• Title/Summary/Keyword: Standby

Search Result 430, Processing Time 0.023 seconds

A Low-Power Single Chip Li-Ion Battery Protection IC

  • Lee, Seunghyeong;Jeong, Yongjae;Song, Yungwi;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.4
    • /
    • pp.445-453
    • /
    • 2015
  • A fully integrated cost-effective and low-power single chip Lithium-Ion (Li-Ion) battery protection IC (BPIC) for portable devices is presented. The control unit of the battery protection system and the MOSFET switches are integrated in a single package to protect the battery from over-charge, over-discharge, and over-current. The proposed BPIC enters into low-power standby mode when the battery becomes over-discharged. A new auto release function (ARF) is adopted to release the BPIC from standby mode and safely return it to normal operation mode. A new delay shorten mode (DSM) is also proposed to reduce the test time without increasing pin counts. The BPIC implemented in a $0.18-{\mu}m$ CMOS process occupies an area of $750{\mu}m{\times}610{\mu}m$. With DSM enabled, the measured test time is dramatically reduced from 56.82 s to 0.15 s. The BPIC chip consumes $3{\mu}A$ under normal operating conditions and $0.45{\mu}A$ under standby mode.

Performance Analysis of Highly Available Cold Standby Cluster Systems (가용성이 높은 Cold Standby 클러스터 시스템의 성능 분석)

  • Park, Gi-Jin;Kim, Seong-Su
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.28 no.3
    • /
    • pp.173-180
    • /
    • 2001
  • 고가용도 클러스터 시스템에서 가동되는 인터넷 기반 소프트웨어의 복잡도가 증가됨에 따라 소프트웨어의 설계, 구현, 또는 그 밖의 여러 가지 원인과 관련된 결함으로 인하여 시스템 서비스의 오동작 또는 수행 중단으로 이어지는 사례가 늘어나고 있다. 특히 대량 트랜잭션을 처리하는 인터넷 기반 컴퓨팅 소프트웨어는 빈번한 통신 두절과 데이터 유실로 인하여, 이들이 탑재된 클러스터 시스템의 결함 발생이 더욱 심각할 가능성이 높다. 본 연구는 소프트웨어 재활 결함 허용 기법을 활용하여, 별도의 추가되는 하드웨어 없이도 가용도를 개선할 수 있다는 '소프트웨서 재활 기법을 적용한 다중계 시스템 가용도 분석'에 관한 논문에서 언급된 문제점들에 대한 해결 방안을 제시하였으며, 구체적으로는 1) 주서버의 고장 발생시 여분서버로의 작업전이(switchover) 상태를 클러스터 시스템 모델링에 포함시켰으며, 2) 작업전이 상태와 재활(rejuvenation) 상태에서 머무는 시간을 지수분포 대신에 k-stage Erlangian 분포를 사용하여 확정시간(deterministic time)을 표현할 수 있도록 하였다. 즉 본 논문에서는 고가용도 cold standby 클러스터 시스템의 운영 상태에 대한 상태전이도(state transition diagram)에서, 임의의 상태에서 머무는 시간분포가 memoryless 성질을 만족하지 않아도 되는 semi-Markov 프로세스 문제를 해결하였다.

  • PDF

A Case Study of Electric Power Consumption Characteristics in University Building (대학건물의 에너지 소비 특성에 관한 사례분석)

  • Lee, Wang-Je;Lee, Dong-Won;Lee, Jae-Bum;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.90-95
    • /
    • 2012
  • Of school buildings, university building requires various case analysis unlike buildings in the elementary, middle and high schools in accordance with its characteristic for variables such as characteristic of department, construction structure and material, the number of persons admitted and schedule. Through the case research on the 'D' university located in Daejeon, this study made a comparison on the monthly and yearly consumption of gas and electricity of the most recent 3 years and implemented analysis on the usage pattern and standby power of air conditioning and heating by the hour and month using PCCS(Power Consumption Consulting System) as respects electricity that is considered to have a possibility of energy-saving. The result of analysis showed that enormous amount of electric power was used during the night time for freeze protection and burst in winter season and standby power was increased in winter season as a result.

A Case Study of Electric Power Consumption Characteristics in University Building (대학건물의 전력소비 특성에 관한 사례분석)

  • Lee, Wang-Je;Yoo, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.282-287
    • /
    • 2011
  • Of school buildings, university building requires various case analysis unlike buildings in the elementary, middle and high schools in accordance with its characteristic for variables such as characteristic of department, construction structure and material, the number of persons admitted and schedule. Through the case research on the 'D' university located in Daejeon, this study made a comparison on the monthly and yearly consumption of gas and electricity of the most recent 3 years and implemented analysis on the usage pattern and standby power of air conditioning and heating by the hour and month using PCCS(Power Consumption Consulting System) as respects electricity that is considered to have a possibility of energy-saving. The result of analysis showed that enormous amount of electric power was used during the night time for freeze protection and burst in winter season and standby power was increased in winter season as a result.

