• 제목/요약/키워드: Steel-plate reinforcement

검색결과 188건 처리시간 0.018초

Mathematical Models for Optimal Bead Geometry for GMA Welding Process

  • Park, C.E.;Li, C.S.;Kim, I.S.
    • International Journal of Korean Welding Society
    • /
    • 제3권1호
    • /
    • pp.8-16
    • /
    • 2003
  • A major concern in Gas Metal Arc (GMA) welding process is the determination of welding process variables such as wire diameter, gas flow rate, welding speed, arc current and welding voltage and their effects on the desired weld bead dimensions and shape. To successfully accomplish this objective, 81 welded samples from mild steel AS 1204 flats adopting the bead-on-plate technique were employed in the experiment. The experimental results were used to develop a mathematical model to predict the magnitude of bead geometry as follows; weld bead width, weld bead height, weld bead penetration depth, weld penetration shape factor, weld reinforcement shape factor, weld bead total area, weld bead penetration area, weld bead reinforcement area, weld bead dilution, length of weld bead penetration boundary and length of weld bead reinforcement boundary, and to establish the relationships between weld process parameters and bead geomery. Multiple regression analysis was employed for investigating and modeling the GMA process and significance test techniques were applied for the interpretation of the experimental data.

  • PDF

캡플레이트를 이용한 장스팬용 춤이 깊은 데크의 휨성능 개선 (Improvement of Flexural Performance for Deep-Deck Plate using Cap Plate)

  • 박기연;남윤선;최영환;김영호;최성모
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.555-567
    • /
    • 2013
  • 철골구조의 층고를 절감을 위해 유럽을 중심으로 춤이 깊은 데크를 사용한 슬림플로어 공법이 개발되어 적용되고 있다. 국내에서도 장스팬과 층고절감을 요구하는 건물이 증가하고 있지만 7m이상 장스팬에 춤이 깊은 데크를 적용 시 과도한 처짐에 의한 사용성 문제를 초래한다. 따라서 본 연구는 장스팬에 적용되는 춤이 깊은 데크의 콘크리트 타설시 처짐의 사용성 및 개방형 단면의 불안정성에 의한 휨비틀림 등의 문제를 개선하는 방안으로 Cap형태의 plate(이하 '캡 플레이트')를 두가지 형태(Flat, Hat)로 개발하고 보강 길이와 위치의 최적화를 이론적 계산을 통해 도출하였다. 이 캡플레이트를 춤이 깊은 데크의 골상부에 일정 간격으로 설치하여 상부 개방형 불안전성을 극복하고 단면의 강성을 증대시켜 중앙부 처짐을 제어하고자 한다. 캡 플레이트의 설치위치와 보강길이에 따른 휨서능 개선의 효과를 해석과 실험을 통해 검증하고자 한다.

합성형 교량에서 전단연결재에 대한 정적실험 및 강도식의 제안 (Static Test and Suggestion of Shear Strength Equation on Shear Studs in Composite Bridge)

  • 이성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.43-50
    • /
    • 2018
  • 본 연구에서는 강주형과 바닥판의 합성에 사용되는 전단연결재에 대한 연구를 위해 세계 각국에서 사용되는 설계기준과 연구사례를 분석하고 교량 바닥판에 작용하는 각종 수직하중으로 인해 강주형과 콘크리트 슬래브의 접촉면에 발생하는 수평방향의 전단력을 전달하는 이 연결재를 설치한 밀어내기 시험체에 대하여 전단실험을 수행하였으며, 이 시험을 통하여 철근 대신 FRP 철근이 배치된 Steel strap 바닥판의 전단열재 평가식을 제안하였다. 본 연구에서의 제안식은 도로교설계기준의 전단연결재 허용강도 대비 약 3배의 안전율을 가지고 있으며, 기존의 DIN 기준과 Viest 평가식과 비교하면 5%정도의 오차로 유사한 결과를 보여주었다.

