• Title/Summary/Keyword: Statement Analysis

Search Result 599, Processing Time 0.035 seconds

Detecting suspicious branch statements through recording and analyzing execution logs of apps using reflection (리플렉션이 사용된 앱의 실행 로그 기록 및 분석을 통한 의심스러운 분기문 탐지)

  • Sumin Lee;Minho Park;Jiman Hong
    • Smart Media Journal
    • /
    • v.12 no.5
    • /
    • pp.58-64
    • /
    • 2023
  • In Logic Bomb, the conditions of branch statements that trigger malicious behavior cannot be detected in advance, making Android malicious app analysis difficult. Various studies have been conducted to detect potentially suspicious branch statements that can be logic bombs and triggers, but suspicious branch statements cannot be properly detected in apps that contain information determined at runtime, such as reflection. In this paper, we propose a tool that can detect suspicious branch statements even when reflection is used in Android apps. It works through recording app execution logs and analyzing the recorded log). The proposed tool can check the relationship between the called method and the branch statement by recording and analyzing the user-defined methods, Java APIs called and method information called through reflection, and branch information in the log while the Android app is running. Experimental results show that suspicious branch statements can be detected even in apps where reflection is used.

Nutritional evaluation of new alternative types of dog foods including raw and cooked homemade-style diets

  • Boyeon Choi;San Kim;Goo Jang
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.63.1-63.9
    • /
    • 2023
  • Background: New alternative types of pet foods such as raw and cooked homemadestyle diets containing human food ingredients have been introduced due to a trend of pet humanization and diversification of consumer needs. Objectives: To evaluate nutritional adequacy of new alternative types of dog foods containing human food ingredients as maintenance diets for dogs. Methods: Eleven homemade-style foods for adult dogs were purchased from online channel in Korea and analyzed to evaluate nutritional adequacy for adult dogs. Nutrients analyzed included crude protein, amino acids, crude fat, fatty acids, and minerals. Results: Crude protein and amino acids in all products satisfied Association of American Feed Control Officials (AAFCO) requirements. Crude fat in one of 11 products did not meet AAFCO requirements. The most deficient minerals were selenium (10 of 11, 90.9%), copper (five of 11, 45.5%), zinc (five of 11, 45.5%), potassium (three of 11, 27.3%), calcium (three of 11, 27.3%), iron (two of 11, 18.2%), and magnesium (one of 11, 9.1%). Six products were not in the range of the recommended Ca:P ratio in AAFCO dog food maintenance nutrient profiles. Conclusions: This study performed nutritional evaluation of raw and cooked homemadestyle foods as maintenance diets for adult dogs. Some nutritional inadequacies were observed including some minerals, Ca:P ratio, and omega-6:omega-3 fatty acid ratio, although three products (26.2%) satisfied the AAFCO standard except selenium. Overall, the data suggest a need for accurate nutritional adequacy statement for consumers based on proper methods to validate the formula.

Case Study on Secondary Science Teachers' Classroom Teaching Evaluation (중등 과학 교사 수업 평가에 대한 사례 연구)

  • Jeon, Hwa-Young;Hong, Hun-Gi;Park, Eun-I;Kim, Hyun-Jung
    • Journal of The Korean Association For Science Education
    • /
    • v.29 no.1
    • /
    • pp.106-115
    • /
    • 2009
  • In this study, classroom instructions of teachers who participate in the science teachers' community were videotaped and analyzed to understand their teaching professionalism. Among the "Standards for teaching evaluation of science instruction" developed by Korea Education Curriculum and Assessment, 12 evaluation elements were selected and used for data analysis. First of all, the results indicate that most of the teachers show the highest teaching level in the interaction between student and teacher, and the lowest in the statement of teaching object as the teaching evaluation element. Second, from the viewpoint of the teaching level, all of the teachers at the superior level were veterans whose teaching careers have spanned longer than 15 years. It was found that they used various teaching materials in class and designed meaningful learning programs for their students. Compared with teachers at the superior level, beginning teachers used limited teaching materials due to their lack of experience. In addition, their instruction falls short of flexible management in teaching. The results show that they tend to teach in a somewhat rigid style that does not have sufficient positive interaction with students.

