• Title/Summary/Keyword: Strain Gauge System

Search Result 201, Processing Time 0.025 seconds

Microcomputer Based Vacuum Drying System and its Application to the Vacuum Drying of Green Red Pepper (마이크로컴퓨터 감압건조(減壓乾燥)시스템의 제작운영(製作運營)과 풋고추의 감압건조특성(減壓乾燥特性))

  • Chun, Jae-Kun;Kang, Jun-Soo
    • Applied Biological Chemistry
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 1987
  • In Girder to measure the pressure and weight decrease of drying sample during the vacuum drying process of food, sensing devices were designed and constructed with strain gauge. Microcomputer based vacuum drying system was made up of these devices interfaced to apple II microcomputer. The electrical output signal from vacuum sensor which constituted with Bourdon tube whereon strain gauge attached were digitalized and input to microcomputer through the MC 6821 interface I.C. chip. The relationship between read-out digital value (D) from microcomputer and readings of vacuum gauge (P, mmHg) was P=-146.136+3.620D'(r=0.9994) The pressure control of vacuum dryer was successfully conducted in the range of $400{\sim}600\;mmHg$ accuracy. The digitalized load cell output (D) could be correlated with the real weight (W, g) as W=-14,000+0.585D (r=0.9998) Drying curves of green red pepper under $64^{\circ}C$, $400{\sim}600\;mmHg$ was similar to those of red pepper and differently affected by the degree of vacuum pressure but was varied according to their shape (cut or whole). Moisture movement of green red pepper during the vacuum drying process was fitted to Page model. The empirical equations obtained were $M-M_e/M_o-M_e={\exp}\;(-0.0673{\theta}^{1.177})$ and $M-M_e/M_o-M_e={\exp}\;(-0.0655\;{\theta}^{1.477})$ for whole and cut green red pepper, respectively.

  • PDF

Characteristics and Applications of a Strain Modal Testing Method (변형률 모드시험방법의 특성 및 응용)

  • 차주환;하태희;이건명
    • Journal of KSNVE
    • /
    • v.8 no.3
    • /
    • pp.420-427
    • /
    • 1998
  • A strain modal testing method has been applied to a cantilever beam to investigate the characteristics of the method. By applying the method to an analytical and an experimental system, it was shown that accurate modal parameters can be estimated from strain frequency response functions using a current modal parameter extraction algorithm. The modal parameters estimated by the method are more accurate than those by the conventional method which uses accelerometers when the tested system is of light weight. The method can be used to predict strain responses and excitation forces for given excitation forces and responses, respectively. Cracks on a structure can be detected by measuring strian FRFs and comparing them with the original ones.

  • PDF

Study on Torque precision measuring System using Curve Fitting Algorithm (커브피팅 알고리즘이 적용된 토크 정밀 측정 시스템 개발에 관한 연구)

  • Lee, Ki Won;Ha, Jae Seung;Kang, Seung Soo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.4
    • /
    • pp.1-11
    • /
    • 2012
  • This paper is the study on the development of a torque precision measuring system using the curve fitting algorithm. This system can be divided into the hardware part and the software part. The hardware part consists of the main base board, the DAQ(Data Aquisition) board and Calibration parts. The software part consists of the software filter module and the curve fitting algorithm module. We have tested the torque transducer including the strain gauge for 200 Nm range and have analyzed the data acquired with the curve fitting algorithm by using this system. The DAQ board converts the electric signal induced by the transducer to the digital value precisely by using the shunt calibration procedure. The main board including the curve fitting algorithm calculates the exact digital torque value by using the digital value from the DAQ board. In this study, we confirmed that the result of the appropriate high-order power-series polynomial function is more accurate than the result of the low-order power-series polynomial through the system.

An Estimation of Behavior for Wedge type Removable Soil Nailing System by Field Trial Construction (현장시험시공을 통한 쐐기형 제거식 쏘일네일링 공법의 거동 평가)

  • Han, Yeon-Jin;Park, Si-Sam;Kwon, Hyuk-Jun;Kim, Hong-Taek;Park, Ju-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1360-1364
    • /
    • 2009
  • Necessity of removable soil nailing has been arisen in the soil nailing system because of problem such as civil petition for geotechnical environment and invasion of the ground boundary line and payments for use besides geotechnical engineering. Removable soil nailing system is improved soil nailing system that fixed socket arranged in boring hole for increasement of skin friction. In this study, field pull-out tests are carried out more 4 times considering installed distance of fixed socket and analyze skin friction behavior characteristics in fixed socket through analysis of measurements of strain gauge attached to fixed socket. Also, to evaluate application for wedge type removable soil nailing system analyzing displacement aspects through field pull-out tests by trial construction.

