic material using SPATE are suggested. The relationships between the maximum values of SPATE signal and $1/\sqrt{X'}$ (or $1/\sqrt{y'}$) are theoretically established in the vicinity of crack tip of the orthotropic material. It is certified through SPATE experiment that their linear quality is very excellent.

한반도지역의 현지응력장 분포 패턴 및 지질시대별 전이 추이 (Regional Distribution Pattern and Geo-historical Transition of In-situ Stress Fields in the Korean Peninsula)

  • 신중호;박찬;이병주
    • 터널과지하공간
    • /
    • 제23권6호
    • /
    • pp.457-469
    • /
    • 2013
  • 국내 100여개 지역에서 측정된 460개 현지응력자료를 종합 분석하여 국내의 광역적 현지응력 분포 패턴을 분석하고, 심도-응력 및 심도-측압계수 관계식을 제시하였다. 이와 함께 한반도의 지질시대별 고응력장 변화와 최근의 지진 메카니즘에 의한 응력장 추정 결과를 통합하여, 한반도지역의 응력장 분포 패턴인 한국응력지도(Korea Stress Map)를 작성하였다. 세계의 심도-응력 관계식들과 비교를 통해, 본 연구에서 도출된 관계식의 적합성과 수 km 심도에의 유추 적용성을 확인하였다. 그리고 세계응력지도(World Stress Map)과 함께 동북아시아지역의 응력장 패턴을 분석하였다.

임플랜트와 지대주 간 내측연결 시스템에서 Friction Fit와 Slip Fit에 따른 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis According to Friction Fit or Slip Fit of Internal Connection System between Implant and Abutment)

  • 장두익;정승미;정재헌
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.113-132
    • /
    • 2005
  • The purpose of this study was to assess the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to a friction-fit joint (Astra; Model 1) or slip- fit joint (Frialit-2; Model 2) in the internal connection system under vertical and inclined loading using finite element analysis. In conclusion, in the internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to the abutment connection form had difference among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the abutment post. The magnitude of the stress distributed in the supporting bone, the implant fixture, the abutment and the abutment screw was higher in the friction-fit joint than in the slip-fit joint. But it is considered that the further study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

임플랜트-지대주의 연결방법에 따른 임플랜트 보철의 유한요소 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO CONNECTION TYPES OF IMPLANT-ABUTMENT)

  • 허진경;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.544-561
    • /
    • 2005
  • Purpose : This study was to assess the loading distributing characteristics of implant systems with internal connection or external connection under vertical and inclined loading using finite element analysis. Materials and methods : Two finite element models were designed according to type of internal connection or external connection The crown for mandibular first molar was made using cemented abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the centric cusp tip in a 15$^{\circ}$ inward inclined direction (loading condition B), or 200N at the centric cusp tip in a 30$^{\circ}$ outward inclined direction (loading condition C) respectively. Von Mises stresses were recorded and compared in the supporting bone, fixture, abutment and abutment screw. Results : 1. In comparison with the whole stress or the model 1 and model 2, the stress pattern was shown through th contact of the abutment and the implant fixture in the model 1, while the stress pattern was shown through the abutment screw mainly in the model 2. 2. Without regard to the loading condition, greater stress was taken at the cortical bone, and lower stress was taken at the cancellous bone. The stress taken at the cortical bone was greater at the model 1 than at the model 2, but the stress taken at the cortical bone was much less than the stress taken at the abutment, the implant fixture, and the abutment screw in case of both model 1 and model 2. 3. Without regard to the loading condition, the stress pattern of the abutment was greater at the model 1 than at the model 2. 4. In comparison with the stress distribution of model 1 and model 2, the maximum stress was taken at the abutment in the model 1. while the maximum stress was taken at the abutment screw in the model 2. 5. The magnitude of the maximum stress taken at the supporting bone, the implant fixture, the abutment, and the abutment screw was greater in the order of loading condition A, B and C. Conclusion : The stress distribution pattern of the internal connection system was mostly distributed widely to the lower part along the inner surface of the implant fixture contacting the abutment core through its contact portion because of the intimate contact of the abutment and the implant fixture and so the less stress was taken at the abutment screw, while the abutment screw can be the weakest portion clinically because the greater stress was taken at the abutment screw in case of the external connection system, and therefore the further clinical study about this problem is needed.