• Title/Summary/Keyword: Standards coordinate

Search Result 29, Processing Time 0.026 seconds

Systematic Coordinate Transformation between Different Projection Zones using GPS Survey Results (GPS성과를 매개로 한 구소삼각과 일반원점성과의 계통적 변환)

  • 김감래;최원준;임건혁
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.21-26
    • /
    • 2003
  • The fact on a variety of the plane coordinate systems in cadastral survey field caused a troublesome stage by different standards for the production of cadastral maps. The cadastral maps with different origins are not standardized in terms of unit and coordinate system, which introduces surveying problems at the edges where two or more zones meet. Moreover, difficulties in the creation of seamless digital cadastral map DBs between different coordinate systems has become the obstacle to establish various levels of spatial information systems for the efficient management of Korean Peninsula. Therefore, the aim of the study is to present a way to mutual coordinate transformation by clarifying the systematic differences between the areas of different origins.

  • PDF

Coma Aberration Correction of Optical System by using a Robot Arm Type Coordinated Measuring Machine (로봇팔 타입 삼차원좌표측정기를 이용한 광학계의 비축수차 보정)

  • Chun, Ho Bin;Kim, Goeun;Song, In-Woong;Kang, Hyug-Mo;Rhee, Hyug-Gyo;Ghim, Young-Sik;Yang, Ho-Soon;Kwon, Jong Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.62-66
    • /
    • 2016
  • Optical system needs to be aligned before its undergoing process, is usually shows coma aberrations, which occurred due to imperfection in the lens or other components results in off-axis point sources, appearing to have a tail like a comet. There are some methods to correct coma aberration. In this paper, to correct coma aberration in optical system, using a robot arm type coordinate measuring machine(CMM). CMMs are widely used to measure the form of accuracy of parts and positioning accuracy of systems. Among them, robot arm type CMM has more advantages than the others, such as its mobility and measuring range. However, robot arm type CMM has lower accuracy than cantilever type CMM. To prove robot arm type CMM's accuracy, several factors were suggested in this paper and the final measuring results were compared to a commercial cantilever type CMM. Based on this accuracy, a typical optical system was successfully aligned by using our robot arm type CMM.

Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

  • Dong, Ren G.;Sinsel, Erik W.;Welcome, Daniel E.;Warren, Christopher;Xu, Xueyan S.;McDowell, Thomas W.;Wu, John Z.
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.159-173
    • /
    • 2015
  • The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

A Study on the Current Status and Improvement Plans of Expected Cadastral Coordinate Mapping for Cadastral Confirmation Surveying (지적확정측량을 위한 예정지적좌표도 작성 현황 및 개선방안 연구)

  • Hong, Sung-Eon
    • Journal of Digital Convergence
    • /
    • v.18 no.2
    • /
    • pp.73-81
    • /
    • 2020
  • The purpose of this study is to analyze the current status of expected cadastral coordinate maps by type of district boundary surveying and the problems of non-coincidence with the surrounding land parcels, and to suggest ways to improve them in the future. Currently, the expected cadastral coordinate maps are drawn using various methods such as reference point adjust adjustment, reference point adjust adjustment and present condition, reference point and present condition. As a result, there was a problem of non-coincidence such as overlapping or blanking in expected cadastral coordinate maps for cadastral confirmation surveying and surrounding individual parcels. In addition, detailed unified standards for minimizing the occurrence of non-coincidence problems are lacking. In order to improve the problems analyzed, the study suggested the acquisition and management of digital coordinates for the parcels around the district boundary, the preparation and dissemination of cadastral surveying results determination standard manual for the preparation of expected cadastral coordinate maps, and the preparation of educational programs for cadastral surveying results determination.

Standardization Plan for Activation of Environmental Impact Assessment based on Spatial Information (공간정보 기반 환경영향평가 활성화를 위한 표준화 방안)

  • Jang, Jung-yoon;Cho, Namwook;Lee, Moung Jin
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.433-446
    • /
    • 2019
  • Environmental impact assessment has been performed as preliminary assessment system in order to conserve environment value and minimize negative effect from development. Assessment based on data has been necessary to strengthen objectivity in process of Environmental impact assessment process. Furthermore extended use of spatial information in Environmental impact assessment system has been required through spatial information provided at government level and possibility connected with spatial information in Environmental impact assessment. However spatial information has not been systematically utilized in current Environmental impact assessment. Also the environmental impact assessment workers including assessment government employees, agencies of Environmental impact assessment document and review agencies lack an understanding in the concept of spatial information, so there is limit about their use to efficiently. In order to improve these limits in use of spatial information, this study suggested measures to standardize spatial information (coordinate and attribute table). To do so, based on coordinate and standards certified by the government, this study defined standard coordinates (GRS-80, central datum point, False East: 100000, False North: 200000) and established 9 default items. Lastly, the aforementioned standards were tested for actual environmental impact assessment projects. Standardization measures suggested in this study are expected to contribute to invigorate spatial information utilization in Environmental impact assessment and expand the scope of the assessment.

