• Title/Summary/Keyword: Steel-tube

Search Result 1,107, Processing Time 0.024 seconds

Evaporative Heat Transfer Characteristics of Carbon Dioxide in a Horizontal Tube (수평관내 이산화탄소의 증발 열전달 특성)

  • Son Chang-Hyo;Lee Dong-Gun;Kim Young-Lyoul;Oh Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1134-1139
    • /
    • 2004
  • The evaporative heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 7.75 mm. The experiments were conducted at mass flux of 200 to 500 kg/m$^2$s, saturation temperature of -5 to 5$^{\circ}C$, and heat flux of 10 to 40kW/m$^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much, and the effect of mass flux on evaporative heat transfer of $CO_2$ is much smaller than that of refrigerant R-22 and R-134a. In comparison with test results and existing correlations, correlations failed to predict the evaporative heat transfer coefficient of $CO_2$, therefore, it is necessary to develope reliable and accurate predictions determining the evaporative heat transfer coefficient of $CO_2$ in a horizontal tube.

Evaluation of the Microstructures and Mechanical Properties on Friction Welded STK400 Tube (마찰접합 된 STK400 Tube의 미세조직과 기계적 특성 평가)

  • Kim, Gyeong-Woo;Song, Kuk-Hyun
    • Korean Journal of Materials Research
    • /
    • v.29 no.1
    • /
    • pp.30-36
    • /
    • 2019
  • We evaluate the properties of friction welded STK400 steel tube in terms of the relationship between microstructures and mechanical properties. Friction welding is conducted at a rotation speed of 1,600 rpm and upset time of 3-7 sec for different thicknesses of STK 400 tubes. To analyse the grain boundary characteristic distributions(GBCDs) in the welded zone, electron backscattering diffraction(EBSD) method is introduced. The results show that a decrease in welding time (3 sec.) creates a notable increase grain refinement so that the average grain size decreases from $15.1{\mu}m$ in the base material to $4.5{\mu}m$ in the welded zone. These refined grains achieve significantly enhanced microhardness and a slightly higher yield and higher tensile strengths than those of the base material. In particular, all the tensile tested specimens experience a fracture aspect at the base material zone but not at the welded zone, which means a soundly welded state for all conditions.

Strength of connection fixed by TOBs considering out-of-plane tube wall deformation-Part 1: Tests and numerical studies

  • Wulan, Tuoya;Wang, Peijun;Xia, Chengxin;Liu, Xinyu;Liu, Mei;Liu, Fangzhou;Zhao, Ou;Zhang, Lulu
    • Steel and Composite Structures
    • /
    • v.42 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • This paper presents a study on the behavior of a bolted T-stub to square tube connection using Thread-fixed One-side Bolts (TOBs) through tests and numerical simulations. It outlines a research work of four connections with focus on the failure modes and strengths of the connection under tensile load. It was observed that the thread anchor failure caused by shear failure of hole threads controlled the final failure of the connection in the tests. Meanwhile, the out-of-plane deformation of tube wall resulted in the contact separation between hole threads and bolt threads, which in turn reduced the shear strength of hole threads. Finite element models (FEMs) allowing for the configuration details of the TOBs fixed connection are then developed and compared with the test results. Subsequently, the failure mechanism of hole threads and stress distribution of each component are analyzed based on FEM results. It was concluded that the ultimate strength of connection was not only concerned with the shear strength of hole threads, but also was influenced by the plastic out-of-plane deformation of tube wall. These studies lay a foundation for the establishment of suitable design methods of this type of connection.

Analytical Approach for the Noise Properties and Geometric Scheme of Industrial CR Images according to Radiation Intensity (산업용 CR영상의 방사선 강도에 따른 잡음특성과 기하학적 구도형성의 해석적 접근)

  • Hwang, Jung-Won;Hwang, Jae-Ho;Park, Sang-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.1
    • /
    • pp.56-62
    • /
    • 2009
  • In this paper we investigate an analytical approach for noise properties and geometric structure in Computed Radiography(CR) images of industrial steel-tubes. Over thirty diverse radiographic images are sampled from industrial radiography measurements according to radiation intensity. Each image consists of three regions; background, thickness and inner-tube. Among these the region of inner-tube is selected for the object of analysis. Geometric structure which includes the noise generation is analyzed by the statistical and functional methodology. The analysis is carried on spacially and line by line. It verifies the geometrical transfigure from the circle configuration of steel-tube and noise variation. The estimation of fitting function and its error are the geometric factors. The statistics such as standard deviation, mean and signal-to-noise ratio are noise parameters for discrimination. These factors are considered under the intensity variation which is the penetrative strength of radiation. The analysing results show that the original geometry of circle is preserved in the form of elliptic or short/long diameter circle, and the noise deviation has increased inverse proportional to the radiation intensity.

A Theoretical and Numerical Study on the Effects of Prereinforcement of Tunnel Face (터널막장 선행보강 효과에 관한 이론적.수치해석적 연구)

  • 김광진;문현구
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.328-338
    • /
    • 2001
  • Horizontal tunnel face reinforcement using Fiber Glass Tube(FGT) or steel pipe and pipe roofing techniques are frequently used when the stability of newly excavated tunnel is not guaranteed. However, the mechanical behavior of tunnels using these techniques has not been fully understood so far. Therefore, engineering rule of thumb is commonly applied during designing procedure, and it is difficult to adopt these techniques rationally. In this study, the application of a simplified numerical analysis method based on composite mechanics is verified. The mean field theory and the strain energy theory are used to obtain the equivalence elastic moduli of reinforced soil and rock. Furthermore, a parametric study on the deformational behavior of tunnel face is performed for various patterns of prereinforcement.

