• Title/Summary/Keyword: Static Structural

Search Result 2,343, Processing Time 0.024 seconds

A new base shear equation for reliability-based design of steel frames

  • Hakki Deniz Gul;Kivanc Taskin
    • Earthquakes and Structures
    • /
    • v.27 no.1
    • /
    • pp.31-39
    • /
    • 2024
  • The reliability-based seismic design of steel frames is a complex process that incorporates seismic demand with a structural capacity to attain safe buildings aligned with specified constraints. This paper introduces an efficient base shear force formulation to support the reliability-based design process of steel frames. The introduced base shear force equation combines the seismic demand statistics with the reliability objective to calculate a fictitious base shear force for linear static analysis. By concentrating on the seismic demand and promising to meet a certain level of reliability, the equation converts the reliability-based seismic design problem to a deterministic one. Two code-compliant real-size steel moment frames are developed according to different reliability objectives to demonstrate the competency of the proposed formula. The nonlinear dynamic analysis method is used to assess the seismic reliability of the constructed frames, and the numerical results validate the credibility of the suggested formulation. The base shear force calculation method regarding seismic reliability is the main finding of this study. The ease of use makes this approach a potent tool for design professionals and stakeholders to make rapid risk-informed decisions regarding steel moment frame design.

Experimental and theoretical analysis of electronic musical structures with smart nanoparticles

  • Jing Han;Maryam Shokravi;F. Ming
    • Structural Engineering and Mechanics
    • /
    • v.91 no.4
    • /
    • pp.417-426
    • /
    • 2024
  • Nanotechnology has emerged as a promising avenue for enhancing musical structures. In this study, we analyze the static behavior of laser harp (i.e., electronic musical instrument) reinforced with Zinc Oxide (ZnO) nanoparticles. Leveraging the piezoelectric properties of ZnO nanoparticles, the structure is subjected to an electric field for intelligent control. The electronic musical structure is situated in a foundation with vertical springs and shear modulus constants. We employ the exponential Shear Deformation Beam Theory (ESDBT) to mathematically model the structure. A micro-electro-mechanical model is employed to determine the equivalent properties of the system. By utilizing nonlinear stress-strain relations, energy methods, and Hamilton's principle, we derive the motion equations. The buckling load of the electronic musical beam is calculated using the Difference Quadrature Method (DQM). The primary objective of this study is to present a mathematical model for electronic musical beams and determining the buckling load of the structure and to investigate the influence of nanotechnology and electric fields on its buckling behavior. The buckling is the case when the structure becomes deforms and unstable. Our findings reveal that the application of negative external voltage to the electronic musical structure increases both the stiffness and the buckling load of the musical system. Furthermore, reinforcing the electronic musical structure with ZnO nanoparticles results in an increased buckling load. Notably, the maximum enhancement in the 28-day compressive and tensile strengths of samples containing zinc oxide nanoparticles compared to the control sample resulting in increases of 18.70% and 3.77%, respectively.

Finite element analysis of the behavior of elliptical cracks emanating from the orthopedic cement interface in total hip prostheses

  • Ali Benouis;Mohammed El Sallah Zagane;Abdelmadjid Moulgada;Murat Yaylaci;Djafar Ait Kaci;Merve Terzi;Mehmet Emin Ozdemir;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • v.89 no.5
    • /
    • pp.539-547
    • /
    • 2024
  • This study examines crack behavior within orthopedic cement utilized in total hip replacements through the finite element method. Its main goal is to compute stress intensity factors (SIF) near the crack tip. The analysis encompasses two load types, static and dynamic, applied to a crack starting from the interface between the cement and bone. Specifically, it investigates SIFs under mixed mode conditions during three activities: normal walking, climbing upstairs, and downstairs. The results highlight that a crack originating from a micro-interface under substantial loading can cause cement damage, leading to prosthetic loosening. Stress intensity factors in modes I, II, and III are influenced by the crack tip's orientation and location in the bone cement, with a 90° orientation yielding notably higher values across all three modes.

