• Title/Summary/Keyword: State delay controller

Search Result 190, Processing Time 0.024 seconds

DRA: Duplication Resolver Algorithm for Power Conservation Utilizing Software Defined Network (SDN)

  • Masoud, Mohammad;Jaradat, Yousef;Jannoud, Ismael;Huang, Hong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.7
    • /
    • pp.3351-3369
    • /
    • 2017
  • In recent years, datacenters, network devices and computers have proliferated. The power consumed by information and communication technology (ICT) devices has inflated in an extraordinary manner. Green communication has emerged as a new approach to reduce and optimize power consumption in ICT sector. Many methods and protocols have been proposed and implemented to achieve green communication. Nevertheless, the increase of power consumption remains a problem. In this work, we attempt to reduce and optimize power consumption of network devices in datacenters environment utilizing software defined network (SDN) paradigm. To gain more insight of the power consumption requirements of network switches, a power measurement system is constructed to measure power consumption levels of network devices. Subsequently, we propose a duplication resolver algorithm (DRA) to power off/on switches reactively. DRA algorithm reduces the required time by switches to construct their flow tables after rebooting. To this end, DRA-based external circuit has been constructed utilizing Ethernet module and an Arduino kit to control power supplies of network devices. To facilitate our work, a testbed has been constructed utilizing Ryu SDN controller, HP2920-24G switches and Arduino kits. Our results show that DRA algorithm can reduce both the power usage and start-up time delay of network switches after failures.

Digital Modeling of a Time delayed Continuous-Time System (시간 지연 연속 시간 시스템의 디지털 모델링)

  • Park, Jong-Jin;Choi, Gyoo-Seok;Park, In-Ku;Kang, Jeong-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.211-216
    • /
    • 2012
  • Control Theory for continuous-time system has been well developed. Due to the development of computer technology, digital control scheme are employed in many areas. When delays are in control systems, it is hard to control the system efficiently. Delays by controller-to-actuator and sensor-to-controller deteriorate control performance and could possibly destabilize the overall system. In this paper, a new approximated discretization method and digital design for control systems with multiple state, input and output delays and a generalized bilinear transformation method with a tunable parameter are also provided, which can re-transform the integer time-delayed discrete-time model to its continuous-time model. Illustrative example is given to demonstrate the effectiveness of the developed method.

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

Identification of First-order Plus Dead Time Model from Step Response Using HS Algorithm (HS 알고리즘을 이용한 계단응답으로부터 FOPDT 모델 인식)

  • Lee, Tae-Bong
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.636-642
    • /
    • 2015
  • This paper presents an application of heuristic harmony search (HS) optimization algorithm for the identification of linear continuous time-delay system from step response. Identification model is first-order plus dead time (FOPDT), which describes a linear monotonic process quite well in most chemical processes and HAVC process and is often sufficient for PID controller tuning. This recently developed HS algorithm is conceptualized using the musical process of searching for a perfect state of harmony. It uses a stochastic random search instead of a gradient search so that derivative information is unnecessary. The effectiveness of the identification method has been demonstrated through a number of simulation examples.

Fast-Transient Repetitive Control Strategy for a Three-phase LCL Filter-based Shunt Active Power Filter

  • Zeng, Zheng;Yang, Jia-Qiang;Chen, Shi-Lan;Huang, Jin
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.392-401
    • /
    • 2014
  • A fast-transient repetitive control strategy for a three-phase shunt active power filter is presented in this study to improve dynamic performance without sacrificing steady-state accuracy. The proposed approach requires one-sixth of the fundamental period required by conventional repetitive control methods as the repetitive control time delay in the synchronous reference frames. Therefore, the proposed method allows the system to achieve a fast dynamic response, and the program occupies minimal storage space. A proportional-integral regulator is also added to the current control loop to eliminate arbitrary-order harmonics and ensure system stability under severe harmonic distortion conditions. The design process of the corrector in the fast-transient repetitive controller is also presented in detail. The LCL filter resonance problem is avoided by the appropriately designed corrector, which increases the margin of system stability and maintains the original compensation current tracking accuracy. Finally, experimental results are presented to verify the feasibility of the proposed strategy.

A Moving Window Principal Components Analysis Based Anomaly Detection and Mitigation Approach in SDN Network

  • Wang, Mingxin;Zhou, Huachun;Chen, Jia
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.8
    • /
    • pp.3946-3965
    • /
    • 2018
  • Network anomaly detection in Software Defined Networking, especially the detection of DDoS attack, has been given great attention in recent years. It is convenient to build the Traffic Matrix from a global view in SDN. However, the monitoring and management of high-volume feature-rich traffic in large networks brings significant challenges. In this paper, we propose a moving window Principal Components Analysis based anomaly detection and mitigation approach to map data onto a low-dimensional subspace and keep monitoring the network state in real-time. Once the anomaly is detected, the controller will install the defense flow table rules onto the corresponding data plane switches to mitigate the attack. Furthermore, we evaluate our approach with experiments. The Receiver Operating Characteristic curves show that our approach performs well in both detection probability and false alarm probability compared with the entropy-based approach. In addition, the mitigation effect is impressive that our approach can prevent most of the attacking traffic. At last, we evaluate the overhead of the system, including the detection delay and utilization of CPU, which is not excessive. Our anomaly detection approach is lightweight and effective.

