• Title/Summary/Keyword: Steady State Performance

Search Result 1,419, Processing Time 0.027 seconds

A speed controller design for low speed marine diesel engine by the $\mu$-synthesis ($\mu$-설계법에 의한 저속 박용디젤기관의 속도제어기 설계)

  • 정병건;양주호;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.60-70
    • /
    • 1995
  • In the field of marine transportation the energy saving is one of the most important factors for profit. In order to reduce the fuel oil consumption the ship's propulsion efficiency must be increased as much as possible. The propulsion efficiency depends upon a combination of an engine and a propeller. The propeller has better efficiency as lower rotational speed. This situation led the engine manufacturers to design the engine that has lower speed, longer stroke and a small number of cylinders. Consequently the variation of rotational torque became larger than before because of the longer delay-time in the fuel oil injection process and an increased output per cylinder. As this new trends the conventional mechanical-hydrualic governors for engine speed control have been replaced by digital speed controllers which adopted the PID control or the optimal control algorithm. But these control algorithms have not enough robustness to suppress the variation of the delay-time and the parameter pertubation. In this paper we consider the delay-time and the perturbation of engine parameters as the modeling uncetainties. Next we design the controller which has zero offset in steady state engine speed, based on the two-degree-of-freedom control theory and $\mu$-synthesis. Thd validity of the controller is investigated through the response simulation. We use a personal computer and an analog computer as the digital controller and the engine (plant) part respectively. And, we certify that the designed controller maintains its performance even though the engine parameters may vary.

  • PDF

Studies on the Computer Controlled Vibratory Tillage (진동경운(振動耕耘)의 컴퓨터제어(制御)에 관(關)한 연구(硏究))

  • Lee, Ki Myung
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.95-101
    • /
    • 1986
  • A computer-controlled automatic vibratory tillage test equipment which attained minimum draft and power was developed. Three control program modes were developed and tested with this equipment. A computer simulation investigated the control performances of the above modes with the following primary results. 1) All of the three control modes converged to the same steady state when the velocity ratio was kept constant. 2) The control mode in which the blade frequency was twice of the soil shearing frequency (frequency control mode) showed optimum control with minimum draft and power, and also had greatest velocity convergence. 3) Results of the simulations showed the frequency control mode to have achieved the best control performance. The fluctuation of the draft reduction was less than 10% at various cutting depths and soil moistures.

  • PDF

An Adaptive Method For Face Recognition Based Filters and Selection of Features (필터 및 특징 선택 기반의 적응형 얼굴 인식 방법)

  • Cho, Byoung-Mo;Kim, Gi-Han;Rhee, Phill-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.1-8
    • /
    • 2009
  • There are a lot of influences, such as location of camera, luminosity, brightness, and direction of light, which affect the performance of 2-dimensional image recognition. This paper suggests an adaptive method for face-image recognition in noisy environments using evolvable filtering and feature extraction which uses one sample image from camera. This suggested method consists of two main parts. One is the environmental-adjustment module which determines optimum sets of filters, filter parameters, and dimensions of features by using "steady state genetic algorithm". The other another part is for face recognition module which performs recognition of face-image using the previous results. In the processing, we used Gabor wavelet for extracting features in the images and k-Nearest Neighbor method for the classification. For testing of the adaptive face recognition method, we tested the adaptive method in the brightness noise, in the impulse noise and in the composite noise and verified that the adaptive method protects face recognition-rate's rapidly decrease which can be occurred generally in the noisy environments.

A Numerical Study on the Simulation of Power-pack Start-up of a Staged Combustion Cycle Engine (다단연소 사이클 엔진의 파워팩 시동 모사를 위한 해석적 연구)

  • Lee, Sunghun;Jo, Seonghui;Kim, Hongjip;Kim, SeongRyong;Yi, SeungJae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.3
    • /
    • pp.58-66
    • /
    • 2019
  • In this study, the start-up characteristics of a staged combustion engine were analyzed numerically based on relational equation modeling of the entire engine components. The start-up characteristics were extensively analyzed considering the transient period of the total engine system from the start-up sequence till the steady-state of the engine. The performance characteristics of the engine components such as RPM of engine power-pack, chamber pressure and O/F ratio of pre-burner, and mass flow of propellants in the start-up period were investigated. Furthermore, the calculated engine data were compared satisfactorily with the experimental data. Through the comparison of data, successful validation of present engine start-up analysis has been obtained.