Investigation of seismic performance of a premodern RC building typology after November 26, 2019 earthquake

  • Marsed Leti;Huseyin Bilgin
    • Structural Engineering and Mechanics
    • /
    • v.89 no.5
    • /
    • pp.491-505
    • /
    • 2024
  • This study evaluates the seismic performance of a premodern six story reinforced concrete building typology designed during the communism period of Albania and build throughout the country. During the November 26, 2019 Earthquake in Albania, the most affected reinforced concrete buildings were among the old templates, lacking shear walls and inadequate reinforcement details which suffer from concrete aging. The mathematical model of the selected building is done in the environments of ZeusNL software, developed especially for earthquake engineering applications. The capacity curve of the structure is gained using the conventional static nonlinear analysis. On the other hand, the demand estimation is utilized using one of the recent methods known as Incremental Dynamic Analysis with a set of 18 ground motion records. The limit states in both curves are defined based on the modern guidelines. For the pushover, immediate occupancy (IO), life safety (LS) and collapse prevention (CP) are plotted in the same graph with capacity curve. Furthermore, on each IDA derived, the IO, CP and global instability (GI) are determined. Moreover, the IDA fractiles are generated as suggested by the literature, 16%, 50% (median) and 84%. In addition, the comparative assessment of the IDA median with capacity curve shows good correlation points. Lastly, this study shows the approach of determination of LS in IDA fractiles for further vulnerability assessment based on the local seismic hazard map with 95 and 475 return period.

An Experimental Study on the Girder-Abutment Connection for the Steel-Concrete Composite Rigid-Frame Bridge Integrated with PS Bars (PS 강봉으로 일체화된 강합성 라멘교의 거더-교대 접합부의 거동에 관한 실험적 연구)

  • Lee, Sang-Yoon;Ahn, Young-Soo;Oh, Min-Ho;Chung, Jee-Seung;Yang, Sung-Don
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.453-463
    • /
    • 2012
  • Steel-concrete composite rigid-frame bridge is a type of integral bridge having advantages in bridge maintenance and structural efficiency from eliminating expansion joints and bridge supports, the main problems in bridge maintenance. The typical steel-concrete composite rigid-frame bridge has the girder-abutment connection where a part of its steel girder is embedded in abutment for integrity. However, the detail of typical girder-abutment connection is complex and increases the construction cost, especially when a part of steel girder is embedded. Recently, a new type of bridge was proposed to compensate for the disadvantages of complex details and cost increase. The compensation are expected to improve efficiency of construction by simplifying the construction detail of the girder-abutment connection. In this study, a static load test has been carried out to examine the behavior of the girder-abutment connection using real-scale specimens. The results of the test showed that the girder-abutment connection of proposed girder bridge has sufficient flexural capacity and rebars to control concrete crack should be placed on the top of abutment.

Implications of the effects of gravity load for earthquake resistant design of multistory building structurtes (고층건물의 내진설계에 미치는 중력하중의 영향)

  • 이동근;이석용
    • Computational Structural Engineering
    • /
    • v.6 no.3
    • /
    • pp.67-80
    • /
    • 1993
  • This paper presents the results of an analytical study to evaluate the inelastic seismic response characteristics of multistory building structures, the effects of gravity load on the seismic responses and its implications on the earthquake resistant design. Static analyses for incremental lateral force and nonlinear dynamic analyses for earthquake motions were performed to evaluate the seismic response of example multistory building structures. Most of considerations are placed on the distribution of inelastic responses over the height of the structure. When an earthquake occurs, bending moment demand is increased considerably from the top to the bottom of multistory structures, so that differences between bending moment demands and supplies are greater in lower floos of multistory structures. As a result, for building structures designed by the current earthquake resistant design procedure, inelastic deformations for earthquake ground motions do not distribute uniformly over the height of structures and those are induced mainly in bottom floors. In addition, gravity load considerded in design procedure tends to cause much larger damages in lower floors. From the point of view of seismic responses, gravity load affects the initial yield time of griders in earlier stage of strong earthquakes and results in different inelastic responses among the plastic hinges that form in the girders of a same floor. However, gravity load moments at beam ends are gradually reduced and finally fully relaxed after a structure experiences some inelastic excursions as a ground motion is getting stronger. Reduction of gravity load moment results in much increased structural damages in lower floors building structures. The implications of the effects of gravity load for seismic design of multistory building structures are to reduce the contributions of gravity load and to increased those of seismic load in determination of flexual strength for girders and columns.

  • PDF

Design Graphs for Asphalt Concrete Track with Wide Sleepers Using Performance Parameters (성능요소를 반영한 광폭 침목형 아스팔트콘크리트 궤도 설계그래프)

  • Lee, SeongHyeok;Lim, Yujin;Song, Geunwoo;Cho, Hojin
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.331-340
    • /
    • 2016
  • Wheel load, design velocity, traffic amount (MGT), stiffness and thickness of sub-layers of asphalt concrete track are selected as performance design parameters in this study. A pseudo-static wheel load computed considering the dynamic amplification factor (DAF) based on the design velocity of the KTX was applied to the top of asphalt concrete track for full three dimensional structural analysis using the ABAQUS program. Tensile strains at the bottom of the asphalt concrete layer and vertical strains at the top of the subgrade were computed from the structural FEA with different combinations of performance parameter values for one asphalt concrete track section. Utilizing the computed structural analysis results such as the tensile strains and the vertical strains, it was possible to develop design graphs to investigate proper track sections for different combination of the performance parameters including wheel load, design velocity, traffic amount(MGT), stiffness and thickness of asphalt concrete layers for any given design life. By analyzing the proposed design graphs for asphalt concrete track, it was possible to propose simple design tables that can be used by engineers for the effective and fast design of track.

