• Title/Summary/Keyword: Storage battery

Search Result 887, Processing Time 0.026 seconds

A cohort study on blood zinc protoporphyrin concentration of workers in storage battery factory (축전지 공장 근로자들의 혈중 Zinc Protoporphyrin에 대한 코호트 연구)

  • Jeon, Man-Joong;Lee, Joong-Jeong;SaKong, Joon;Kim, Chang-Yoon;Kim, Jung-Man;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.112-126
    • /
    • 1998
  • To investigate the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, the blood zinc protoporphyrin (ZPP) concentrations of 131 workers (100 exposed subjects and 31 controls) of a newly established battery factory were analyzed. They were measured in every 3 months up to 18 months. Ai. lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean blood ZPP concentration of the controls was $16.45{\pm}4.83{\mu}g/d\ell$ at the preemployment examination and slightly increased to $17.77{\pm}5.59{\mu}g/d\ell$ after 6 months. Mean blood ZPP concentration of the exposed subjects who were employed before the factory was in operation (Group A) was $17.36{\pm}5.20{\mu}g/d\ell$ on employment and it was increased to $23.00{\pm}13.06{\mu}g/d\ell$ after 3 months. The blood ZPP concentration was increased to $27.25{\pm}6.40{\mu}g/d\ell$ on 6 months (p<0.01) after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $25.48{\mu}g/d\ell$ and $26.61{\mu}g/d\ell$ in the subsequent 4 results. Mean blood ZPP concentration of the exposed subjects who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $14.34{\pm}6.10{\mu}g/d\ell$ on employment and it was increased to $28.97{\pm}7.14{\mu}g/d\ell$ (p<0.01) in 3 months later(1 month after the intervention). The values of subsequent 4 tests were maintained between $26.96{\mu}g/d\ell$and $27.96{\mu}g/d\ell$. Mean blood ZPP concentration of the exposed subjects who were employed after intervention program had been started (Group C) was$21.34{\pm}5.25{\mu}g/d\ell$ on employment and it was gradually increased to $23.37{\pm}3.86{\mu}g/d\ell$ (p<0.01) after 3 months, $23.93{\pm}3.64{\mu}g/d\ell$ after 6 months, $25.50{\pm}3.01{\mu}g/d\ell$ after 9 months, and $25.50{\pm}3.10{\mu}g/d\ell$ after 12 months. Workplaces were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3$ and$0.208mg/m^3$ in follow-up test. The Pb-A of part II which was resulted in lowe. value than part I was decreased from $0.232mg/m^3$ to $0.148mg/m^3$, and $0.120mg/m^3$ after the intervention. The Pb-A of part III was tested after the intervention and resulted in $0.124mg/m^3$ in January 1988 and $0.181mg/m^3$ in August 1988. The Pb-A of part IV was also tested after the intervention and resulted in $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-A and blood ZPP concentration. The blood ZPP concentration of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. The blood ZPP concentration of the workers in the part of the lowest Pb-A increased more rapidly. The blood ZPP concentration of the group C workers was the highest in part III. These findings suggest that the intervention in personal hygiene is more effective than environmental intervention, and it should be carried out from the first day of employment and to both the exposed subjects, blue color workers and the controls, white color workers.

  • PDF

The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers (연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화)

  • Kim, Yong-Bae;Ahn, Hyun-Cheol;HwangBo, Young;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

International Conference on Electroceramics 2005 (2005년도 국제 전자세라믹 학술회의)

  • 한국세라믹학회
    • Proceedings of the Korean Ceranic Society Conference
    • /
    • 2005.06a
    • /
    • pp.1-112
    • /
    • 2005
  • This report is results of a research on recent R&D trends in electroceramics, mainly focusing on the papers submitted to the organizing committee of the International Conference on Electroceramics 2005 (ICE-2005) which was held at Seoul on 12-15 June 2005. About 380 electroceramics researchers attended at the ICE-2005 from 17 countries including Korea, presenting and discussing their recent results. Therefore, we can easily understand the recent research trends in the field of electroceramics by analyses of the subject and contents of the submitted papers. In addition to the analyses of the papers submitted to the ICE-2005, we also collected some informations about domestic and international research trends to help readers understand this report easily. We analysed the R&D trends on the basis of four main categories, that is, informatics electroceramics, energy and environment ceramics, processing and characterization of electroceramics, and emerging fields of electroceramics. Each main category has several sub-categories again. The informatics ceramics category includes integrated dielectrics and ferroelectrics, oxide and nitride semiconductors, photonic and optoelectronic devices, multilayer electronic ceramics and devices, microwave dielectrics and high frequency devices, and piezoelectric and MEMS applications. The energy and environment ceramics category has four sub-categories, that is, rechargable battery, hydrogen storage, fuel cells, and advanced energy conversion concepts. In the processing and characterization category, there exist domain, strain, and epitaxial dynamics and engineering sub-category, innovative processing and synthesis sub-category, nanostructured materials and nanotechnology sub- category, single crystal growth and characterization sub-category, theory and modeling sub-category. Nanocrystalline electroceramics, electroceramics for smart sensors, and bioceramics sub-categories are included to the emerging fields category. We hope that this report give an opportunity to understand the international research trend, not only to Korean ceramics researchers but also to science and technology policy researchers.

