• Title/Summary/Keyword: Statistical Testing

Search Result 1,201, Processing Time 0.028 seconds

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

Prediction of modulus of elasticity of FA concrete using crushing strength, UPV and RHN values

  • Mohd A. Ansari;M. Shariq;F. Mahdi;Saad S. Ansari
    • Computers and Concrete
    • /
    • v.34 no.1
    • /
    • pp.33-48
    • /
    • 2024
  • This paper presents the detailed experimental and analytical investigation on the evolution of static (Es) and dynamic modulus of elasticity (Ed) of concrete having 0%, 35%, and 50% FA used as partial cement replacement. Destructive and non-destructive tests were conducted on cylindrical specimens to evaluate the compressive strength and MoE of concrete in compression at the age of 28, 56, 90, and 150 days for all mixes. Experimental results show that the concrete having 35% FA achieved compressive strength and MoE similar to plain concrete at the age of 90 days, while 50% FA concrete attained satisfactory compressive strength and MoE at the age of 150 days. The comprehensive statistical analysis has been carried out in two ways on the basis of the experimental results. Firstly, the 28-day crushing strength of plain concrete in compression was used to design the models for the prediction of Es and Ed of fly ash concrete at any age and percentage replacement of FA. Secondly, using the values of UPV and RHN, models have been developed to predict the age or time-dependent Es and Ed of fly ash concrete. These models will be helpful in assessing the Es and Ed of fly ash concrete without knowing the 28-day crushing strength of plain concrete in compression in the laboratory. Hence, the suggested models in the present study will be beneficial in conducting the health assessment of fly ash based concrete structures.

Effects of Influencers' Curator Competences on Reliability and Purchase Intention in Live Commerce: Comparison between Korea and China (라이브 커머스에서 인플루언서의 큐레이터 역량이 신뢰도와 구매의도에 미치는 영향: 한중비교)

  • You Kexin;Yeji Yeon;Cheol Park
    • Journal of Information Technology Services
    • /
    • v.23 no.3
    • /
    • pp.1-16
    • /
    • 2024
  • As the COVID-19 pandemic confirmed the culture of non-face-to-face consumption. In retail commerce, the 'live commerce' market, where sales are made by communicating with customers in the form of live streaming broadcasts, has grown rapidly. Although previous studies have consistently confirmed the phenomenon of "influencers" in society and culture, there is a lack of research on the "sales expertise" of live commerce broadcasters such as Wang Hong in China. In China, "Wang Hong" is short for "Wang Luo Hong Ren", a combination of "Wang Luo", which means the Internet, and "Hong Ren", which means star, and refers to a person who is popular through social platforms and is gaining popularity from many fans. Therefore, this study focuses on Wang Hong's developing "selling expertise" and examines it from the perspective of a shopping curator. In particular, we applied Harold Jarche(2011)'s "Seek-Sense-Share" model to influencers to verify their influence on trust and purchase intention in live commerce. Furthermore, we analyzed the differences between Korea and China.A survey was conducted among live commerce users in Korea and China, and a total of 228 questionnaires were used in the final analysis. Basic statistical analysis was conducted using SPSS and hypotheses were tested using PLS 3.0. The results of the hypothesis testing showed that influencers' curatorial competence "Seek-Sense-Share" had a significant effect on trust, and trust had a positive effect on purchase intention. In addition, there is a significant difference between Korean and Chinese consumers in this relationship.

Disease Testing in Pelvic Pain Patients: Comparison between Ultrasound and Computed Tomography Imaging (골반통 환자의 질환 검사: 초음파와 컴퓨터단층촬영 간의 비교)

  • EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.385-390
    • /
    • 2023
  • The uterus, one of women's reproductive organs, is also closely related to women's health. Among them, hemorrhagic luteal cysts, one of the causes of pelvic pain that women often experience, were observed through CT and ultrasound, and the quality of images was evaluated through quantitative and qualitative evaluations. This study sought to find out whether the test method is more helpful to patients during CT and ultrasound. This study was conducted on 15 adolescent women and 15 adult women(21.31±3.45 average age). The equipment used for filming used EC3-10X (3~10 MHZ) and Philips Mx8000 iCT 256 among Endocavity Probes among Ecube Platinum. After setting a constant ROI on the cyst and the interface as a quantitative analysis method, SNR and CNR values were measured on a 5-point scale based on image quality, lesion clarity, image distortion, clarity of the interface, and motion artifacts (p<0.05). Independent t-test and Mann Whiteny U were performed, and the statistical program used was noted when SPSS (Version 22.0 for windows software package, Chicago, IL, USA) was statistically less than 0.05. Comparing the SNR and CNR values for this experiment, it can be seen that the SNR value was higher in the case of CT images(p<0.05). As a result of the qualitative evaluation, the quality of the image, the clarity of the lesion, the distortion of the image, the clarity of the interface, and the clarity of the boundary were measured on a 5-point scale based on the movement artifact. Comparing each score, CT images scored higher with a finer difference than ultrasound images(p<0.05). In conclusion, both test methods showed excellent results in finding the patient's lesions. However, in quantitative and qualitative evaluations, CT produced higher results in detecting lesions than ultrasound. However, for cyst tests that require continuous observation, ultrasonography, a non-invasive method that is advantageous for patients, will be clinically useful. Therefore, observing the patient's lesions by appropriately distributing these two test methods will provide optimal diagnostic information. These results will be useful for providing clinical basic data and educational materials to CT and US users in the future.