Transport of Water through Polymer Membrane in Proton Exchange Membrane Fuel Cells (고분자전해질 연료전지에서 고분자막을 통한 물의 이동)

  • Lee, Daewoong;Hwang, Byungchan;Lim, Daehyun;Chung, Hoi-Bum;You, Seung-Eul;Ku, Young-Mo;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.338-343
    • /
    • 2019
  • The water transport and water content of the electrolyte membrane greatly affect the performance of the membrane in PEMFC(Proton Exchange Membrane Fuel Cell). In this study, the parameters (electroosmotic coefficient, water diffusion coefficient) of polymer membranes for water transport were measured by a simple method, and water flux and ion conductivity were simulated by using a model equation. One dimensional steady state model equation was constructed by using only the electro-osmosis and diffusion as the driving force of water transport. The governing equations were simulated with MATLAB. The electro-osmotic coefficient of $144{\mu}m$ thick polymer membranes was measured in hydrogen pumping cell, the value was 1.11. The water diffusion coefficient was expressed as a function of relative humidity and the activation energy for water diffusion was $2,889kJ/mol{\cdot}K$. The water flux and ion conductivity results simulated by applying these coefficients showed good agreement with the experimental data.

Analysis of a Queueing Model with a Two-stage Group-testing Policy (이단계 그룹검사를 갖는 대기행렬모형의 분석)

  • Won Seok Yang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.4
    • /
    • pp.53-60
    • /
    • 2022
  • In a group-testing method, instead of testing a sample, for example, blood individually, a batch of samples are pooled and tested simultaneously. If the pooled test is positive (or defective), each sample is tested individually. However, if negative (or good), the test is terminated at one pooled test because all samples in the batch are negative. This paper considers a queueing system with a two-stage group-testing policy. Samples arrive at the system according to a Poisson process. The system has a single server which starts a two-stage group test in a batch whenever the number of samples in the system reaches exactly a predetermined size. In the first stage, samples are pooled and tested simultaneously. If the pooled test is negative, the test is terminated. However, if positive, the samples are divided into two equally sized subgroups and each subgroup is applied to a group test in the second stage, respectively. The server performs pooled tests and individual tests sequentially. The testing time of a sample and a batch follow general distributions, respectively. In this paper, we derive the steady-state probability generating function of the system size at an arbitrary time, applying a bulk queuing model. In addition, we present queuing performance metrics such as the offered load, output rate, allowable input rate, and mean waiting time. In numerical examples with various prevalence rates, we show that the second-stage group-testing system can be more efficient than a one-stage group-testing system or an individual-testing system in terms of the allowable input rates and the waiting time. The two-stage group-testing system considered in this paper is very simple, so it is expected to be applicable in the field of COVID-19.

Digital Control System Validation using the Simulator Models for 500MW Standard Type Fossil Power Plant (500MW급 표준화력발전소 시뮬레이터 모델을 이용한 디지털 제어시스템 검증)

  • Suh, Jeong-Kwan;Lee, Myeong-Soo;Hong, Jin-Hyuk
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.3
    • /
    • pp.71-79
    • /
    • 2010
  • The simulator models for 500MW fossil power plant have been developed, and interconnected with the turbine control system to test and validate the digital instrumentation & control (I&C) systems before they are implemented in operating power plants. When the performance of a selected digital I&C system is tested, the corresponding simulator model is replaced by the plant digital I&C systems which is considered as a non-tunable system. The input/out variables of simulator models and control systems were mapped using the LabView in interface systems. This paper describes the interconnection method between the simulator model and the digital I&C system, and summarizes the validation test results performed at the condition of steady-state operation, normal evolution, and malfunction. The integrated validation method of digital I&C systems using the simulator models showed that the simulator can be used as a test bed for the implementation of digital I&C systems in power plants.