  • PDF

Macroporous Thick Tin Foil Negative Electrode via Chemical Etching for Lithium-ion Batteries (화학적 식각을 통해 제조한 리튬이온 이차전지용 고용량 다공성 주석후막 음극)

  • Kim, Hae Been;Lee, Pyung Woo;Lee, Dong Geun;Oh, Ji Seon;Ryu, Ji Heon
    • Journal of the Korean Electrochemical Society
    • /
    • v.22 no.1
    • /
    • pp.36-42
    • /
    • 2019
  • A macroporous Sn thick film as a high capacity negative electrode for a lithium ion secondary battery was prepared by using a chemical etching method using nitric acid for a Sn film having a thickness of $52{\mu}m$. The porous Sn thick film greatly reduced the over-voltage for the alloying reaction with lithium by the increased reaction area. At the same time. The porous structure of active Sn film plays a part in the buffer and reduces the damage by the volume change during cycles. Since the porous Sn thick film electrode does not require the use of the binder and the conductive carbon black, it has substantially larger energy density. As the concentration of nitric acid in etching solution increased, the degree of the etching increased. The etching of the Sn film effectively proceeded with nitric acid of 3 M concentration or more. The porous Sn film could not be recovered because the most of Sn was eluted within 60 seconds by the rapid etching rate in the 5 M nitric acid. In the case of etching with 4 M nitric acid for 60 seconds, the appropriate porous Sn film was formed with 48.9% of weight loss and 40.3% of thickness change during chemical acid etching process. As the degree of etching of Sn film increased, the electrochemical activity and the reversible capacity for the lithium storage of the Sn film electrode were increased. The highest reversible specific capacity of 650 mAh/g was achieved at the etching condition with 4 M nitric acid. The porous Sn film electrode showed better cycle performance than the conventional electrode using a Sn powder.

The relationships between lead exposure indicies and urinary δ-ALA by HPLC and colorimetric method in lead exposure workers (연노출근로자에 있어서 흡광광도법과 HPLC법에 의한 요중 δ-ALA 배설량과 연노출지표들 간의 관련성)

  • Ahn, Kyu-Dong;Lee, Sung-Soo;Hwangbo, Young;Lee, Gab-Soo;Yeon, You-Yong;Kim, Yong-Bae;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.77-87
    • /
    • 1996
  • In order to compare the difference of the measurement of delta aminolevulinic acid(${\delta}$-ALA) in urine between HPLC method(HALA) and colorimetric method(CALA), and also to provide useful information for the new diagnostic criteria of ${\delta}$-ALA in urine in lead poisoning, if at all possible in the future, authors studied 234 male lead workers who were selected from 7 storage battery factories, 3 secondary smelting industries, and 2 litharge making industries. Study subjects were selected on the basis of blood Zinc protoporphyrin(ZPP) level from low to high concentration to cover wide range of lead exposure. Study variables for this study were ${\delta}$-ALA measured by two different methods, blood lead(PbB), and blood ZPP. The results were as follows: 1. There was very high correlation between ${\delta}$-ALA measured by two method(r = 0.989 : HALA = -0.8194 + 0.8110 ${\times}$ CALA), but the value of CALA was measured about 2mg/L greater than HALA. 2. While the correlations of ${\delta}$-ALA by two method with blood lead and blood ZPP were 0.46 and 0.37 respectively, they were increased to 0.63 and 0.57 if ${\delta}$-ALA values were log-transformed. 3. Simple linear regression of ${\delta}$-ALA measured by two method on ZPP were as follows: CALA = 2.0421 + 0.0341 ${\times}$ ZPP ($R^2=0.1385$ p = 0.0001) HALA = 0.8006 + 0.0280 ${\times}$ ZPP ($R^2=0.1389$ p = 0.0001) 4. Simple linear regression of ${\delta}$-ALA measured by two method on PbB were as follows: CALA = - 0.4134 + 0.1545 ${\times}$ PbB ($R^2=0.2085$ p = 0.0001) HALA = -1.2893 + 0.1287 PbB ($R^2=0.2154$ p = 0.0001), 5. Simple linear regression of log-transformed ${\delta}$-ALA by two method on ZPP and PbB were as follows: logHALA = 0.3078 + 0.0060 ZPP ($R^2=0.3329$ p = 0.0001) logCALA = 1.0189 + 0.0044 ZPP ($R^2=0.3290$ p = 0.0001) logHALA = -0.0221 + 0.0246 PbB ($R^2=0.4046$ p = 0.0001) logCALA = 0.7662 + 0.0184 PbB ($R^2=0.4108$ p = 0.0001) 6. The cumulative percent of colorimetric method to detect lead workers whose value of PbS and ZPP were over screening level such as $40{\mu}/dl$ and $100{\mu}/dl$ respectively was higher than HPLC method if cut-off level of ${\delta}$-ALA for screening of lead poisoning was 5 mg/L. But if cut-off level of ${\delta}$-ALA measured by HPLC was reduced to 3 mg/L which is compatible to 5 mg/L of ${\delta}$-ALA measured by colorimetric method, there were good agreement between two methods and showed dose-response relationship with other lead exposure indices such as PbB and ZPP.

  • PDF

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.

  • PDF