An analysis of elementary students' reasoning on the sum of triangle angles ('삼각형 세 각의 크기의 합'에 관한 초등학생의 추론 연구)

  • Kim, Ji Hyun
    • Education of Primary School Mathematics
    • /
    • v.27 no.2
    • /
    • pp.155-171
    • /
    • 2024
  • This study compared and analyzed students' reasoning processes and justification methods when introducing the concept of "the sum of angles in a triangle" in mathematics classes with a focus on both measurement and geometric aspects. To confirm this, the research was conducted in a 4th-grade class at H Elementary School in Suwon, Gyeonggi-do, South Korea. The conclusions drawn from this study are as follows. First, there is a significant difference when introducing "the sum of angles in a triangle" in mathematics classes from a measurement perspective compared to a geometric perspective. Second, justifying the statement "the sum of angles in a triangle is 180°" is more effective when explained through a measurement approach, such as "adding the sizes of the three angles gives 180°," rather than a geometric approach, such as "the sum of the angles forms a straight angle." Since elementary students understand mathematical knowledge through manipulative activities, the level of activity is connected to the quality of mathematics learning. Research on this reasoning process will serve as foundational material for approaching the concept of "the sum of angles in a triangle" within the "Geometry and Measurement" domain of the Revised 2022 curriculum.

Procedural outcomes of laparoscopic caudate lobe resection: A systematic review and meta-analysis

  • Shahab Hajibandeh;Ahmed Kotb;Louis Evans;Emily Sams;Andrew Naguib;Shahin Hajibandeh;Thomas Satyadas
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.6-19
    • /
    • 2023
  • A systematic review was conducted in compliance with PRISMA statement standards to identify all studies reporting outcomes of laparoscopic resection of benign or malignant lesions located in caudate lobe of liver. Pooled outcome data were calculated using random-effects models. A total of 196 patients from 12 studies were included. Mean operative time, volume of intraoperative blood loss, and length of hospital stay were 225 minutes (95% confidence interval [CI], 181-269 minutes), 134 mL (95% CI, 85-184 mL), and 7 days (95% CI, 5-9 days), respectively. The pooled risk of need for intraoperative transfusion was 2% (95% CI, 0%-5%). It was 3% (95% CI, 1%-6%) for conversion to open surgery, 6% (95% CI, 0%-19%) for need for intra-abdominal drain, 1% (95% CI, 0%-3%) for postoperative mortality, 2% (95% CI, 0%-4%) for biliary leakage, 2% (95% CI, 0%-4%) for intra-abdominal abscess, 1% (95% CI, 0%-4%) for biliary stenosis, 1% (95% CI, 0%-3%) for postoperative bleeding, 1% (95% CI, 0%-4%) for pancreatic fistula, 2% (95% CI, 1%-5%) for pulmonary complications, 1% (95% CI, 0%-4%) for paralytic ileus, and 1% (95% CI, 0%-4%) for need for reoperation. Although the available evidence is limited, the findings of the current study might be utilized for hypothesis synthesis in future studies. They can be used to inform surgeons and patients about estimated risks of perioperative complications until a higher level of evidence is available.

Comparing Misconceptions of Scientifically-Gifted and General Elementary Students in Physics Classes (초등학교 과학 영재와 일반 학생의 물리 오개념 비교)