Treatment of Osteoporosis after Hip Fracture: Survey of the Korean Hip Society

  • Jung-Wee Park;Je-Hyun Yoo;Young-Kyun Lee;Jong-Seok Park;Ye-Yeon Won
    • Hip & pelvis
    • /
    • v.36 no.1
    • /
    • pp.62-69
    • /
    • 2024
  • Purpose: To assess current practice in the treatment of osteoporosis in patients who underwent treatment for hip fracture in South Korea. Materials and Methods: A survey of 97 members of the Korean Hip Society, orthopedic hip surgeons who administer treatment for hip fractures in South Korea, was conducted. The survey was conducted for assessment of demographic data and perceptions regarding the management of osteoporosis in patients who have undergone treatment for hip fracture. Analysis of the data was performed using descriptive statistical methods. Results: The majority of participants were between the age of 41 and 50 years, and 74% were practicing in tertiary hospitals. Testing for serum vitamin D levels (82%) was the most commonly performed laboratory test. Calcium and vitamin D were prescribed for more than 80% of patients by 47% and 52% of participants, respectively. Denosumab was the most commonly used first-line treatment option for osteoporosis in hip fracture patients. Bisphosphonate was most often perceived as the cause of atypical femoral fractures, and the most appropriate time for reoperation was postoperative 12 months. Teriparatide was most preferred after cessation of bisphosphonate and only prescribing calcium and vitamin D was most common in high-risk patients for prevention of atypical femoral fracture. Conclusion: The results of this study that surveyed orthopedic hip surgeons showed that most participants followed the current strategy for management of osteoporosis. Because the end result of osteoporosis is a bone fracture, active involvement of orthopedic surgeons is important in treating this condition.

The Reliability and Validity of a Portable Hand-held Spirometer for the Measurement of Various Lung Functions in Healthy Adults

  • Merve Nur Uygun;Jun-Min Ann;Byeong-Hyeon Woo;Hyeon-Myeong Park;Ha-Im Kim;Dae-Sung Park;In-Beom Jeong
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.179-186
    • /
    • 2024
  • Objective: This study aims to assess the reliability and validity of the new hand-held spirometer as a potential substitute for traditional pulmonary function testing (PFT) devices. Design: Cross-sectional study. Methods: In this study, thirty healthy adults underwent spirometry using both the new hand-held spirometer and the MIR spirometer, which is a standard PFT device. Parameters including peak expiratory flow (PEF), forced expiratory volume in one second (FEV1), and forced vital capacity (FVC) were measured and analyzed for validity and reliability. Inter-rater reliability and validity were evaluated through 95% limits of agreement (LOA) and intraclass correlation coefficients (ICC). Statistical analyses, including the Bland-Altman plots and the ICC, were utilized to assess agreement between the two devices. Results: The new hand-held spirometer exhibited a good agreement with intra-class coefficient (ICC [2,1]) ranging 0.762 to 0.956 and 95% LOA of -1.94 to 1.80 when compared with MIR. The test-retest reliability of the hand-held spirometer analyzed using - ICC [2,1] demonstrated a good level of consistency (ICC [2,1] =0.849-0.934). Conclusions: In conclusion, the study aimed to assess the potential of the new hand-held spirometer as a viable alternative to traditional PFT devices, with a specific focus on its reliability and validity in spirometric measurements. The new hand-held spirometer exhibited good test-retest reliability across all measured variables, suggesting its potential as a valid and reliable tool for simultaneous PFT measurements.

