• Title/Summary/Keyword: Steam Generator Chemical Cleaning

Search Result 9, Processing Time 0.023 seconds

Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments (고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향)

  • Kwon, Hyuk-chul
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.

Analysis of Chemical Cleaning for the Top-of-Tubesheet of NPP's Steam Generator (원전 증기발생기 관판 상단 화학세정 결과 분석)

  • Lee, Han-Chul;Sung, Ki-Bang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2043-2048
    • /
    • 2013
  • OPR-1000 CE Steam Generator, of which tube material is composed of Alloy-600 HTMA in nuclear power plant, secondary side is generated ODSCC(Outside Diameter Stress Corrosion Cracking) due to the accumulated sludge. ODSCC is centered around the tube sheet and is being affected depending on the height of the sludge. Chemical cleaning was carried out for a top-of-the-tube sheet(TTS) of Steam Generator in order to decrease corrosive condition of the secondary side of Steam Generator tubes and suppress the occurrence of stress corrosion cracking. The amount of sludge removal was 259.2kg. The height of the accumulated sludge was reduced from 0.71 to 0.34 inches. Corrosion rate as the maximum 2.34 mils was satisfied to within EPRI (Electric Power Research Institute) recommendation(10 mils).

A Study on the Chemical Cleaning Process and Its Qualification Test by Eddy Current Testing

  • Shin, Ki Seok;Cheon, Keun Young;Nam, Min Woo;Min, Kyong Mahn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.511-518
    • /
    • 2013
  • Steam Generator (SG) tube, as a barrier isolating the primary coolant system from the secondary side of nuclear power plants (NPP), must maintain the structural integrity for the public safety and their efficient power generation. So, SG tubes are subject to the periodic examination and the repairs if needed so that any defective tubes are not in service. Recently, corrosion related degradations were detected in the tubes of the domestic OPR-1000 NPP, as a form of axially oriented outer diameter stress corrosion cracking (ODSCC). According to the studies on the factors causing the heat fouling as well as developing corrosion cracking, densely scaled deposits on the secondary side of the SG tubes are mainly known to be problematic causing the adverse impacts against the soundness of the SG tubes [1]. Therefore, the processes of various cleaning methods efficiently to dissolve and remove the deposits have been applied as well as it is imperative to maintain the structural integrity of the tubes after exposing to the cleaning agent. So qualification test (QT) should be carried out to assess the perfection of the chemical cleaning and QT is to apply the processes and to do ECT. In this paper, the chemical cleaning processes to dissolve and remove the scaled deposits are introduced and results of ECT on the artificial crack specimens to determine the effectiveness of those processes are represented.

DETECTION OF ODSCC IN SG TUBES DEPENDING ON THE SIZE OF THE CRACK AND ON THE PRESENCE OF SLUDGE DEPOSITS

  • Chung, Hansub;Kim, Hong-Deok;Kang, Yong-Seok;Lee, Jae-Gon;Nam, Minwoo
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.869-874
    • /
    • 2014
  • It was discovered in a Korean PWR that an extensive number of very short and shallow cracks in the SG tubes were undetectable by eddy current in-service-inspection because of the masking effect of sludge deposits. Axial stress corrosion cracks at the outside diameter of the steam generator tubes near the line contacts with the tube support plates are the major concern among the six identical Korean nuclear power plants having CE-type steam generators with Alloy 600 high temperature mill annealed tubes, HU3&4 and HB3~6. The tubes in HB3&4 have a less susceptible microstructure so that the onset of ODSCC was substantially delayed compared to HU3&4 whose tubes are most susceptible to ODSCC among the six units. The numbers of cracks detected by the eddy current inspection jumped drastically after the steam generators of HB4 were chemically cleaned. The purpose of the chemical cleaning was to mitigate stress corrosion cracking by removing the heavy sludge deposit, since a corrosive environment is formed in the occluded region under the sludge deposit. SGCC also enhances the detection capability of the eddy current inspection at the same time. Measurement of the size of each crack using the motorized rotating pancake coil probe indicated that the cracks in HB4 were shorter and substantially shallower than the cracks in HU3&4. It is believed that the cracks were shorter and shallower because the microstructure of the tubes in HB4 is less susceptible to ODSCC. It was readily understood from the size distribution of the cracks and the quantitative information available on the probability of detection that most cracks in HB4 had been undetected until the steam generators were chemically cleaned.

