• Title/Summary/Keyword: Steam pressure

Search Result 900, Processing Time 0.033 seconds

양극산화와 열수처리한 니오비움 금속의 표면특성 (Surface Characterization of Anodized and Hydrothermal Treated Niobium Metal)

  • 원대희;김영순;윤동주;이민호;배태성
    • 한국재료학회지
    • /
    • 제15권2호
    • /
    • pp.134-138
    • /
    • 2005
  • This study was performed to investigate the surface properties of electrochemically oxidized pure niobium by anodic oxide and hydrothermal treatment technique. Niobium specimens of $10mm\times10mm\times1.0mm$ in dimension were polished sequentially from $\#600,\;\#800,\;\#1000$ emery paper. The surface of pure niobium sperimens was anodized in an electrolytic solution that was dissolved calcium and phosphate in water. The electrolytic voltage was set in the range of 250 V and the current density was $10mA/cm^2$. The specimen was hydrothermal treated in high-pressure steam at $300^{\circ}C$ for 2 hours using an autoclave. And all specimens were immersed in the in the Hanks' solution nth pH 7.4 at $37^{\circ}C$ for 30 days. The surface of specimen was characterized by surface roughness, scanning electron microscope(SEM), energy dispersion X-ray analysis(EDX), X-ray photoemission spectroscopy(XPS) test. The value of surface roughness was the highest in the anodized sample and $0.41{\pm}0.04\;{\mu}m$. The results of the SEM observation show that oxide layers of the multi porosity in the anodized sample were piled up on another, and hydroxyapatite crystal was precipitate from the surface of the hydrothermal treated sample. In the XPS analysis, O, Nb, C peak and small amounts of N peak were found in the polished specimens while Ca and P peak in addition to O, Nb, C and peak were observed in the hydrothermal treated sample.

양극산화와 열수처리한 Ti-6Al-7Nb 합금의 표면 특성 (Surface Characteristics of Anodized and Hydrothermally-Treated Ti-6Al-7Nb Alloy)

  • 김문영;송광엽;배태성
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.33-42
    • /
    • 2005
  • This study was performed to investigate the surface properties and in vitro biocompatibility of electrochemically oxidized Ti-6Al-7Nb alloy by anodic spark discharge technique. Discs of Ti-6Al-7Nb alloy of 20 mm in diameter and 2 mm in thickness were polished sequentially from #300 to 1000 SiC paper, ultrasonically washed with acetone and distilled water for 5 min, and dried in an oven at $50^{\circ}C$ for 24 hours. Anodizing was performed using a regulated DC power supply. The applied voltages were given at 240, 280, 320, and 360 V and current density of $30mA/cm^2$. Hydrothermal treatment was conducted by high pressure steam at $300^{\circ}C$ for 2 hours using a autoclave. Samples were soaked in the Hanks' solution with pH 7.4 at $36.5^{\circ}C$ during 30 days. The results obtained were summarized as follows; 1. The oxide films were porous with pore size of $1{\sim}5{\mu}m$. The size of micropores increased with increasing the spark forming voltage. 2. The main crystal structure of the anodic oxide film was anatase type as analyzed with thin-film X-ray diffractometery. 3. Needle-like hydroxyapatite (HA) crystals were observed on anodic oxide films after hydrothermal treatment at $300^{\circ}C$ for 2 hours. The precipitation of HA crystals was accelerated with increasing the spark forming voltage. 4. The precipitation of the fine asperity-like HA crystals were observed after being immersed in Hanks' solution at $37^{\circ}C$. The precipitation of HA crystals was accelerated with increasing the spark forming voltage and the time of immersion in Hanks' solution. 5. The Ca/P ratio of the precipitated HA layer was equivalent to that of HA crystal as increasing the spark forming voltage and the time of immersion in Hanks' solution.

