• Title/Summary/Keyword: Start-up Condition

Search Result 142, Processing Time 0.029 seconds

An experimental study on the dynamic characteristics of a residential air-conditioner with a R22 alternative refrigerant (R22 대체냉매 에어컨의 동적 특성에 대한 실험적 연구)

  • Kim, Man-Hoe
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.408-415
    • /
    • 1998
  • This study presents experimental results on the shut-down and start-up characteristics of a residential split-system air-conditioner with capillary tube, using R410A as a R22 alternative refrigerant. During shut-down, the transient characteristics are evaluated by measuring the high side and low side pressures and temperatures of the system. The dynamic behavior of the system after start-up is also investigated at the high temperature cooling test condition. All experiments are performed in psychrometric calorimeter. The cooling capacity, power consumption, dehumidification capacity and cycle characteristics after start-up are analyzed.

Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump (펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰)

  • Heo, Min Woong;Min, Ji Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

Start-up Noise Reduction of Reciprocating Compressor Using Cavity Resonance Analysis (공동 공진해석을 이용한 왕복동식 압축기의 기동소음 저감에 관한 연구)

  • Kim, Min-Chul;Kim, Won-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.2
    • /
    • pp.153-159
    • /
    • 2010
  • This work focuses on finding a method to reduce the noise of a hermetic reciprocating compressor during start-up using an acoustical analysis. The noise of compressor during start-up, which is a higher level than that of a normal operating condition, has transient and non-stationary characteristics. The acoustical analysis of compressor cavity is performed to find an effective method to reduce the noise level. In the acoustical analysis, the shape variations of frequency response function in the neighborhood of resonances are tested for three parameters: the height of remained oil, the suction position of refrigerant and the position of driving part. As a conclusion of this result, to reduce the emission noise of compressor during start-up, the height of remained oil should be kept at 16 mm, the refrigerant should be sucked at the cross point of nodal lines of X and Y directional cavity modes, and the driving part should be positioned in the center of cavity.

Estimation of Occupational Accident Rate about Start-up Establishment and Analysis of Characteristics about Occurrence (신생사업장 재해율 및 재해발생형태 분석)

  • Kim, Young Sun;Koo, Kwon Ho;Choe, Seong Weon;Kwon, Oh Jun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.83-89
    • /
    • 2012
  • In order for start-up establishment to enter the business market, it has to get over the first mover advantage of the existing establishment. As a result, its working condition deteriorates and a great deal of occupational accidents take place. Based on 2009 standard, the occupational accident rate of start-up establishment is 1.28%, which is two times higher than existing establishment and the gap between manufacturing and service industry has been getting wide. For the characteristic of injured person in start-up establishment, it is showed that the occupancy rate of women and people with less than 30 age starting out in a career is high and the occupancy rate of occupational accident for holiday and night work is high. Therefore, the act for occupational accident prevention is needed in the early period of business and underprivileged group for occupational accident.

A Study on the Start-Up Scheme of Direct Vector Controlled Induction Motor System (유도전동기의 직접 벡터제어 시스템에서 기동기법에 관한 연구)

  • 전태원;최명규;유우종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.427-434
    • /
    • 2000
  • The paper proposes a zero speed start-up scheme of direct rector controlled induction motor drive without any torque jerk. At standstill condition, a method is derived to calculate a stator flux with only stator current. The programmable 3-stage low pass filters with programmable time constants is used in order to solute the problem of integration for stator flux estimation in the direct vector control mode. Due to the time delay of 3-stage low pass filter, the status flux decreases rapidly and also the torque jerk occurs during the transition from standstill mode to the direct rector control mode. A feedforward control strategy of the stator flux is suggested to prevent the torque jerk at start-up. Through results of simulation and experiment with 32 bit DSP, the performance of the start-up scheme is verified.

  • PDF

A Study on Cold Start Emission Characteristics using the Syngas in a SI Engine (합성가스를 이용한 SI 엔진의 냉간시동 배기가스 배출특성에 관한 연구)

  • Song, Chun-Sub;Kim, Chang-Gi;Kang, Kern-Young;Cho, Yong-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.66-72
    • /
    • 2008
  • Fuel reforming technology for the fuel cell vehicles could be adopted to internal combustion engine for the reduction of engine out emissions. Since syngas which is reformed from fossil fuel has hydrogen as a major component, it has abilities to enhance the combustion characteristics with wide flammability and high speed flame propagation. In this paper, syngas was feed to 2.0 liter gasoline engine during the cold start and early state of idle condition. Not only cold start HC emission but also $NO_x$ emission could be dramatically reduced due to the fact that syngas has no HC and has nitrogen up to 50% as components. Exhaust gas temperature was lower than that of gasoline feeding condition. Delayed ignition timing, however, resulted in increased exhaust gas temperature approximated to gasoline condition. It is supposed that the usage of syngas in the gasoline internal combustion engine is an effective solution to meet the future strict emission regulations by the reduction of cold start THC and $NO_x$ emissions.