Vibration Analysis of an Automatic Ball Balancer with Double Races (이중레이스를 갖는 자동평형장치의 진동해석)

  • Lee, Dong-Jin;Jeong, Jin-Tae;Hwang, Cheol-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1093-1102
    • /
    • 2000
  • Dynamic behaviors are analyzed for an automatic ball balancer with double races which is a device to reduce eccentricity of rotors. Equations of motion are derived by using the polar coordinate sys tem instead of the rectangular coordinate system which is used in other previous researches. To analyze the stability around equilibrium positions, the perturbation method is used. On the other hand, the time responses are computed from the nonlinear equations of motion by using a time integration method.

Photoionization of N,N,N',N'-Tetramethyl-p-phenylenediamine in Polar Solvents

  • Min Yeong Lee;Du Jeon Jang;Minyung Lee;Du-Jeon Jang;Dongho Kim;Sun Sook Lee;Bong Hyun Boo
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.4
    • /
    • pp.429-433
    • /
    • 1991
  • The photoinduced electron transfer reactions of N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD) in various polar solvents were studied by measuring time-resolved fluorescence. The temperature dependence on the fluorescence decay rate in acetonitrile, methanol, ethanol and buthanol was carried out to obtain the activation energy and Arrehnius factor for the photoinduced electron transfer reaction. It was found that as the dielectric constant of the solvent increases, the activation energy and the reaction rate increase. This implys that the Arrehnius factor is important in controlling the photoinduced electron transfer reaction rate. In water, TMPD exists in three forms (cationic, protonated and neutral forms) due to the high dielectric constant and strong proton donating power of water. The photoinduced electron transfer reaction was found to be very fast (< 50 ps) and also the long liverd component in the fluorescence decay profile attributable to the photoexcited protonated form of TMPD was observed. Probably, the reaction pathway and the reaction coordinate seem to be different depending on the solvents studied here.

The Study on the Delineation of the Busan Metropolitan Region, Korea (부산광역도시권 설정에 관한 연구)

  • Lee, Hee-Yul;Ju, Mee-Soon
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.167-181
    • /
    • 2007
  • The newly adopted Korea Geodetic Datum (a.k.a. KGD2002) calls for massive reengineering work on geospatial dataset. The main focus of our study is placed on the strategy and system implementations of the required data reengineering with a keen attention to integrated approaches to interoperability, standardization, and database utilization. Our reengineering strategy includes file-to-file, file-to-DB, DB-to-file, and DB-to-DB conversion for the coordinate transformation of KGD2002. In addition to the map formats of existing standards such as DXF and Shapefile, the newly recommended standards such as GML and SVG are also accommodated in our reengineering environment. These four types of standard format may be imported into and exported from spatial database via KGD2002 transformation component. The DB-to-DB conversion, in particular, includes not only intra-database conversion but also inter-database conversion between SDE/Oracle and Oracle Spatial. All these implementations were carried out in multiple computing environments: desktop and the Web. The feasibility test of our system shows that the coordinate differences between Bessel and GRS80 ellipsoid agree with the criteria presented in the existing researches.

  • PDF

A Study on the Improvement of Performance Testing System of Domestic Surveying Equipment (국내 측량장비 성능검사제도 개선방안 연구)

  • MIN, Kwan-Sik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.53-63
    • /
    • 2016
  • In this paper, we proposed the improvements for performance test and surveying equipment regulations, standards, methods and procedures, depending on the need of improving the legal system for surveying equipment in a diverse and sophisticated surveying industry. This research was performed first investigating the existing legal systems(Act on the establishment and management of spatial data, Framework act on national standards, ISO 17123, JIS B 7912) with respect to the surveying equipment performance testing and the research for IOS and KOLAS suggested the improvements on the application for the surveying equipment performance testing standard. More exactly, first, two years were presented for the surveying equipment performance testing cycle considering the precise accuracy of the instrument stability, purpose and frequency of use, etc. Second, the abolition of the measurement distance by grade and the upward or cross-grade adjustment of the single prism standards about the light wave rangefinder and total station were suggested for the improvement on survey equipment performance criteria. Third, since the main function of total station is focused on a three-dimensional coordinate measurement due to the improvement of surveying equipment performance testing, it was proposed to use the precision(repeatability) of the coordinate measuring method as an evaluation method.

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.