Fenton Degradation of Highly Concentrated Fe(III)-EDTA in the Liquid Waste Produced by Chemical Cleaning of Nuclear Power Plant Steam Generators (펜톤 반응을 이용한 원전 증기발생기 화학세정 폐액의 고농도 Fe(III)-EDTA 분해)

  • Jo, Jin-Oh;Mok, Young Sun;Kim, Seok Tae;Jeong, Woo Tae;Kang, Duk-Won;Rhee, Byong-Ho;Kim, Jin Kil
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.552-556
    • /
    • 2006
  • An advanced oxidation process catalyzed by iron ions in the presence of hydrogen peroxide, the so-called Fenton's reaction, has been applied to the treatment of steam generator chemical cleaning waste containing highly concentrated iron(III)- ethyl-enediaminetetraaceticacid (Fe(III)-EDTA) of 70000 mg/L. The experiments for the degradation of Fe(III)-EDTA were carried out not only with a simulated waste, but also with the real one. The effect of pH and the amount of hydrogen peroxide added to the waste on the degradation was examined, and the results were discussed in several aspects. The optimal pH to maximize the degradation efficiency was dependent on the amount of hydrogen peroxide added to the waste. i.e., when the amount of hydrogen peroxide was different, maximum degradation efficiency was obtained at different pH's. The optimal amount of hydrogen peroxide relative to that of Fe(III)-EDTA was found to be 24.7 mol ($H_{2}O_{2}$)/mol (Fe(III)-EDTA) at pH around 9.

Steam Generator Chemical Cleaning (특집_제25회 한국원자력연차대회 - 증기발생기 화학 세정)

  • D'Annucci, Filippo;Mutius, Bernard
    • Nuclear industry
    • /
    • v.30 no.3
    • /
    • pp.52-56
    • /
    • 2010
  • 증기발생기 2차측 상태는 발전소 운영에 있어 중요한 역할을 수행한다. 기기, 배관 및 열교환기에서 발생되는 침적물은 증기발생기 튜브의 부식 원인이 될 수 있으며, 튜브와 튜브 지지판 사이의 공간을 차단한다. 2차측 침적물에 의한 튜브 파손으로 인해 일부 발전소에서는 강제적으로 발전을 정지하는 사례가 발생하였다. 또한 튜브 지지판의 침적물 축적으로 인해 정상 운전 동안 전력 생산을 감소하게 되는 결과를 초래한 발전소도 있었다. 따라서 증기발생기 2차측 상태 감시와 더불어 증기발생기 부품의 청결 유지는 필수 항목이라 할 수 있다. 웨스팅하우스에서는 증기발생기를 초기 제작 상태로 복구하고 2차측 침적물을 제거하기 위해 EPRI SGOG 증기발생기 화학 세정을 수 년간 이용하고 있다. 본고는 35개 이상의 발전소에서 성공적으로 이용하고 있는 화학 세정 프로세스 개요 및 프로세스를 적용하면서 취득한 경험을 요약한 것이다.

  • PDF

The Study of Effect of EDTA(Ethylenediaminetetraacetic acid) to the defected Ni-Cr-Fe Alloy in the Steam Generator Chemical Cleaning of the Nuclear Power Plant (원전 SG 화학세정 환경에서 EDTA가 결함 Ni-Cr-Fe 합금에 미치는 영향 연구)

  • Gwon, Hyeok-Cheol;Lee, Han-Cheol;Seong, Gi-Bang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.117-118
    • /
    • 2013
  • 증기발생기 화학세정 모사 장치를 이용하여 고농도 화학세정(EPRI/SGOG) 용액인 EDTA(20%)가 인위적으로 제작한 결합 시편에 미치는 영향 평가를 수행하였다. 평가 방법은 세정 전 후 표면 산화막 성분, ECT 분석값 비교, 증기발생기 구성 재료 부식률를 이용하였다. 화학세정 전후 부식률은 A508은 $8.023{\mu}m$, Alloy 600(HTMA)은 $0.007{\mu}m$이며 갈바닉 시편의 경우 $63.193{\mu}m$로 모두 부식 허용치 이내이다. 표면 산화막 성분 및 ECT 분석값 역시 변함이 없었다. 이와 같은 결과로 화학세정 용액인 EDTA는 결함 튜브에 미치는 영향이 없는 것으로 판단된다.

  • PDF

The Voltage-fed High Frequency Resonant Inverter Using Induction Heated Dry Steam Generator

  • Kim, Chil-Ryong;Lee, Jong-Kurl;Jung, Sang-Hwa;Mun, Sang-Pil;Kim, Sang-Don;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.415-418
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction-based fluid beating appliance using voltage-fed type scries capacitor-compensated load resonant high-frequency IGBT inverter with a phase-shifted PWM and a power factor correction schemes. Its operating characteristics in steady-state are illustrated including unique features and evaluated on the basis of its computer simulation and experimental results of 10kw breadboard appliance for hot water producer and superheated steamer. The promising cost effective inverter-fed boiler appliances for electromagnetic induction-heated type fluid-heating in the pipeline systems are proposed for induction-heated boiler, super heat steamer, high temperature water producer, hot gas producer and metal catalyst heating for exhaust gas cleaning in engine, which are more suitable and acceptable for industrial, chemical, and consumer energy utilization for household and business from a practical point of view.

  • PDF