Determination of shear wave velocity profiles in soil deposit from seismic piezo-cone penetration test (탄성파 피에조콘 관입 시험을 통한 국내 퇴적 지반의 전단파 속도 결정)

  • Sun Chung Guk;Jung Gyungja;Jung Jong Hong;Kim Hong-Jong;Cho Sung-Min
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.125-153
    • /
    • 2005
  • It has been widely known that the seismic piezo-cone penetration test (SCPTU) is one of the most useful techniques for investigating the geotechnical characteristics including dynamic soil properties. As the practical applications in Korea, SCPTU was carried out at two sites in Busan and four sites in Incheon, which are mainly composed of alluvial or marine soil deposits. From the SCPTU waveform data obtained from the testing sites, the first arrival times of shear waves were and the corresponding time differences with depth were determined using the cross-over method, and the shear wave velocity profiles (VS) were derived based on the refracted ray path method based on Snell's law and similar to the trend of cone tip resistance (qt) profiles. In Incheon area, the testing depths of SCPTU were deeper than those of conventional down-hole seismic tests. Moreover, for the application of the conventional CPTU to earthquake engineering practices, the correlations between VS and CPTU data were deduced based on the SCPTU results. For the empirical evaluation of VS for all soils together with clays and sands which are classified unambiguously in this study by the soil behavior type classification Index (IC), the authors suggested the VS-CPTU data correlations expressed as a function of four parameters, qt, fs, $\sigma$, v0 and Bq, determined by multiple statistical regression modeling. Despite the incompatible strain levels of the down-hole seismic test during SCPTU and the conventional CPTU, it is shown that the VS-CPTU data correlations for all soils clays and sands suggested in this study is applicable to the preliminary estimation of VS for the Korean deposits and is more reliable than the previous correlations proposed by other researchers.

  • PDF

A Study on the Influence of Information Security on Consumer's Preference of Android and iOS based Smartphone (정보보안이 안드로이드와 iOS 기반 스마트폰 소비자 선호에 미치는 영향)

  • Park, Jong-jin;Choi, Min-kyong;Ahn, Jong-chang
    • Journal of Internet Computing and Services
    • /
    • v.18 no.1
    • /
    • pp.105-119
    • /
    • 2017
  • Smartphone users hit over eighty-five percentage of Korean populations and personal private items and various information are stored in each user's smartphone. There are so many cases to propagate malicious codes or spywares for the purpose of catching illegally these kinds of information and earning pecuniary gains. Thus, need of information security is outstanding for using smartphone but also user's security perception is important. In this paper, we investigate about how information security affects smartphone operating system choices by users. For statistical analysis, the online survey with questionnaires for users of smartphones is conducted and effective 218 subjects are collected. We test hypotheses via communalities analysis using factor analysis, reliability analysis, independent sample t-test, and linear regression analysis by IBM SPSS statistical package. As a result, it is found that hardware environment influences on perceived ease of use. Brand power affects both perceived usefulness and perceived ease of use and degree of personal risk-accepting influences on perception of smartphone spy-ware risk. In addition, it is found that perceived usefulness, perceived ease of use, degree of personal risk-accepting, and spy-ware risk of smartphone influence significantly on intention to purchase smartphone. However, results of independent sample t-test for each operating system users of Android or iOS do not present statistically significant differences among two OS user groups. In addition, each result of OS user group testing for hypotheses is different from the results of total sample testing. These results can give important suggestions to organizations and managers related to smartphone ecology and contribute to the sphere of information systems (IS) study through a new perspective.

THE COMPARISON OF RELATIVE RELIABILITY ON BIAXIAL AND THREE POINT FLEXURAL STRENGTH TESTING METHODS OF LIGHT CURING COMPOSITE RESIN (광중합형 레진의 3점 굴곡 강도와 이축 굴곡 강도 측정 방법에 대한 상대적 신뢰도의 비교)

  • Seo, Deog-Gyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.58-65
    • /
    • 2006
  • The possibility of applying a hi-axial flexure strength test on composite resin was examined using three point and hi-axial flexure strength tests to measure the strength of the light-cured resin and to compare the relative reliability using the Weibull modulus. The materials used in this study were light-curing restorative materials, $MICRONEW^{TM},\;RENEW^{(R)}$ (Bisco, Schaumburg, USA). The hi-axial flexure strength measurements used the piston-on-3-ball test according to the regulations of the International Organization for Standardization (ISO) 6872 and were divided into 6 groups, where the radius of the specimens were 12mm (radius connecting the 3-balls: 3.75mm), 16 mm(radius connecting the 3-balls: 5mm), and the thickness were 0.5mm, 1mm, 2mn for each radius. The hi-axial flexure strength of the $MICRONEW^{TM}\;and\;RENEW^{(R)}$ were higher than the three point flexure strength and the Weibull modulus value were also higher in all of the bi-axial flexure strength groups, indicating that the hi-axial strength test is relatively less affected by experimental error. In addition, the 2 mm thick specimens had the highest Weibull modulus values in the hi-axial flexure strength test, and the $MICRONEW^{TM}$ group showed no significant statistical difference (p>0.05). Besides the 2mm $MICRONEW^{TM}$ group, each group showed significant statistical differences (p<0.05) according to the thickness of the specimen and the radius connecting the 3-balls. The results indicate that for the 2mm group, the hi-axial flexure strength test is a more reliable testing method than the three point flexure strength test.

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.