  • PDF

Smart Multiple-Tap System Based on WiFi for reduction of Standby-Power

  • Jeon, Jeong-woo;Yi, Mira
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.123-129
    • /
    • 2017
  • In this paper, we proposed a smart multiple-tap system which a remote user with smartphone can control multiple-taps in order to reduce standby-power consumption more conveniently when plugged-in electric appliances are turned-off. Recently, several researches of smart multiple-tap using IoT technology has reported. However, in these researches, an additional device like as a server computer is necessary, or multiple-taps could be only remotely controlled by smartphone and not directly controlled by on/off switch. The proposed smart multiple-tap system does not need any additional device only if it has a WiFi router, and it can be used for user as well as remote control using smartphone application and physically direct control using contact switches like existing multiple-taps. Our approach is to develop a smart multiple-tap device capable of WiFi communication can each serve as a server or a client, and can be operated by the hybrid switch combining the on/off contact switch and the relay switch. We implemented the prototype of the proposed system composed of the smart multiple-tap device and the smartphone application, and the test of the prototype validates the proposed system.

Design of Wireless Smart Plug for Energy Sensor Network (에너지 센서 네트워크를 위한 무선 스마트 플러그 설계)

  • Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.2
    • /
    • pp.131-135
    • /
    • 2011
  • In this paper, we describe the design and implementation of wireless smart plug having AC power sensor and intelligent standby power control algorithm for energy sensor network. The adaptive standby power control algorithm has function to apply different threshold of standby power by using learning algorithm depending on electric equipments. As using the proposed algorithm, user convenience will be more better and power consumption can be more reduced. The implemented prototypes of wireless smart plug and wireless access point were tested to verify the required functions and performance. As a result, we confirmed practicality of wireless smart power sensor and satisfaction of given design specifications.

DEVELOPMENT OF A RECONFIGURABLE CONTROL FOR AN SP-100 SPACE REACTOR

  • Na Man-Gyun;Upadhyaya Belle R.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.63-74
    • /
    • 2007
  • In this paper, a reconfigurable controller consisting of a normal controller and a standby controller is designed to control the thermoelectric (TE) power in the SP-100 space reactor. The normal controller uses a model predictive control (MPC) method where the future TE power is predicted by using support vector regression. A genetic algorithm that can effectively accomplish multiple objectives is used to optimize the normal controller. The performance of the normal controller depends on the capability of predicting the future TE power. Therefore, if the prediction performance is degraded, the proportional-integral (PI) controller of the standby controller begins to work instead of the normal controller. Performance deterioration is detected by a sequential probability ratio test (SPRT). A lumped parameter simulation model of the SP-100 nuclear space reactor is used to verify the proposed reconfigurable controller. The results of numerical simulations to assess the performance of the proposed controller show that the TE generator power level controlled by the proposed reconfigurable controller could track the target power level effectively, satisfying all control constraints. Furthermore, the normal controller is automatically switched to the standby controller when the performance of the normal controller degrades.

Alternative Analysis of Reliability Design using Redundancy Technique (리던던시 기법을 활용한 신뢰성 설계 대안 분석)

  • Seo, Yang Woo;Lim, Jae Hoon;Yoon, Jung Hwan;Nam, Hyun Woo;Woo, Yeon Jeong
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • In this paper we proposed the alternative analysis of reliability design using redundancy technique. First, we presented the process for establishing the reliability design alternative analysis process considering the active redundancy and the standby redundancy. and then, the case analysis of A driving equipment was performed in accordance with the reliability design alternative analysis process presented. In case the series reliability design result is not met with the reliability target value. so, the target item for redundancy design of A driving equipment were selected as items with a severity of two or higher. The redundancy design applied with active and standby redundancy techniques were analyzed using BlockSim software. As a result, it was analyzed that reliability design to active redundancy with one of two elements required for A driving equipment is the most efficient compared to the target value of reliability. The results of this study can be usefully used before the reliability design is performed.

Analysis of standby power for enhancing the energy efficiency of a hotel guestroom - Focusing on check-out status - (호텔 객실의 에너지 효율화를 위한 대기전력 분석 - 체크아웃 상태를 중심으로 -)

  • Lee, Junsoo;Koo, Choongwan
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2022
  • The issue of hotel energy use is growing more significant as the hotel industry expands. It is important to take into account the electrical installation and space-specific features in a room unit in order to comprehend the energy consumption of a hotel guestroom. In light of this, this study aimed to analyze standby power for enhancing the energy efficiency of a hotel guestroom during check-out status. This study was conducted in three steps: (i) data collection; (ii) analysis of energy consumption patterns; and (iii) analysis of energy efficiency improvement plan. The main findings of this study can be summarized as follows. First, 32.24% of energy was used in fan coil unit) during check-out status. Second, a hotel guestroom had a 4.30% energy saving potential, based on energy consumption patterns during check-out status. This study can contribute to support hotel management to operate guestrooms differently by helping them identify patterns in energy use and realize potential savings.

Effect of test-caused degradation on the unavailability of standby safety components

  • S. Parsaei;A. Pirouzmand;M.R. Nematollahi;A. Ahmadi;K. Hadad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.526-535
    • /
    • 2024
  • This paper proposes a safety-critical standby component unavailability model that contains aging effects caused by the elapsed time from installation, component degradation due to surveillance tests, and imperfect maintenance actions. An application of the model to a Motor-Operated Valve and a Motor-Driven Pump involved in the HPIS of a VVER/1000-V446 nuclear power plant is demonstrated and compared with other existing models at component and system levels. In addition, the effects of different unavailability models are reflected in the NPP's risk criterion, i.e., core damage frequency, over five maintenance periods. The results show that, compared with other models that do not simultaneously consider the full effects of degradation and maintenance impacts, the proposed model realistically evaluates the unavailabilities of the safety-related components and the involved systems as a plant age function. Therefore, it can effectively reflect the age-dependent CDF impact of a given testing and maintenance policy in a specified time horizon.