양극산화처리를 통한 다공성 임플랜트 표면의 표면거칠기 증대에 대한 연구 (STUDY ON THE ENHANCING MICRO-ROUGHNESS OF POROUS SURFACED DENIAL IMPLANT THROUGH ANODIZATION)

  • 윤태호;송광엽
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.617-627
    • /
    • 2006
  • Statement of problem: HA has been used as a coating material on Ti implants to improve osteoconductivity. However. it is difficult to form uniform HA coatings on implants with complex surface geometries using a plasma spraying technique. Purpose : To determine if Ti6Al4V sintered porous-surfaced implants coated with HA sol-gel coated and hydrothermal treated would accelerate osseointegration. Materials and Methods : Porous implants which were made by electric discharge were used in this study. Implants were anodized and hydrothermal treatment or HA sol-gel coating was performed. Hydrothermal treatment was conducted by high pressure steam at $300^{\circ}C$ for 2 hours using a autoclave. To make a HA sol, triethyl phosphite and calcium nitrate were diluted and dissolved in anhydrous ethanol and mixed. Then anodized implant were spin-coated with the prepared HA sols and heat treated. Samples were soaked in the Hanks solution with pH 7.4 at $37^{\circ}C$ for 6 weeks. The microstructure of the specimens was observed with a scanning electron microscope (SEM), and the composition of the surface layer was analyzed with an energy dispersive spectroscope (EDS). Results : The scanning electron micrographs of HA sol-gel coated and hydrothermal treated surface did not show any significant change in the size or shape of the pores. After immersion in Hanks' solution the precipitated HA crystals covered macro- and micro-pores The precipitated Ca and P increased in Hanks' solution that surface treatment caused increased activity. Conclusion : This study shows that sol-gel coated HA and hydrothermal treatment significantly enhance the rate of HA formation due to the altered surface chemistry.

선박동력용 SOFC/GT/ST 하이브리드시스템의 성능 평가에 관한 시뮬레이션 (Performance Analysis of Hybrid SOFC/GT/ST System for Marine Power Applications)

  • 이경진;오진숙;김선희;오세진;임태우;김종수;이재현;박상균;김만응;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.40-50
    • /
    • 2012
  • 폐열의 활용은 연료전지시스템의 효율의 제고에 중요하다. SOFC/GT/ST 하이브리드시스템은 연료전지시스템 폐열의 전력화에 가스터빈 및 증기터빈을 활용하는 방식이다. 본 논문은 SOFC/GT/ST 하이브리드시스템에 대한 스택의 작동온도와 전류밀도, 가스터빈의 압력비가 시스템의 성능에 미치는 영향 등을 시뮬레이션을 통하여 검토한 것이다. 그 결과로 SOFC/GT/ST 하이브리드시스템은 단독 SOFC시스템과 비교하여 효율의 급격한 변화를 완화시키며 또한 효율을 크게 제고시키고 있음을 확인하였다.

고상반응식을 이용한 석회-석영의 수열반응속도와 반응메카니즘 (Hydrothermal Kinetics and Mechanisms of Lime and Quartz Used Solid State Reaction Equations)

  • 임굉
    • 공학논문집
    • /
    • 제3권1호
    • /
    • pp.223-233
    • /
    • 1998
  • 고상반응식을 이용한 석회와 석영과의 수열반응속도 및 반응메카니즘에 관하여 연구하였다. 출발물질로 석영과 수산화칼슘 CaO/$SiO_2$몰비 0.8-1.0로 혼합하고 $180-200^{\circ}C$, 0.5-8시간동안 포화증기압하에서 오토클레이브로 수열반응을 행하였다. 수열반응속도는 총 석회의 양과 총 석영의 양에 대한 미반응 석회의 양과 미반응 석영의 양의 비로 구하였다. 반응속도는 Jander의 식 $[1-(1-\alpha)^{1/3}]^N=Kt$를 이용하여 얻은 결과, 석회의 반응속도는 N=1로서 주로 용해속도에 의해 지배되고 석영의 반응속도는 $N\risingdotseq2$로서 확산에 의해 주로 지배된다. 규산칼슘수화물계의 수열반응속도는 반응물 입자주위에 형성된 생성물층을 통한 물질전달에 의해 율속되는 것으로 추정되고 전체 수열반응의 속도식은 대략 $N=1-2$로서 경계층으로부터 확산에 의해 율속과정으로 전환된다.

