전력계통 안정화를 위한 전압보상설비 운용 방안 (Operation method of Voltage Compensation Devices for power system stability)

  • 안창한;백영식
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.523-528
    • /
    • 2015
  • A new algorithm for a coordinative control method is proposed with respect to voltage control and system stabilization of local substations. This is accomplished using control cooperation between a static synchronous compensator (STATCOM) and the existing voltage compensation equipment in the steady state and emergency state of a power system. A real-time system analysis was developed by combining a system analysis program with InTouch, which has primarily been used in factory automation for verification. PSS/E was used for the load flow calculation software, Python for language, Intouch as an HMI program, and MS SQL for the database. To test this system, the system in the vicinity of the Migeum and the Migeum substations was modeled and simulated.

BESS 모델링 및 전기철도 급전계통에의 전압보상 적용 (BESS Modeling and Application to Voltage Compensation of Electric Railway System)

  • 유형준;손호익;김학만
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.417-423
    • /
    • 2013
  • The load of electric railroad can generate voltage fluctuation in the electric railway system because of high speed of the electric railroad and frequent movement and stop. This voltage fluctuation of electric railway system can cause not only voltage imbalance but also harmonic in the utility grid. Therefore the electric railroad system is in need of the reactive power compensation, such as static synchronous compensator (STATCOM) and static var compensator (SVC). Especially, the battery energy storage system (BESS) can control the real and reactive power at the same time. In this paper, the electric railway system using BESS has been modeled to show its voltage compensation effect using Matlab/Simulink.

퍼지제어기를 적용한 고속철도 급전 계통의 전압 변동 보상기법 (Voltage fluctuation compensation method for power supply system of high-speed rail using Fuzzy controller)

  • 김종규;양현석;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.491-492
    • /
    • 2013
  • 본 연구는 STATCOM을 이용하여 고속철도 급전 계통의 전압 변화를 보상하는 기법에 관한 것이다. 기존의 PI 제어기를 이용한 제어기법를 대신하여 본 연구에서는 퍼지제어기(FLC) 적용을 제안하며, 퍼지제어기와 PI제어기의 제어결과를 비교한다. 퍼지제어기를 통해 내부 파라미터 변동이나 외부의 환경 변화 등 계통의 변화시에 정상상태 편차, 정상상태 도달 시간 등을 최소화 시킬 수 있음을 보인다.

  • PDF

전력품질향상기기의 성능평가기술 - 소특집을 내면서 -

  • 추진부
    • 전기의세계
    • /
    • 제53권7호
    • /
    • pp.18-18
    • /
    • 2004
  • 수용가측의 전력품질에 대한 관심이 나날이 높아지고 있는 가운데 공장자동화, 및 컴퓨터의 보급확산으로 배전계통에 비선형 부하와 같은 악성부하들이 증가되고 있으며, 다른 한편으로는 공정제어기 및 인버터, 마이크로 프로세서와 같은 전력품질에 매우 민감한 부하기기들이 불특정 다수 분산적으로 도입ㆍ활용되고 있다. 이에 따라서 최근 전 세계적으로 전력품질에 의한 경제적 피해 사례가 보고되고 있어, 세계 선진국의 전력관련 산업체 및 연구소를 중심으로 한 전력품질 보상기기 개발에 대한 연구가 활발히 진행되고 있다. 이들에 대한 대표적인 기기들로서는 병렬형 전력품질 보상기기인 STATCOM(Static Compensator)과 직렬형 전력품질 보상기기인 DVR(Dynamic Voltage Restorer), 고속 전력 절체 스위치인 SSTS(Solid State Transfer Switch) 등을 열거할 수 있다. (중략)

  • PDF

다계 H-브리지 모듈로 구성된 UPFC(Unified Power flow Compensator)의 실험적 동작분석 (Experimental Operation Analysis of Unified Power Flow Controller with Cascaded H-Bridge Modules)

  • 백승택;한병문;추진부;장병훈;윤종수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.422-430
    • /
    • 2005
  • This paper describes experimental analysis of UPFC, which is composed of cascaded H-bridge modules and single-phase multi-winding transformers for isolation. The operational characteristic was analyzed through experimental works with a scaled model, and simulation results with PSCAD/EMTDC. The UPFC proposed in this paper can be directly connected to the transmission line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual WFC system applicable for the transmission system.

