• Title/Summary/Keyword: Starting characteristics

Search Result 1,097, Processing Time 0.032 seconds

Starting Characterization of Induction Motor using Reactor Tap Change (리액터 탭 절환에 의한 유도전동기의 기동 특성)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • An induction motor is most widely used to obtain driving force in the industrial field. The induction motor is generated a high current at starting. A starting current is often more than five times of rated current. A high starting current can cause problems such as voltage drop in the power system. In order to solve these problems, a reactor starting method has been widely applied in a large motor capacity. There are differences in the operating characteristics of induction motor corresponding the switching time of reactor tap. In this study, I analyzed that current, torque, power of induction motor are different from changing time and tap setting values of reactor tap.

Analysis of Power Condenser Voltage Characteristics by Reactor Starting-operation (리액터 기동 운전시 콘덴서 전압 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Dong-Ju;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.619-620
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Starting power factor is specially low. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is being hit by the effects of the starting reactor connection position. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

  • PDF

Conduction Bar Design to Improve Starting Stability of LSRM (LSRM의 기동 안정성 개선을 위한 도체바 설계)

  • Jung, Tae-Uk;Nam, Hyuk;Eom, Jae-Boo;Eum, Sang-Joon;Jo, Seong-Guk;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1168-1170
    • /
    • 2005
  • This paper deals with the conductor bar design to improve starting stability of line-start synchronous reluctance motor(LSRM). As design variables, the number and the shape of conductor bars of rotor are chosen. The starting characteristics are calculated by finite element method(FEM) and the conductor bars are designed to improve the starting torque according to initial starting rotor position. Finally, the starting characteristic of the designed model are compared with that of the initial model.

  • PDF

A Study on the Starting Characteristics Prediction of Induction Motors (유도전동기의 기동특성 예측에 관한 연구)

  • 전내석;박정환;조성훈;이성근;김윤식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.7
    • /
    • pp.1308-1313
    • /
    • 2001
  • This paper presents methods of parameter measurement and starting characteristics of a 3 phase induction motor. The motor parameters measured by DC test, blocked rotor test, and no load test are used as the input data for computer simulation. Starting characteristics are analyzed through computer simulation using measured parameters, and the simulation results are compared with the experimental results obtained by using strain gauge attached on the motor shaft. It is conformed that the experimental results are very similar to those of the simulation.

  • PDF

Optimal Design for Starting -Torque of Line-Start Permanent Magnet Synchronous Motors (직립 기동 영구자석 동기전동기의 기동토크 최적화 설계)

  • Kim, Byong-Kuk;Moon, Ji-Woo;Kim, Mi-Jung;Lee, Byung-Jun;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1390-1396
    • /
    • 2007
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However, it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor. Finally this paper gives the comparison between the simulation results and the experimental results.

Optimal Design for Starting-Torque of Line Start Permanent Magnet Synchronous Motor (직립 기동 영구자석 동기 전동기의 기동 토크 최적화 설계)

  • Kim, Byong-Kuk;Hwang, Dong-Won;Kim, Tae-Hyun;Jo, Won-Yung;Lee, In-Jae;Han, Sung-Jin;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.930-932
    • /
    • 2005
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

Induction Motor Starting Characterization with Power Factor Correction Capacitors (역률개선 콘덴서를 이용한 유도전동기 기동특성 분석)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.206-212
    • /
    • 2017
  • Induction motor torque is the reactive power is needed which corresponds to the exciting current to generate the magnetic flux as the product of current and flux. For use in the method of supplying the required reactive power to the induction motor power factor correction apparatus using a lot of ways to supply in place of the power supply side, when using a power factor compensation device can reduce the apparent power, the power factor can be improved. However, the distance to the emergency generator transformers or motors from the motor capacity is smaller but short and difficult to maneuver the theory and practice of the operating characteristics of the starting characteristics of the motor used a lot of large industrial plants were measured and analyzed. Therefore, this study investigated the motor starting Analysis and interpretation for the relationship with the large motor starting torque and speed during motor starting.

Comparison of Starting Current Characteristics for Three-Phase Induction Motor Due to Phase-control Soft Starter and Asynchronous PWM AC Chopper

  • Thanyaphirak, Veera;Kinnares, Vijit;Kunakorn, Anantawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1090-1100
    • /
    • 2017
  • This paper presents the comparison of starting current characteristics of a three-phase induction motor fed by two types of soft starters. The first soft starter under investigation is a conventional AC voltage controller on the basis of a phase-control technique. The other is the proposed asynchronous PWM AC chopper which is developed from the conventional synchronous PWM AC chopper. In this paper, the proposed asynchronous PWM AC chopper control scheme is developed by generating only two asynchronous PWM signals for a three-phase main power circuit (6 switching devices) from a single voltage control signal which is compared with a single sawtooth carrier signal. By this approach, the PWM signals are independent and easy to implement since the PWM signals do not need to be synchronized with a three-phase voltage source. Details of both soft starters are discussed. The experimental and simulation results of the starting currents are shown. It is found that the asynchronous PWM AC chopper efficiently works as a suitable soft starter for the three-phase induction motor due to that the starting currents are reduced and are sinusoidal with less harmonic contents, when being compared with the starting current waveforms using the conventional phase-control starting technique. Also the proposed soft starter offers low starting electromagnetic torque pulsation.

An Analysis of Starting Motions in Time 300m Inline Skating (인라인 스케이트 T300m 출발동작 분석)

  • Park, Ki-Beom;Yang, Jeong-Ok;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.123-137
    • /
    • 2003
  • This study is to present more effective starting skills through analysis of kinematic characteristics of starting motions in 300m Time Trials of Inline Skating. To achieve this goal, 6 athletes, 3 in the national team and 3 in business teams were chosen and their starting motions were examined with three-dimensional image analyses. The results of analyses in regard of positions and speed of the bodily center and angles, angular velocity, and linear velocity of articulations of lower limbs by sections of starting motions are as follows: In case of the central position, though it is effective to reduce the air resistance by lowering the upper part of the body maximumly, it is reasonable to accelerate by raising the upper part of the body to some degree for the running posture at the lower speed in the starting section. In the starting section, it is efficient to minimize the period of time in touching the ground. for this, it is necessary to train for taking motions without slippage while touching the ground. While 3 athletes in business teams kicked the ground as running right after the starting, the others in the national team slid on the ground. As the number of steps increased, the movable speed changed quickly. Thus the movable speed of athletes in the national team indicated big differences in two to three steps. If these factors are well supported, the push-away starting method might be better than the running starting method in terms of improvement of records.

The Starting System Implementation of SPIM with Detecting Main Winding Current (주권선 전류검출에 의한 단상유도전동기의 구동시스템 구현)

  • 최낙일;박수강;오금곤;백형래;임양수;오기진
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.166-170
    • /
    • 1997
  • A Single phase induction motor is the predominant fractional horsepower power rated, extensively used in domestic and industrial application. For example, these motors provide the motive power to washing machines, fans, refrigerators, etc. In this paper, single phase induction motor input current was detected by a small current transformer and determined TRIAC gate signal by using op-amp analog circuit. The soft-start strategy is based on limited auxiliary current angle during starting period in the closed-loop control. The Simulation and experimental result show the motor's starting characteristics of the proposal starting system and are compared with centrifugal switch starting motor.

  • PDF