A Rejection of Harmonic Ripples for d-q Transformation (d-q 변환에서의 고조파 맥동 제거)

  • Choi, Nam-Yerl;Lee, Chi-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.83-87
    • /
    • 2015
  • This paper presents a simple notch filter, which is so suitable for three-phase unbalanced and distorted power line. In the d-q synchronous transformation, three-phase unbalanced and distorted voltages generate lots of ripple voltages on d-q axes. The ripples make disturbances on controllers such as PLL of phase tracking. Unbalanced state makes ripple of double the frequency of power line. Odd harmonics 5th and 7th on the line make even 4th and 6th ripples on d-q axes due to the rotating reference frame, respectively. Cascaded two comb filters, delay lines 1/4T and 1/8T, are adopted for the ripple rejection. The filter rejects harmonics 2nd, 4th, 6th, 10th and so on. They are very effective to remove the ripples of both unbalance and distortion. The filter, implemented by two FIFOs on an experimental system, is adopted on a PLL controller of power line phase tracking. Through the simulation and experimental results, performance of the proposed comb filter has been validated.

Design of Dual Fuzzy Logic Controller using $e-{\Delta}e$ Phase Plane for Hydraulic Servo Motor (유압 서보 모터를 위한 $e-{\Delta}e$ 위상평면을 이용한 이중 퍼지 로직 제어기 설계)

  • Shin, Wee-Jae;Moon, Jeong-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.222-226
    • /
    • 2007
  • In this paper we composed the dual fuzzy rules using each region of specific points and $e-{\Delta}e$ phase plane In order to make dual fuzzy rule base. We composed the fuzzy control rules which can decrease rise time, delay time, maximum overshoot than basic fuzzy control rules. proposed method is alternately use at specific points of $e-{\Delta}e$ phase plane with two fuzzy control rules that is one control rule occruing the steady state error in transient region and another fuzzy control rule use to decrease the steady state error and rapidly converge at the convergence region. Also, two fuzzy control rules in the $e-{\Delta}e$ phase plane decide the change time according to response characteristics of plants. In order to confirm thef proposed algorithm. As the results of experiments through the hydraulic servo motor control system with a DSP processor, We verified that proposed dual fuzzy control rules get the good response compare with the basic fuzzy control rule.

  • PDF

Development of a self-leveling system for the bucket of an agricultural front-end loader using an electro hydraulic proportional valve and a tilt sensor (전자유압 비례밸브와 경사센서를 이용한 농용 프론트 로더 버켓 능동수평유지 시스템 개발)

  • Lee, Chang Joo;Ha, Jong Woo;Choi, Deok Su;Kim, Hak Jin
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.60-70
    • /
    • 2015
  • A front-end loader (FEL) mounted on an agricultural tractor is one of the most commonly used implements for farm work. However, when the tractor carries material using the bucket attached to the FEL on a sloping ground, the materials can spill or roll back over the operator due to the tilted body, thereby requiring the bucket surface to remain level at a constant value regardless of varying slopes. In this study, an active system for controlling the angle of the FEL bucket on a tractor based on the real-time measurement of ground slopes was developed to enable the bucket to constantly remain level. A FEL simulator operated based on an electro hydraulic proportional valve (EHPV) was constructed in the laboratory to develop a proportional-integral-derivative (PID) controller forming a virtual electronic control unit (ECU) on the computer, which could automatically adjust the bucket angles depending on varying input angles while sending SAE-J1939 associated messages via CAN BUS to the EHPV. The different parameter values for the PID controller due to the gravity effect of the bucket were determined using a manual PID tuning method while assuming that the tractor travels on either an ascending slope or a descending slope. The developed PID control-based self-leveling system showed a mean of steady-state errors of within $1^{\circ}$ and a mean of delayed times of ~ 0.8s when the step input of $+20^{\circ}$ was given, implying that the developed system and control algorithm would be effective in maintaining the bucket angle at a certain value. Future studies include the improvement of the control algorithm to reduce such a time delay as well as the application of the developed algorithm to the FEL mounted on a tractor tested at a testing ground.

A Study on Providing Real-Time Route Guidance Information by Variable Massage Signs with Driver Behavior (운전자 행태를 고려한 VMS의 실시간 경로안내 정보제공에 관한 연구)

  • Lee, Chang-U;Jeong, Jin-Hyeok
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.7 s.93
    • /
    • pp.65-79
    • /
    • 2006
  • The ATIS(Advance Traveler Information System), as one part of ITS, is a system aiming to disperse traffic volume on transportation networks by providing traffic information to transportation users on pre-trip and en-route trips. One of tools in ATIS is usage of VMS(Variable Message Signs). It provides to the drivers with direct information about state of processing direction. which is considered as the most effective method in ATIS. The purposes of providing VMS information are classified two categories. One is to provide simple information to drivers for their convenience. The other is to manage traffic demand to improve transportation network performance. However, for more effective and reliable VMS information, several strategies should be taken into account. The main VMS management strategy is "Traffic Diversion Strategy for minimum delay" when traffic congestion or incident are occurred. For effective operation. firstly. reasonable diversion traffic volume is determined by network traffic condition Secondly, it is necessary to make providing information strategy which reflects driver response behavior for controling diversion traffic volume. This paper focuses on the providing real-time route guidance information by VMS when congestion is occurred by the incidents. This sturdy estimates time-dependent system optimal diversion rate that inflects travel time and queue lengths using traffic flow simulation model on base Cellular Automata. In addition, route choice behavior models are developed using binary logit model for traffic information variable by traffic system controller. Finally, this study provides time-dependent VMS massage contents and degree of providing information in order to optimize the traffic flow.