  • Kwon, Sung-Gi;Kim, Ji-Eun
    • Journal of Korean Elementary Science Education
    • /
    • v.25 no.spc5
    • /
    • pp.476-484
    • /
    • 2007
  • The purpose of this study is to examine the misconception profiles of the scientifically-gifted and non-gifted children in terms of basic physics concepts and to compare them in terms of the types of differences in misconception as well as in their understanding of the concepts themselves. The subjects of this study were 75 scientifically-gifted children attending the Educational Center of Gifted Children in DNUE and 148 non-gifted children in elementary schools in Daegu city. For the purposes of this study, the basic concepts of physics (heat, electromagnetism, force, and light) which should be learned in an elementary school were selected with a review of related previous research and with an analysis of the 7th science curriculum. Next, a questionnaire was made which was made up of 20 multiple choice statement based items. Analysis of the results of the statement sections in the test, it was hoped, would reveal the difference between the scientifically-gifted and the non-gifted children's understanding, while the responses in the multiple choice items would suggest the differences between the two groups in terms of the misconceptions regarding physics concepts. The results of this study are as follows: First, although both the gifted and non-gifted children showed a low level of understanding of the concepts of heat, electromagnetism, force, and light, the gifted children' level of understanding of those physics concepts was proved to be significantly higher than the non-gifted, so it seems that the scientifically-gifted children have fundamentally understood the concepts in physics and have a higher level of understanding of them. Additionally, both the scientifically-gifted and non-gifted children' level of understanding of all the concepts was lower in the order of electromagnetism, heat, force, and light. This shows that both the scientifically-gifted and the non-gifted children have no difference in the level of understanding of any specific physics concept, but have similar levels of difficulty in every concept. Second, both the scientifically-gifted and non-gifted children showed similar types of misconceptions. However, the scientifically-gifted children had fewer misconceptions than the non-gifted. We suggest that scientifically-gifted children's misconceptions were not fixed yet, so there remained a possibility of them being corrected easily with appropriate instruction.

  • PDF

A Strategic Quality Initiative and Its Opportunities to Improve Healthcare Environment (진료환경개선을 위한 우선적 전략과제 설정 및 그 적용)

  • Tark, Kwan-Chul;Park, Hyun-Ju;Park, Chang-Il;Kang, Jin-Kyung
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.324-334
    • /
    • 1998
  • Background : Strategic planning is an organizationwide or systemwide, ongoing look into the future usually of 2~3 years, based on objective analysis of the current environment and trends, but it can incorporate both short-term and long-term goals. The strategic planning process includes external analysis, internal analysis, issue analysis, development of mission, vision and values, and lastly development of organizational goals and objectives. As a part of the strategic quality planning process, certain service lines, important organizationwide functions, or key processes supporting these functions can be prioritized to expedite and roll out certain strategic goals. This is called strategic quality initiatives. Methods : We organized a quality improvement team, a subgroup of 21st century vision planning corps of our medical center, and pursued QI activities for improvement of healthcare environment, particularly in the admission setting. We developed a strategic quality initiative based on the results of patient satisfaction surveys, and carried out functions of self-directed work team. Results : The strategic goal was to be the benchmark for peer group hospitals in Korea for providing cost-effective best-practice. The QI team included 3 medical doctors, 1 nurse, 1 social worker, and 1 QI consultant as well as many operational members to support services and quality initiatives met every Tuesday for 18 weeks. Outcome objectives were to improve patient satisfaction score. The issues included in the objectives were comfort, temperature, noise, cleanliness of the admission wards, quality and education of patient meals, matters regarding the admission process, and an appurtenant facility such as restaurant or convenience store. Every issue was discussed and recommendations, conclusions and opportunities were implemented. Conclusions : By developing a strategic quality initiative as a part of the strategic quality planning process, and pursuing a self-directed work team, certain sen/ice lines, important organizationwide functions, or key processes supporting these functions can be improved effectively within a short period. Strategic quality initiatives serve to support, or roll out, certain strategic goals that are relevant to performance improvement and development of specific measurable outcome objectives, and associated performance measure for each initiative. Each strategic quality initiative should include a statement of intent outcome objectives, and performance measures. We will come back with follow up of the strategic quality initiative, for improvement of healthcare environment, and results of patient satisfaction re-survey.