Study of Failure Mode and Static Behavior of Lightweight FRP Truss Bridge Deck System (복합재료 트러스 교량시스템의 정적거동 및 파괴모드에 관한 해석적 연구)

  • Jung, Woo-Young;Lee, Hyung-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.511-520
    • /
    • 2007
  • There is a concern with worldwide deterioration of highway bridges, particularly reinforced concrete. The advantages of fibre reinforced plastic(FRP) composites over conventional materials motivate their use in highway bridges for replacement of structures. Recently, an FRP deck has been installed on a state highway, located in New York State, as an experimental project. In this paper, a systematic approach for analysis of this FRP deck bridge is presented. Multi-step linear numerical analyses have been performed using the finite element method to study the structural behavior and the possible failure mechanism of the FRP deck-superstructure system. Deck's self-weight and ply orientations at the interface between steel girders and FRP deck are considered in this study. From this research, the results of the numerical analyses were corroborated with field test results. Analytical results reveal several potential failure mechanism for the FRP deck and truss bridge system. The results presented in this study may be used to propose engineering design guideline for new and replacement FRP bridge deck structure.

Seismic Performance of Column-Footing Connection of Modular Pier using CFT (CFT를 이용한 모듈러 교각 기둥-기초 연결부의 내진성능)

  • Kim, Ji Young;Kim, Ki Doo;Ma, Hyang Wook;Chung, Chul-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.73-85
    • /
    • 2014
  • The CFT (Concrete Filled steel Tubes) column-footing connection is cast-in-place embedded type which provides simple construction procedure, low cost, and superior structural performance. In this study, CFT column-footing connection of modular pier is proposed and structural performance is evaluated by experimental tests. To evaluate structural performance of the CFT column-footing connection, a series of experimental tests were performed for the 4 specimens with different embedded depth. As a result of the quasi-static test, the specimen with 0.6D (0.6 times the outside diameter of steel tube) embedded depth showed relatively low ductility than other specimens with larger embedded depth due to cone failure of base concrete occurred during the lower loading step. On the contrary, cone failure of the base concrete was not observed in the specimens with larger embedded depth than 0.9D, but typical flexural failure in lower part of CFT column was observed. With the analyses of force-displacement curve, displacement ductility, and energy dissipation capacity, it is concluded that the rational range of embedded depth of the CFT column-footing connection is from 0.9D to 1.2D in view of good seismic performance.

Geodesic Shape Finding Algorithm for the Pattern Generation of Tension Membrane Structures (막구조물의 재단도를 위한 측지선 형상해석 알고리즘)

  • Lee, Kyung-Soo;Han, Sang-Eul
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.33-42
    • /
    • 2010
  • Patterning with a geodesic line is essential for economical or efficient usage of membrane materialsin fabric tension membrane structural engineering and analysis. The numerical algorithm to determine the geodesic line for membrane structures is generally classified into two. The first algorithm finds a non-linear shape using a fictitious geodesic element with an initial pre-stress, and the other algorithm is the geodesic line cutting or searching algorithm for arbitrarily curved 3D surface shapes. These two algorithms are still being used only for the three-node plane stress membrane element, and not for the four-node element. The lack of a numerical algorithm for geodesic lines with four-node membrane elements is the main reason for the infrequent use of the four-node membrane element in membrane structural engineering and design. In this paper, a modified numerical algorithm is proposed for the generation of a geodesic line that can be applied to three- or four-node elements at the same time. The explicit non-linear static Dynamic Relaxation Method (DRM) was applied to the non-linear geodesic shape-finding analysis by introducing the fictitiously tensioned 'strings' along the desired seams with the three- or four-node membrane element. The proposed algorithm was used for the numerical example for the non-linear geodesic shape-finding and patterning analysis to demonstrate the accuracy and efficiency, and thus, the potential, of the algorithm. The proposed geodesic shape-finding algorithm may improve the applicability of the four-node membrane element for membrane structural engineering and design analysis simultaneously in terms of the shape-finding analysis, the stress analysis, and the patterning analysis.