  • PDF

원자력 발전 주기기 제작에 적용되는 용접공정 (Welding process for manufacturing of Nuclear power main components)

  • 정인철;김용재;심덕남
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2010년도 춘계학술발표대회 초록집
    • /
    • pp.43-46
    • /
    • 2010
  • As the nuclear power plant has been constructed continuously for several decades in Korea, the welding technology for components manufacturing and installation has been improved largely. Standardization for weld test and qualification was also established systematically according to the concerned code. The welding for the main components requires the high reliability to keep the constant quality level, which means the repeatability of weld quality. Therefore the weld process qualified by thorough test and evaluation is able to be applied for manufacturing. Narrow gap SAW and GTAW process are usually applied for girth seam welding of pressure vessel like Reactor vessel, steam generator, and etc. For the surface cladding with stainless steel and Inconel material, strip welding process is mainly used. Inside cladding of nozzles is additionally applied with Hot wire GTAW and semi-auto welding process. Especially the weld joint having elliptical weld line on curved surface needs a specialized weld system which is automatically rotating with adjusting position of the head torch. The small sized pipe, tube, and internal parts of reactor vessel requests precise weld processes like an automatic GTAW and electron beam welding. Welding of dissimilar materials including Inconel690 material has high possibility of weld defects like a lack of fusion, various types of crack. To avoid these kinds of problem, optimum weld parameters and sequence should be set up through the many tests. As the life extension of nuclear power plant is general trend, weld technologies having higher reliability is required gradually. More development of specialized welding systems, weld part analysis and evaluation, and life prediction for main components should be taken into a consideration extensively.

  • PDF

양극산화와 열수처리한 순수 니오비움 금속의 생체활성 평가 (Evaluation of Biocompatibility of Anodized and Hydrothermally Treated Pure Niobium Metal)

  • 원대희;최운재;이민호;배태성
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.79-88
    • /
    • 2005
  • This study was performed to investigate the surface properties of electrochemically oxidized pure niobium by anodic oxide and hydrothermal treatment technique. Niobium specimens of $10\times10mm$ in dimension were polished sequentially from #600, #800, #1000 emery paper. The surface pure niobium specimens were anodized in an electrolytic solution that was dissolved calcium and phosphate in water. The electrolytic voltage was set in the range of 250 V and the current density was 10 $mA/cm^2$. The specimen was hydrothermal treated in high-pressure steam at 300$^{\circ}C$ for 2 hours using an autoclave. Then, specimens were immersed in the Hanks' solution with pH 7.4 at 37$^{\circ}C$ for 30 days. The surface of specimen was characterized by scanning electron microscope(SEM), energy dispersive X-ray microanalysis(EDX), potentiostat/galvanostat test, and cytotoxicity test. The results obtained was summarized as follows; According to the result of measuring corrosion behavior at 0.9% NaCl, corrosion resistance was improved more specimens treated with anodic oxide than in hydrothermal treated ones. The multi-porous oxide layer on surface treated through anodic oxidation showed a structure that fine pores overlap one another, and the early precipitation of apatite was observed on the surface of hydrothermal treated samples. According to the result of EDX after 30 days deposition in Hanks' solution, Ca/P was 1.69 in hydrothermal treated specimens. In MTT test, specimens treated through anodic oxidation and hydrothermal treated ones showed spectrophotometer similar to that of the control group. Thus no significant difference in cytotoxicity was observed (P>0.05).