  • PDF

Estimation of Damage Using Accelerometer of 3 Axial in Reinforcement Concrete (3축 가속도계를 이용한 철근 콘크리트 보에서의 손상평가)

  • Kim, Ie-Sung;Park, Kang-Geun;Kim, Tae-Gon;Kim, Dong-Hyeok;Kim, Wha-Jung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.75-83
    • /
    • 2008
  • The R.C Building will be superannuated as time passes by heavy load and serviceability. Methods of damage detection are used a visual angle of human or non-destructive test in the R.C Building. In case of the latter, Problems of damage detection are occurred to directions of steel bar. Elastic waves are difficult to assaying test using 1 axial type of accelerometer in reinforced concrete. In this study, fundamental studies for estimations using 3 axial type of accelerometer are discussed oscillator of elastic waves when embedded glass tube pipe or steel bar in flexible concrete specimens.

  • PDF

A Study on the Structural Properties of RC Beams with Web Openings using Square Steel Tube (각형강관을 이용한 RC 유공보의 구조 특성 연구)

  • Lee, Seung-Jo;Park, Jung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.85-86
    • /
    • 2010
  • This study is aimed to investigate on the structural properties (like as strength, failure mode, ductility) of beams with web openings reinforced with steel tube of square. The main parameters are follows; 1) with and without web opening 2) the number of opening, 3) location of openings. In the quasi-static tests, structural properties of PFBS1A and PFBS2A were most superior. When the locations of opening are respectively maximal moment zone (M), shear (S), co-existence area of moment and shear (M+S), the specimen with web opening at maximal moment zone is not less than that without web opening in terms of strength and ductility.

  • PDF

Energy absorption characteristics of diamond core columns under axial crushing loads

  • Azad, Nader Vahdat;Ebrahimi, Saeed
    • Steel and Composite Structures
    • /
    • v.21 no.3
    • /
    • pp.605-628
    • /
    • 2016
  • The energy absorption characteristics of diamond core sandwich cylindrical columns under axial crushing process depend greatly on the amount of material which participates in the plastic deformation. Both the single-objective and multi-objective optimizations are performed for columns under axial crushing load with core thickness and helix pitch of the honeycomb core as design variables. Models are optimized by multi-objective particle swarm optimization (MOPSO) algorithm to achieve maximum specific energy absorption (SEA) capacity and minimum peak crushing force (PCF). Results show that optimization improves the energy absorption characteristics with constrained and unconstrained peak crashing load. Also, it is concluded that the aluminum tube has a better energy absorption capability rather than steel tube at a certain peak crushing force. The results justify that the interaction effects between the honeycomb and column walls greatly improve the energy absorption efficiency. A ranking technique for order preference (TOPSIS) is then used to sort the non-dominated solutions by the preference of decision makers. That is, a multi-criteria decision which consists of MOPSO and TOPSIS is presented to find out a compromise solution for decision makers. Furthermore, local and global sensitivity analyses are performed to assess the effect of design variable values on the SEA and PCF functions in design domain. Based on the sensitivity analysis results, it is concluded that for both models, the helix pitch of the honeycomb core has greater effect on the sensitivity of SEA, while, the core thickness has greater effect on the sensitivity of PCF.

A Study on Eccentric Joint of K-type Gusset-Tube Connection (K형 가셋트-강관 접합부의 편심접합에 관한 연구)

  • Kim, Woo Bum;Kim, Kap Sun;Chung, Soo Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.81-89
    • /
    • 2001
  • Experiments and the parametric based on finite element model were conducted to investigate the behavior and strength of a gussettube connection concerned with eccentricity and selenderness ratio. Because of limitations in loading capacity the specimens were fabricated with 1/3 scale of full size. Of primary interest here are the ultimate strength of connections having eccentricity caused by lateral loads. As a result the effect of eccentricity on the buckling strength was examined and the validity of the finite element model adopted in this study was verified through comparing with test results.

  • PDF

Performance of composite frame consisting of steel beams and concrete filled tubes under fire loading

  • Shariati, Mahdi;Grayeli, Mohammad;Shariati, Ali;Naghipour, Morteza
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.587-602
    • /
    • 2020
  • In recent years, the composite columns have been widely used in the structures. These columns are mainly used to construct the structures with a large span and high floor height. Concrete filled tubes (CFTs) are a type of composite column, which are popular nowadays due to their numerous benefits. The purpose of this study is to investigate such frames at elevated temperatures. The method used in this research is based on section 2.2 of Eurocode 4. First, for the verification purpose, a comparison was made between the experimental results and the numerical model of the concrete filled tube. Then a composite frame was analyzed under fire temperature with different parameters. The results showed that the failure time decreased with increasing the friction of different models. Moreover, investigation of the concrete moisture content revealed that an increase in the concrete moisture content from 3% to 10% led to extended failure time for different models. For instance, in the second frame model, the failure time has increased up to 8%.