Effect on Vibration of Start-up Condition and Retrofit of Steam Turbines (증기터빈의 기동조건과 성능개선이 터빈의 진동에 미치는 영향)

  • Lee, Hyuk Soon;Chung, Hyuk Jin;Song, Woo Sok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.1-7
    • /
    • 2011
  • The analysis shows that the vibration is one of the main reasons of turbine failure. Especially, the problems caused by vibration occur right after retrofit of the turbine-generator and restarting the turbine. Through the case study of high vibration caused by after the turbine trip and restart, turbine vibration was identified to be influenced by startup condition. Turbine startup at high casing temperature right after unscheduled turbine trip cause radial expansion in rotor by contraction in axial direction, while casing continues to contract by steam flowing into casing. Consequently, gap between rotor and casing decrease until to metal contact to cause high vibration. Through the case study of high vibration of turbine-generator system after generator retrofit, it was identified that generator replacement could cause high vibration in turbine-generator system if the influence of generator replacement on entire system was not considered properly. To prevent startup delay caused by high vibration, it is important to keep the gaps at the design standard and start the turbine after thermal equilibrium.

The Study of the Effects of Nonthermal Plasma-Photocatalyst combined Reactor on Hydrocarbon Decomposition and Reduction during Cold Start and Warm-up in a SI Engine (스파크 점화기관 냉간 시동시 플라즈마 광촉매 복합장치에 의한 탄화수소 화합물 저감에 관한 실험적 연구)

  • Lee, Taek-Heon;Chun, Kwang-Min;Chun, Bae-Hyeock;Shin, Young-Gy
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.169-178
    • /
    • 2001
  • Among the recent research ideas to reduce hydrocarbon emissions emitted from SI engines till light-off of catalyst since cold start are those exploiting non-thermal plasma technique and photo-catalyst that draws recent attention by virtue of its successful application to practical use to clean up the atmosphere using the feature of its relative independence on temperature. Based on the previous research results obtained with model exhaust gases using an experimental emissions reduction system that utilizes the non-thermal plasma and photo-catalyst technique, further investigation was conducted on a production N/A 1.5 liter DOHC engine during cold start to warm-up. For the effects of non-thermal plasma-photocatalyst combined reactor, 10% concentration reduction was achieved with the fuel component paraffins, and the large increase in non-fuel paraffinic components and acetylene concentrations were similar to those of base condition. However the absolute value was locally a bit higher than those of base condition since the products was made from the dissociation and decomposition of highly branched paraffins by plasma-photocatalyst reactor. Olefinic components were highly decomposed by about 75%, due to these excellent decompositions of olefins which have relatively high MIR values, and the SR value was 1.87 that is 30% reduction from that of base condition, then, the photochemical reactivity was lowered.

  • PDF

The Current Situation and Development Strategies of Fashion Start-up Companies : Focused on Rising Fashion Designers in Busan (패션스타트업 기업의 현황과 발전에 관한 연구 : 부산 패션 신진디자이너를 중심으로)

  • Chang, Ji-Yean;Lee, Jin-Hwa
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.2
    • /
    • pp.163-171
    • /
    • 2021
  • The purpose of this study is to examine the current operation condition of fashion start-up companies and the characteristics of their founders in Fashion Creative Studio that is one of government programs supporting fashion start-up of rising fashion designer's brands in Korea and one of supporting facilities. For this purpose, this study surveyed 32 fashion start-up companies founders in Busan Fashion Creative Studio and analyzed the data based on the survey. The results are as follows. First of all, 82% of the founders have experience to start their business in 20s and 60% of founders with not more than 3 to 5 years of work experience related to fashion challenge to start a business. Secondly, major distribution channels of the fashion start-up companies are mainly on-line open-market consisting of 36% and SNS is up to 80% as the main promotion method. In addition, exports to China account for 71% of all exports. Lastly, 33% of businesses consider viral marketing by influencer and 50% of them make plan to export their items to East Asia. It is of research significance that this study can suggest the successful direction of establishing and operating fashion start-up companies through making good use of Fashion Creative Studio, the supporting program including facility.

A Study on the Start-up of the Water/Steam Receiver for Solar Power Tower (타워형 태양열 흡수기의 시동특성에 관한 연구)

  • Seo, Ho-Young;Kim, Jong-Kyu;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.157-160
    • /
    • 2008
  • Solar receiver in the solar power tower system has a similarity to a boiler of the thermal power plant in many aspects. However Boiler is operated long time without stopping while solar receiver repeats start and stop every day. The objective of this study is to investigate start-up characteristics of solar receiver. The experimental device was constructed in a bench scale. Basic experimental condition of water/steam was set by 25 bar and $223^{\circ}C$. Initially, the heat was added into risers only, then another experiment with input into drum additionally was done. When the heat flux was valid only risers, it took about 300 minutes until the water temperature in drum reached $223^{\circ}C$. Water temperature of drum was increased by $44^{\circ}C$/hr with 91.14 g/s of water circulation. With additional heat input into drum, 200 minutes was required to reach $223^{\circ}C$. In this case temperature was increased $66^{\circ}C$/hr with 96.5 g/s of water circulation.

  • PDF