  • PDF

A Study of the Shaft Power Measuring System Using Cameras (카메라를 이용한 축계 비틀림 계측 장치 개발)

  • Jeong, Jeong-Soon;Kim, Young-Bok;Choi, Myung-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.72-77
    • /
    • 2010
  • This paper presents a method for measuring the shaft power of a marine main engine. Usually, in traditional systems for measuring shaft power, a strain gauge is used even though it has several disadvantages. First, it is difficult to set up the strain gauge on the shaft and acquire the correct signal for analysis. Second, it is very expensive and complicated. For these reasons, we investigated alternative approaches for measuring shaft power and proposed a new method that uses a vision-based measurement system. For this study, templates for image processing and CCD cameras were installed at the both ends of the shaft. Then, in order for the cameras to capture the images synchronously, we used a trigger mark and a optical sensor. The position of each template between the first and the second camera images were compared to calculate the torsion angle. The proposed measurement system can be installed more easily than traditional measurement systems and is suitable for any shaft because it does not contact the shaft. With this approach, it is possible to measure the shaft power while a ship is operating.

The Research of the Strain Measuement Method on the Stress Concentration Area using 3D-ESPI System (3D-ESPI System을 이용한 응력집중부의 변형률 측정기법 연구)

  • 김경수;심천식;전종욱;김덕호
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.150-153
    • /
    • 2001
  • In this paper, the tensile test of three kinds of the specimens was performed. Type I specimen is without notch and type II, III specimens have a radius of semi-circular edge crack of 2.5mm, 4.0mm. The tensile load(20kN and 30kN) was applied to the specimen by Universal Testing Machine. 3D-ESPI system and strain gauge measured simultaneously the strain in the center of the specimen and near the edge crack. The test results were compared with each other. Moreover, the stress concentration factor based on geometric information was calculated to confirm the accuracy of the strain measured by 3D-ESPI system. The calculated strain was compared with the measured one by 3D-ESPI system. As a result, it was confirmed that 3D-ESPI system measured the right strain near the semi-circular edge crack of the specimens.

  • PDF

Measurement of Near Field Sound Intensity and Loss Factor Using Plate Intensity Measurement (평판 인텐시티 측정을 통한 근접장 음향 인텐시티와 손실 계수 측정법)

  • 김용조;김양한
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.589-596
    • /
    • 1997
  • A energy equation for a thin plate and surrounding fluid is derived. The equation essentially determines the relation between internal loss of thin plate, energy of acoustic radiation, and structure intensity. We attempted to use this relation to measure internal loss of thin plate. The significance of this approach is that internal loss at any point of a thin plate can be measured. The quality of this measure is dicated by the accuracy of associated measurement systems such as structure and acoustic intensity measurements. A strain gauge bridge system has been developed to measure structure intensity of thin plate. Its performance is tested by experiments.

  • PDF

Development and Application of A Smart Anchor with Optical FBG Sensors (FBG 센서를 내장한 스마트 앵커의 개발과 적용)

  • Kim, Young-Sang;Suh, Dong-Nam;Kim, Jae-Min;Lee, Seung-Rae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.393-398
    • /
    • 2008
  • With the substantial increase of the size of structure, management and monitoring of excavation for the foundation construction becomes more difficult. Therefore, massive collapses which are related to retaining wall recently increase. However, since the study on measuring and monitoring the pre-stressing force of anchor is insufficient, behavior of anchor may not be predicted and monitored appropriately by the existing strain gauge type monitoring system. FBG Sensor, which is smaller than strain gauge and has better durability and does not have a noise from electromagnetic waves, was adapted to develope a smart anchor. A series of pullout tests were performed to verify the feasibility of smart anchor and find out the load transfer mechanism around the steel wire fixed to rock with grout.

  • PDF

Output Characteristics and Sensitivity Analysis of Capacitive Type Torque Sensor (정전용량방식 토크센서의 출력특성과 감도해석)

  • Lee, Shin-Pyo;Kim, Jong-Bo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2590-2597
    • /
    • 2002
  • A new torque measuring apparatus adopting the basic principle of a capacitive type sensor is proposed in this article. Two plate electrodes are working as a capacitive sensor, whose capacitance varies as torque is applied. One end of each plate is connected to the torque carrying shaft. Output characteristics of the torque sensor were theoretically analyzed and its validity was investigated through experiment. Calculations and calibration experiments show that the output is nonlinear, that is, the sensitivity is very high at low torque but decreases as torque increases. The sensitivity of the proposed system is about 100 times roughly higher than that of a conventional 4-strain gauge type torque sensor.

Development of Thin-Film Type Strain Gauges for High-Temperature Applications (고온용 박막형 스트레인 게이지 개발)

  • Choi, Sung-Kyu;Chung, Gwiy-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1596-1598
    • /
    • 2002
  • This paper presents the characteristics of Ta-N thin-film strain gauges as high-temperature strain gauges, which were deposited on Si substrate by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-($4{\sim}16%$)$N_2$). These films were annealed for 1 hour in $2{\times}10^{-6}$ Torr vacuum furnace range $500{\sim}1000^{\circ}C$. The optimized conditions of Ta-N thin-film strain gauges were annealing condition($900^{\circ}C$, 1 hr.) in 8% $N_2$ gas flow ratio deposition atmosphere. Under optimum conditions, the Ta-N thin-films for strain gauges is obtained a high resistivity, ${\rho}$=768.93 ${\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR = -84 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal gauge factor, GF = 4.12.

  • PDF