대규모 전려계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구 (FACTS Site Selections in Large Power Systems using Subtransmission System Reduction)

  • 장병훈;추진부;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1429-1433
    • /
    • 1999
  • This paper proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive power has been used to determine the location of shunt type FACTS device, but there is a difficulty to finding a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

시뮬레이션과 축소모형에 의한 UPFC의 성능해석 (Performance Analysis of UPFC by Simulation & Scaled Hardware Model)

  • 박지용;백승택;김희종;한병문;한학근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.579-586
    • /
    • 1999
  • This paper describes a simulation model and a scaled hardware model to analyze the dynamic performance of Unified Power Flow Controller, which can flexibly adjust the active power flow through the ac transmission line. The design of control system for UPFC was developed using vector control method. The results of simulation and scaled hardware test show that the developed control system works accurately. Both models would be very effective for analyzing the dynamic performance of the Unified Power Flow Controller.

  • PDF

FACTS 보상 송전선의 동적 해석을 통한 송전선 보호 방안 개선 (Improvement of Line Protection Methods by Dynamic Analysis on a FACTS-compensated transmission line)

  • 임정욱
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권12호
    • /
    • pp.573-579
    • /
    • 2005
  • Dynamic analysis of a transmission line which is compensated by a FACTS device such as STATCOM, SSSC and UPFC is carried out in this paper and the impacts on conventional line protection methods such as the DCPM (Differential Current Protection Method) and the DPM (Distance Protection Method) are reviewed. A refined DCRM is proposed to detect faults properly regardless of the FACTS operation. The proposed method is applied to a FACTS-compensated line with a variety of faults and is verified by simulation results. An adaptive DPM on a FACTS-compensated line was proposed previously in the literature. In order to emphasize the necessity of the modified DPM, the conventional DPM is applied to a FACTS-compensated system. Significant factors such as fault types, fault locations, and fault resistances as well as FACTS device types are considered for relaying setting.

배전용 일체형 에너지저장장치(ESS) 개발 (Development of All-In-One Type Energy Storage System(ESS) for Distribution Network)

  • 박민준;서정원;황광규;박주현;장재훈;김희중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.302-303
    • /
    • 2017
  • 본 논문에는 250KW급 에너지저장장치(ESS)를 이용한 일체형 배전용 계통연계 전력변환 장치를 제안한다. ESS는 전력 불안정에 따른 전력 손실을 줄이고 여름과 겨울, 낮과 심야시간의 전력수요 차이로 인한 전력수습의 불안정을 조절할 수 있는 최적의 수단이다. 제안된 배전용 일체형 ESS란 수용가 및 분산형 전원이 연계된 배전선로에 연결되어 조화롭고 안정적으로 운전될 수 있는 전력변환 장치이다. 충전된 전력을 효율적으로 계통으로 보내기 위하여 배전선로 전압제어기술(Statcom) 개발과 분산형 전원의 유 무효 전력제어, 역률 보상기(PF) 등의 기능을 적용하여 시뮬레이션, 프로토 타입 및 현장 시험을 이용하여 성능을 검증하였다.

  • PDF

80MVA UPFC 운전 결과 분석 (The Study of 80VMA UPFC operation)

  • 김수열;윤종수;전영수;박찬섭;유현호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.416-418
    • /
    • 2003
  • 한국전력공사에서는 전압원 인버터형 FACTS 기기인 UFPC를 전남 강진군 강진변전소에 설치하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병럴인버터, 40MVA 직렬인버터로 구성되어 총 80MVA 용량이다. 강진 UPFC는 GTO를 이용한 3레벨 인버터 모듈 20MVA 총 4대로 구성되어 있으며, STATCOM, SSSC, UPFC의 3가지 운전모드를 갖는다. 현재 병렬인버터는 강진 모선전압 제어, 직렬인버터는 강진-장흥간의 조류제어에 기여하며, 상용운전 중이다. 본 논문에서는 강진 UPFC의 운전결과 및 효과를 분석하였다.

  • PDF