  • PDF

EFFECT OF CASTING PROCEDURE ON SCREW LOOSENING OF UCLA ABUTMENT IN TWO IMPLANT-ABUTMENT CONNECTION SYSTEMS

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.246-254
    • /
    • 2008
  • STATEMENT OF PROBLEM: The cast abutment has advantages of overcoming angulation problem and esthetic problem. However, when a gold-machined UCLA abutment undergoes casting, the abutment surfaces in contact with the implant may change. PURPOSE: The purpose of this study was to compare the detorque values of prefabricated machined abutments with gold-premachined cast-on UCLA abutments before and after casting in two types of internal implant-abutment connection systems: (1) internal hexagonal joint, (2) internal octagonal joint. Furthermore, the detorque values of two implant-abutment connection systems were compared. MATERIALS AND METHODS: Twenty internal hexagonal implants with an 11-degree taper and twenty internal octagonal implants with an 8-degree taper were acquired. Ten prefabricated titanium abutments and ten gold-premachined UCLA abutments were used for each systems. Each abutment was torqued to 30 N㎝ according to the manufacturer's instructions and detorque value was recorded. The detorque values were measured once more, after casting with gold alloy for UCLA abutment, and preparation for titanium abutments. Group means were calculated and compared using independent t-test and paired t-test (${\alpha}$=0.05). RESULTS: The results were as follows: 1. The detorque values between titanium abutments and UCLA-type abutments showed significant differences in internal octagonal implants (P<0.05), not in internal hexagonal implants (P>0.05). 2. In comparison of internal hexagonal and octagonal implants, the detorque values of titanium abutments had significant differences between two connection systems on the initial analysis (P<0.05), not on the second analysis (P>0.05) and the detorque values of UCLA-type abutments were not significantly different between two connection systems (P>0.05). 3. The detorque values of titanium abutments and UCLA-type abutments decreased significantly on the second analysis than the initial analysis in internal hexagonal implants (P<0.05), not in internal octagonal implants (P>0.05). CONCLUSION: Casting procedures of UCLA-type abutments had no significant effect on screw loosening in internal implant-abutment connection systems, and UCLA-type abutments showed higher detorque values than titanium abutments in internal octagonal implants.

The effect of low temperature aging on the mechanical property & phase stability of Y-TZP ceramics

  • Kim, Hyung-Tae;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.113-117
    • /
    • 2009
  • STATEMENT OF PROBLEM. Recently Yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) has been introduced due to superior flexural strength and fracture toughness compared to other dental ceramic systems. Although zirconia has outstanding mechanical properties, the phenomenon of decrease in the life-time of zirconia resulted from degradation in flexural strength after low temperature aging has been reported. PURPOSE. The objective of this study was to investigate degradation of flexural strength of Y-TZP ceramics after various low temperature aging treatments and to evaluate the phase stability and micro-structural change after aging by using X-ray diffraction analysis and a scanning electron microscope (SEM). MATERIAL AND METHODS. Y-TZP blocks of Vita In-Ceram YZ (Vita Zahnfabrik, Bad $S\ddot{a}ckingen$, Germany) were prepared in 40 mm (length) $\times$ 4 mm (width) $\times$ 3 mm (height) samples. Specimens were artificially aged in distilled water by heat-treatment at a temperature of 75, 100, 125, 150, 175, 200, and $225^{\circ}C$ for 10 hours, in order to induce the phase transformation at the surface. To measure the mechanical property, the specimens were subjected to a four-point bending test using a universal testing machine (Instron model 3365; Instron, Canton, Mass, USA). In addition, X-ray diffraction analysis (DMAX 2500; Rigaku, Tokyo, Japan) and SEM (Hitachi s4700; Jeol Ltd, Tokyo, Japan) were performed to estimate the phase transformation. The statistical analysis was done using SAS 9.1.3 (SAS institute, USA). The flexural strength data of the experimental groups were analyzed by one-way analysis of variance and to detect statistically significant differences ($\alpha$= .05). RESULTS. The mean flexural strength of sintered Vita In-Ceram YZ without autoclaving was 798 MPa. When applied aging temperature at below $125^{\circ}C$ for 10 hours, the flexural strength of Vita In-Ceram YZ increased up to 1,161 MPa. However, at above $150^{\circ}C$, the flexural strength started to decrease. Although low temperature aging caused the tetragonal-to-monoclinic phase transformation related to temperature, the minimum flexural strength was above 700 MPa. CONCLUSION. The monoclinic phase started to appear after aging treatment above $100^{\circ}C$. With the higher aging temperature, the fraction of monoclinic phase increased. The ratio of monoclinic/tetragonal + monoclinic phase reached a plateau value, circa 75% above $175^{\circ}C$. The point of monoclinic concentration at which the flexural strength begins to decrease was between 12% and 54%.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.