Experimental study on RC beams externally bonded by CFRP sheets with and without end self-locking

  • Chaoyang Zhou;Yanan Yu;Chengfeng Zhou;Xuejun He;Yi Wang
    • Steel and Composite Structures
    • /
    • 제48권5호
    • /
    • pp.599-610
    • /
    • 2023
  • To avoid debonding failure, a novel type of hybrid anchorage (HA) is proposed in this study that uses a slotted plate to lock the ends of the fiber-reinforced polymer (FRP) sheet in addition to the usual bonding over the substrate of the strengthened member. An experimental investigation was performed on three groups of RC beams, which differed from one another in either concrete strength or steel reinforcement ratio. The test results indicate that the end self-locking of the CFRP sheet can improve the failure ductility, ultimate capacity of the beams and its utilization ratio. Although intermediate debonding occurred in all the strengthened beams, it was not a fatal mode of failure for the three specimens with end anchorage. Among them, FRP rupture occurred in the beam with higher concrete strength and lower steel reinforcement ratio, whereas the other two failed by concrete crushing. The beam strengthened by HA obtained a relatively high percentage of increase in ultimate capacity when the rebar ratio or concrete strength decreased. The expressions in the literature were inspected to calculate the critical loads at intermediate debonding, FRP rupturing and concrete crushing after debonding for the strengthened beam. Then, the necessity of further research is addressed.

Evaluation of The Moment Resistance Joint Strength of Larch Glulam Using Glass Fiber Reinforced Wood Plate

  • Song, Yo-Jin;Jung, Hong-Ju;Park, Hyun-Ho;Lee, Hak-Young;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.571-578
    • /
    • 2014
  • As a way of developing wooden joint development, a glass fiber reinforced wood plate was manufactured to replace a steel plate. Also, the fracture toughness was evaluated. Through application to a cantilever-type specimen made of a column and a beam, the moment resistance performance was evaluated. For the fracture toughness specimen of the wood plate, 12 types were manufactured by varying the combination of a main member (veneer and plywood) and reinforcement (glass fiber sheet and glass fiber cloth). The results of the fracture toughness test indicated that the 5% yield load of the specimen using plywood was 18% higher than that of the specimen using veneer, and that the specimen reinforced by inserting glass fiber sheets between testing materials (Type-3-PS) had the highest average 5% yield load 4841 N. Thus, a moment resistance strength test was performed by applying Type-3-PS to a column-beam joint. The results of the test indicated that compared to the specimen using a steel plate and a drift pin (Type-A), the maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a drift pin (Type-B) was 0.79; and that a rupture occurred in the wood plate due to high stiffness of the drift pin. The maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a glass fiber reinforced wooden laminated pin (Type-C) was 0.67, which showed low performance. However, unlike Type-A, a ductile fracture occurred on Type-C, and the load gradually decreased even after the maximum moment.

무도상 철도판형교의 동적응답특성 및 보강방안 (Dynamic Response and Reinforcement of the Railway Plate Girder Bridges)

  • 황원섭;조은상;오지택;김현민
    • 한국강구조학회 논문집
    • /
    • 제19권3호
    • /
    • pp.281-290
    • /
    • 2007
  • 본 논문에서는 상용유한요소해석 프로그램을 이용하여 12형 무도상 판형교를 보요소의 형상함수를 이용한 시간하중함수를 열차의 표준하중선도에 적용하여 해석하였다. 또한 Klingel의 sine운동을 적용하여 횡방향 거동특성을 모사하였다. 실제 운행한 상시운행열차 및 증속 실험의 자료와 해석프로그램의 변위, 가속도 자료를 비교하여 해석프로그램 및 해석기법의 타당성을 검토하였다. 그 결과 수평변위와 수직변위의 시간이력이 실제 계측된 자료를 적정수준으로 반영하였다. 6가지 보강모델의 수직 및 수평방향의 변위, 가속도의 보강효과를 살펴보았으며 상부 수평브레이싱 시스템을 하부에 도입한 RF-1모델과 판을 보강한 RF-3모델이 중량제한과 시공성 등을 고려할 때 가장 효과적인 보강방법으로 판단된다.

