• 제목/요약/키워드: State delay controller

검색결과 190건 처리시간 0.028초

상태지연을 갖는 2차 시스템의 LQ-PID 제어기 동조 (LQ-PID Controller Tuning For Second Order Systems with State delay)

  • 권호제;서병설
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2513-2516
    • /
    • 2003
  • This paper presents an optimal robust LQ-PID roller design method for the second-order ems with state delay to satisfy the design ification in time domain. The Sensitivity bach concept is utilized for its optimization.

  • PDF

Robust Reliable H$\infty$ a Control of Continuous/Discrete Uncertain Time Delay Systems using LMI

  • Kim, Jong-Hae;Park, Hong-Bae
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제1권2호
    • /
    • pp.121-127
    • /
    • 1999
  • In this paper, we present robust reliable H$\infty$ controller design methods of continuous and discrete uncertain time delay systems using LMI (linear matrix inequality) technique, respectively. Also the existence conditions of state feedback control are proposed . Using some changes of variables and Schur complements, the obtained sufficient conditions are transformed into an LMI form. The closed loop system by the obtained controller is quadratically stable with H$\infty$ norm bound for all admissible uncertainties, time delay, and all actuator failures occurred within the prespecified set. We show the validity of the proposed method through numerical example.

  • PDF

Robust stabilization of time-delay systems with nonlinear uncertainties

  • Park, Juhyun;Won, Sangchul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1197-1200
    • /
    • 1996
  • This paper is concerned with the design of robust state feedback controller for a class of linear time-delay systems with norm-bounded nonlinear uncertainties. Under the proposed delay-independent criterion, asymptotic stability for the system is investigated using the conventional Lyapunov method. Moreover, the robust controller can be obtained by solving the linear matrix inequality which is equivalent to the suggested conditions.

  • PDF

작은지연을 갖는 플랜트에 대한 LQ-PID 제어기 설계 (LQ-PID controller design for the Plant with small delay)

  • 박재규;서병설
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.327-330
    • /
    • 2003
  • This paper presents an optimal robust LQ-PID controller design method for the second-order system with both small state delay and small input delay to satisfy the design specifications in time domain. The modified sensitivity approach method is considered for its optimization.

  • PDF

CAN을 이용한 발전계통의 제어 및 모니터링 기법 연구 (A Study on the Power System Control and Monitoring Technique Using CAN)

  • 정준홍;최수영;박기헌
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.268-276
    • /
    • 2003
  • In this paper, we present a new control and monitoring technique for a power system using CAN(Controller Area Network). Feedback control systems having co'ntrol loops closed through a network(i.e. Ethernet, ControlNet, CAN) are called NCSs(Networked Control Systems). The major problem of NCSs is the variation of stability property according to time delay including network-induced delay and computation delay in nodes. We present a new stability analysis method of NCSs with time delay exploiting a state-space model of LTI(Linear Time Invariant) interconnected systems. The proposed method can determine a proper sampling period of NCSs that preserves stability performance even in NCSs with a dynamic controller. We design CAN nodes which can transmit control and monitoring data through CAN bus and apply these to NCSs for a power system. The results of the experiment validate effectiveness of our control and monitoring technique for a power system.

PID 제어기를 이용한 확장 적분 제어 (Extended Integral Control with the PID Controller)

  • 문영현;정기영;류헌수;송경빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1063-1066
    • /
    • 1999
  • This paper presents an extended integral control with the PID controller by introducing the delay and decaying factors. The convolution integral control scheme is developed by substituting proportional convolution integral controls for the proportional-integral control. So far, the integral part of the PI controller produces a signal that is proportional to the time integral of the input of the controller. The steady-state operation points are affected forever by the errors in the past due to the input signal containing the information of the errors in the past. These phenomina may cause some disturbances for other control purposes related to the given PI control. Introduction of forgetting factors of the error in the past can resolve the disturbance problems. Various forgetting factors are developed using the delay, the decaying factors, and the combination of the delay and the decaying factors. The proposed various extended integral control schemes can be applicable to corresponding PI control designs in which the error in the past may badly affect to the current steady-state operation points and may cause some disturbances for other control purposes.

  • PDF

Compensation of Networked Control Systems Using LMI-based Delay-dependent H_infinity Optimization Method

  • Yoo, Ho-Jun;Ryu, Hee-Seob;Kwon, Oh-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.54.6-54
    • /
    • 2002
  • 1. Introduction 2. The Netwoked Control System Description 2.1 A close-loop system with the network induced delay 2.2 Discretization and State Augmentation of NCS 3. Delay-dependent H_infinity Controller Design for NCS 4. Numerical Example 5. Conclusion

  • PDF

시간 지연 제어를 이용한 영전압 스위칭 PWM 하프 브릿지 컨버터의 제어 성능 개선 (Performance Improvement of Zero Voltage Switching PWM Half Bridge DC/DC Converter Using Time Delay Control Method)

  • 강정일;정영석;이준영;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.85-89
    • /
    • 1998
  • A switching power stage is a very nonlinear system because it has two or more operation modes in one switching cycle. To model a switching power stage, the state space averaging method has been developed. Though it allows a unified treatment of a large variety of switching power stages, the model it yields is always very nonlinear. So, it is required to linearize the averaged model. But it is well known that a controller for a nonlinear plant designed by the linearization frequently fails in showing satisfactory control performance. Hence it is very natural to try to design a nonlinear controller for a switching power stage. In design of a switching power system, nonlinear control approaches such as adaptive control and fuzzy control have been widely studied so far. In this research, a recently developed control method, time delay control is briefly studied and a design example for a ZVS PWM half bridge converter is given. The performance of the time delay controller is compared to its conventional counterpart, PI controller by computer simulations.

  • PDF

Analysis of Proportional Control for Grid Connected Inverter With LCL Filter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.247-249
    • /
    • 2008
  • There are many types of grid-connected inverter controllers; Synchronous Reference Frame (SRF)-based controller is the most popular methods. SRF-based controller is capable for reducing both of zero-steady state error and phase delay. However, SRF-based controller has a complex algorithm to apply in real application such as digital processor. Resonant controller is also reduced zero-steady state error, but its transfer function has a high order. In this paper, a simple proportional control is applied for grid connected inverter with LCL filter. LCL filter is a third order system. Applying a simple proportional controller is not increased the order of closed loop transfer function. By this technique, the single phase model is easily obtained. To reduce steady state error, proportional gain is set as high as possible, but it may produce instability. To compromise between a minimum steady state error and stability, the single phase model is evaluate through Root Locus and Bode diagram. PSIM simulation is used to verify the analysis.

  • PDF

Digital Control of a Single-Phase UPS Inverter for Robust AC-Voltage Tracking

  • Woo Young-Tae;Kim Young-Chol
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권4호
    • /
    • pp.620-630
    • /
    • 2005
  • This paper presents a digital controller for a single phase UPS inverter under two main considerations: (i) the overall system shall keep very low AC-voltage tracking error as well as no phase delay over different load conditions, and (ii) the digital controller shall be employed at a fixed sampling time. We propose that the former can be achieved by the proposed controller using the error-state approach and the latter can be dealt with by the socalled characteristics ration assignment.