  • PDF

SEWGS 공정을 위한 유동층 반응기에서 내부 삽입물의 모양이 WGS 촉매의 CO 전환율에 미치는 영향 (Effect of Bed Insert Geometry on CO Conversion of WGS Catalyst in a Fluidized Bed Reactor for SEWGS Process)

  • 류호정;김하나;이동호;진경태;박영철;조성호
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.535-542
    • /
    • 2013
  • To enhance the performance of SEWGS system by holding the WGS catalyst in a SEWGS reactor using bed inserts, effect of bed insert geometry on CO conversion of WGS catalyst was measured and investigated. Small scale fluidized bed reactor was used as experimental apparatus and tablet shaped WGS catalyst and sand particle were used as bed materials. The cylinder type and the spring type bed inserts were used to hold the WGS catalysts. The CO conversion of WGS catalyst with the change of steam/CO ratio was determined based on the exit gas analysis. Moreover, gas flow direction was confirmed by bed pressure drop measurement for each case. The measured CO conversion using the bed inserts showed high value comparable to previous results even though at low catalyst content. Most of input gas flowed through the bed center side when we charged tablet type catalyst into the cylinder type bed insert and this can cause low $CO_2$ capture efficiency because the possibility of contact between input gas and $CO_2$ absorbent is low in this case. However, the spring type bed insert showed good reactivity and good distribution of gas, and therefore, the spring type bed insert was selected as the best bed insert for SEWGS process.

Saccharomyces 속(屬) 및 Bacillus 속(屬)을 접종(接種)한 한국재래식(韓國在來式)고추장의 향기성분동정(香氣成分同定) (Identification of Flavor Components in Korean Ordinary Kochujang Inoculated with Bacillus sp. and Saccharomyces sp.)

  • 안철우;성낙계
    • 한국식품영양과학회지
    • /
    • 제17권1호
    • /
    • pp.1-5
    • /
    • 1988
  • 한국재래식(韓國在來式) 고추장의 효소숙성과정중(酵素熟成過程中), 향기성분생성(香氣成分生成)에 주(主)로 관여(關與)하는 Saccharomyces 속(屬) 1 주(株) Bacillus 속(屬) 3 주(株)를 각각(各各) 접종(接種)하여 담근, 고추장의 향기성분(香氣成分)을 동정(同定)한 결과(結果)를 요약(要約)하면 다음과 같다. Saccharomyces sp. 는 tetrahydro geroniol, methoxy acecoptenone 및 myrtanal의 생성(生咸)에 주(主)로 관여(關與)하며 Bacillus sp. B-1과 Bacillus sp. B-2는 furfuryl-n-butyrate, 그리고 Bacillus sp. B-3는 n-propylbenzene 의 생성(生成)에 주(主)로 관여(關與)하는것으로 밝혀 졌다.

  • PDF

유도가열용 고주파 공진형 인버터를 이용한 과열증기 발생장치 개발에 관한 연구 (A Study on the Development of Superheater Using High-Frequency Resonant Inverter for Induction Heating)

  • 신대철;권혁민;김기환;김용주
    • 전력전자학회논문지
    • /
    • 제9권2호
    • /
    • pp.119-125
    • /
    • 2004
  • 본 논문에서는 간접 유도가열 되는 보일러 시스템과 주파수 범위가 20〔KHz〕에서 50〔KHz〕사이에서 작동되는 전압형 직렬공진 고주파인버터를 이용하여 열 기체를 발생시키는 전압형 공진형 인버터에 관하여 설명하였다. 얇은 스텐레스 판재가 서로 스폿 용접되어 연결되어있고 기포성 적층형 충진발열체로 특수하게 설계된 유도 가열기는 외부에 워크 코일로 감겨져 있는 불소수지계의 절연용기 안에 삽입되어있다. 이 워크 코일은 공진형인버터와 연결되어 있으며 유도가열기를 통해 흐르는 관 유체를 1단가열부에서 저압의 포화증기를 2단가열부에서 열방사성 증발유체를 생성하는 본 시스템의 성능 및 효용성을 실용적인 측면에서 논의하고 평가한다.