Estimation of maximum object size satisfying mean response time constraint in web service environment (웹 서비스 환경에서 평균 응답 시간의 제약조건을 만족하는 최대 객체 크기의 추정)

  • Yong-Jin Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.3
    • /
    • pp.1-6
    • /
    • 2023
  • One of the economical ways to satisfy the quality of service desired by the user in a web service environment is to adjust the size of the object. To this end, this study finds the maximum size of objects that satisfy this constraint when the mean response time is given below an arbitrary threshold for quality of service. It can be inferred that in the steady state of system, the mean response time in the deterministic model by using the round-robin will be the same as that of the queueing model following the general distribution. Based on this, analytical formulas and procedures for finding the maximum object size are obtained. As a service distribution of web traffic, the Pareto distribution is appropriate, so the maximum object size is computed by applying the M/G(Pareto)/1 model and the M/G/1/PS model using exponential distribution as computational experience. Performance evaluation through numerical calculation shows that as the shape parameter in the Pareto distribution increases, the M/G(Pareto)/1 model and M/G/1/PS model have the same maximum object size. The results of this study can be used to environments where objects can be sized for economical web service control.

Basic Analysis of Heat and Mass Transfer Characteristics of Tubular Membrane Humidifier for Proton Exchange Membrane Fuel Cell (이온교환막 연료전지용 원통형 막 가습기의 열 및 물질전달특성 기초 연구)

  • Bae, Ho-June;Ahn, Kook-Young;Lee, Young-Duk;Kang, Sang-Kyu;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.473-480
    • /
    • 2011
  • The proton exchange membrane (PEM) fuel cell system is critically dependent on the humidity, which should be properly maintained over the entire operating range. A membrane humidifier is used for the water management in the PEMFC because of the membrane humidifier's reliable performance and zero parasitic power loss. In the PEMFC system, the membrane humidifier is required to provide appropriate humidity for the design point of the fuel cell. Although the performance of the fuel cell depends on the performance of the humidifier, few studies have provided a systematic analysis of the humidifier. We carry out an experimental analysis of the membrane humidifier using a vapor condensation bottle. The dry air pressure, water flow temperature, and air flow rate were chosen as the operating parameters. The results show that the time constant for the dynamic response of the membrane humidifier is relatively short, but additional analysis should be carried out.

Self-Adaptive Performance Improvement of Novel SDD Equalization Using Sigmoid Estimate and Threshold Decision-Weighted Error (시그모이드 추정과 임계 판정 가중 오차를 사용한 새로운 SDD 등화의 자기적응 성능 개선)

  • Oh, Kil Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.17-22
    • /
    • 2016
  • For the self-adaptive equalization of higher-order QAM systems, this paper proposes a new soft decision-directed (SDD) algorithm that opens the eye patterns quickly as well as significantly reducing the error level in the steady-state when it is applied to the initial equalization stage with completely closed eye patterns. The proposed method for M-QAM application minimized the computational complexity of the existing SDD by the symbol estimated based on the two symbols closest to the observation, and greatly simplified the soft decision independently of the QAM order. Furthermore, in the symbol estimating it increased the reliability of the estimates by applying the superior properties of the sigmoid function and avoiding the erroneous estimation of the threshold function. In addition, the initialization performance was improved when an error is generated to update the equalizer, weighting the symbol decision by the threshold function to the error, resulting in an extension of the range of error fluctuations. As a result, the proposed method improves remarkably the computational complexity and the properties of initialization and convergence of the traditional SDD. Through simulations for 64-QAM and 256-QAM under multipath channel conditions with additive noise, the usefulness of the proposed methods was confirmed by comparing the performance of the proposed 2-SDD and two forms of weighted 2-SDD with CMA.