철근 콘크리트 벽과 강판 콘크리트 벽이 수직으로 만나는 이질접합 구조물의 면외 휨 거동 특성 연구 (A Study on Out-of-Plane Flexural Behavior of the Structure with a Vertical Plane Connection between a Reinforced Concrete Wall and a Steel Plate Concrete Wall)

  • 황경민;이경진;함경원;김원기
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.93-102
    • /
    • 2013
  • 본 연구에서는 철근콘크리트 벽과 강판 콘크리트 벽이 서로 수직면의 이질접합 형태로 만나는 벽의 면외 휨 거동 특성을 검토하기 위하여, L형 실험체를 제작하고 휨 실험을 수행하였다. 실험 시, 실험체의 동적특성을 확인하기 위하여 Push 및 Pull 하중을 반복하는 싸이클 하중을 구현하고자 하였다. Push 하중에 의한 실험 결과, 실험체의 공칭강도를 초과하는 휨 성능을 발휘하였으며, 이에 따라 설계에 적용된 수직철근의 미겹침 이음길이의 타당성을 확인할 수 있었다. 한편, Pull 하중 가력 시에는 수직철근이 최대 내력을 발휘하기 전에 접합부 콘크리트에서 전단 파괴 거동이 나타나, 이에 대한 보강이 필요함을 확인하였다.

마이크로 강섬유 콘크리트를 적용한 연속 합성슬래브의 휨 및 균열 저항성능 (Flexural Performance and Cracking Resistance of Continuous Composite Slab using Micro Steel Fibers)

  • 황현종;박홍근;홍건호;김갑득;최세진
    • 콘크리트학회논문집
    • /
    • 제27권4호
    • /
    • pp.387-397
    • /
    • 2015
  • 본 연구에서는 시공성 향상을 위해 데크플레이트와 비정질강섬유 콘크리트를 적용하여 현장 무배근 슬래브 시스템을 연구하였다. 제안한 슬래브에서는 온도철근을 강섬유로 대체하였다. 본 연구는 연속슬래브에서 상부 철근이 연속되지 않는 경우 슬래브의 상부 균열 제어를 주로 고려하였다. 실험변수로 비정질강섬유 혼입량, 강섬유 종류, 데크플레이트 종류, 연속구간의 철근 이음을 고려하였으며, 수직하중을 받는 2경간 슬래브를 실험하였다. 슬래브의 균열저항성능을 평가하기 위하여 연속슬래브의 하중에 따른 균열폭을 계측하였다. 실험결과, 상부 이음철근을 사용하지 않더라도 합성슬래브의 높은 휨강성으로 인하여 균열을 억제할 수 있는 것으로 나타났다.

패널존과 점성감쇠기를 고려한 강골조 구조물의 내진 설계 모델 (Seismic Design of Steel Frame Model Considering the Panel Zone and Viscous Dampers)

  • 박순응;이택우
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.87-94
    • /
    • 2020
  • The present study is aimed to calculate the optimal damping according to the seismic load on the structure with a non-seismic design to perform structure analysis considering the deformation of structural joint connection and panel zone; to develop design program equipped with structural stability of the steel frame structures reinforced with the panel zone and viscous dampers, using the results of the analysis, in order to systematically integrate the seismic reinforcement of the non-seismic structures and the analysis and design of steel frame structures. The study results are as follows: When considering the deformation of the panel zone, the deformation has been reduced up to thickness of the panel double plate below twice the flange thickness, which indicates the effect of the double plate thickness on the panel zone, but the deformation showed uniform convergence when the ration is more than twice. The SMRPF system that was applied to this study determines the damping force and displacement by considering the panel zone to the joint connection and calculating the shear each floor for the seismic load at the same time. The result indicates that the competence of the damper is predictable that can secure seismic performance for the structures with non-seismic design without changing the cross-section of the members.

연속 캡 형상 전단연결재의 전단 내력에 관한 실험 연구 (Experimental Study on the Shear Capacity of Continuous Cap-Type Shear Connector)

  • 오명호;김영호;정석창;김명한
    • 한국공간구조학회논문집
    • /
    • 제19권2호
    • /
    • pp.91-99
    • /
    • 2019
  • The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the continuous cap-type shear connector. Existing formulas for the elevation of shear connector capacity were investigated on the basis of test results. The shear capacities of continuous cap-type shear connectors distinctly declined as the diameters of side-hole in the shear connector increased. The rebars through side-hole for the transverse reinforcement improved the shear capacity of continuous cap-type connector by 20 to 30 percent. It was not feasible to obtain the appropriate capacity values of continuous cap-type shear connectors made of thin steel plate like those of in this study, using the existing formulas. The new formula for reflecting the shear strength of penetrative bars was proposed based on the shear equation of Eurocode 4. The slip capacities of continuous cap-type shear connectors were shown to exceed the limit value of 6mm for the sufficiently ductile behavior.