• Title/Summary/Keyword: Standard variation

Search Result 1,552, Processing Time 0.025 seconds

압축 착화 기관의 연소 변동 특성에 관한 연구

  • 이창식
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 1987
  • This paper deals with the theoretical prediction and cyclic variation of combustion characteristics in a four stroke, single0cylinder, diesel engine. Theoretical calculations employed a simple empirical model of analysis of energy equation for the thermodynamic system of engine cylinder. The cyclic variation of combustion characteristics is investigated, in term of frequency distribution and standard deviation of peak characteristics, as obtained by combustion analyzer system. The results of theoretical prediction are shown to be in close agreement with the experimental data. The effect of fuel injection timing, engine speed, cooling water temperature, and the compression ratio on the cyclic variations of combustion characteristics were discussed.

  • PDF

A Study on Decreasing of Sliding Noise of a Carbon Film Variable Resistor (탄소 피막 가변 저항기의 접동 잡음 감소에 관한 연구)

  • 윤재강
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.50-54
    • /
    • 1983
  • Contact resistance variation which may be called sliding noise in carbon film variable resistors whose resistance elements consists of linear resistivity distribution were measured with several kinds of sliders and were analyzed to reduce the contact resistance variation. About the measuring method, the standard method of measuring contact resistance variation specified by the variable Resistance Components Institute was adupted. By analyzing the experimental results, it has been shown that the primary cause of contact resistance variation is due to current constriction and small discharge sparks in the resistance film in the area close to the slide contact. Moreover, it has been found that the sliding noise would be reduced by increasing the number of contact points, sliding speed, and pressure, and by using some kinds of insulation oil on the contacting surface. High contact resistance variation is likely to occur in the area of high resistance variation in a logrithmic resistance taper.

  • PDF

Effects of Thermal Conductivities on Temperature History of Massive Concrete Structures (국내 시방서와 ACI 규준 열전달율이 매스콘크리트 온도이력에 미치는 영향)

  • 장동일;손영현;조광현;김광일
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.122-126
    • /
    • 1999
  • In this study, using the temperature history analysis, the influences of the conductive values of wooden form, which are specified by Korean Standard for Concrete and ACI Practice Manual for Concrete, on the temperature history were examined. And, the calculated temperature history is compared with the measured temperature history. In the examination for the influences of the conductive values of wooden form, the value recommended by the Korean Standard can more closely predict the themperature history at the points which the variation of the boundary condition should be considered.

  • PDF

Lactulose Contents in Market Milks (시판 우유중의 Lactulose 함량)

  • 박영희;홍윤호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.4
    • /
    • pp.330-334
    • /
    • 1990
  • The lactulose contents in market milks were analyzed by gas chromatographic method. The method is evaluated for accurac and reproducibility using phenyl-$\beta$-D-glucoside as an internal standard. The response factor(RF) of lactulose of standard mixture was 1.15 the recoveries were 97.4-101.3% and the reproducibility was determined on the coefficeitns of variation 24.8% for pasteurized milk and 4.6-4.9% for UHT milk The lactulose contents of 16 brands of the market milks determined were 5.3-59.7mg/100ml in UHT milk and 1.3-1.8mg/100ml in pasteurized milk.

  • PDF

Uncertainty Analysis of Cross-Correlation Algorithm based on FFT by PIV Standard Images (표준 영상에 의한 FFT 기반 상호상관 PIV 알고리즘의 불확도 해석)

  • Lee, Suk-Jong;Choi, Jung-Geun;Sung, Jae-Young;Hwang, Tae-Gyu;Doh, Deog-Hee
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • Uncertainty introduced by a cross-correlation algorithm based on FFT has been investigated using PIV standard images. The standard images were generated by the Monte Carlo simulation method. Both bias and random errors from the velocity vector have been analyzed with regard to the particle diameter, displacement, and the number of particles. The uncertainty of velocity is evaluated based upon the IS0/IEC standard. As a result, a total error of $0.26\%$ is included in the PIV cross-correlation algorithm. In addition, the uncertainty budget is presented, where the effect of the above three variables is examined. According to the budget, the variation of the number of particles within the interrogation window mainly contributes to the combined standard uncertainty of the real measured velocity field when excluding the effect of errors by the experiments itself. Finally, the expanded uncertainty is found to be about $12\%$ at the $95\%$ confidence level.

  • PDF

The New Design Methodology Considering Transistor Layout Variation (트랜지스터 레이아웃 산포를 고려한 새로운 설계 기법)

  • Doh, Ji Seong;Cho, Jun Dong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.234-241
    • /
    • 2012
  • This paper proposes a novel design methodology considering transistor layout variation. The proposed design technique is to improve the transistor's electrical characteristics without performing a circuit simulation to extract transistor layout variation. There are three advantages in the proposed method. Firstly, there is no need to change the normal design flow used in layout designs. Secondly, there is no need to perform simulation in order to extract the transistor layout variation. Thirdly, early warnings in layout design lead to decreasing the number of post layout simulations. Less post layout simulations will decrease the number of iterations in the design cycle and shorten design period. The number of bad transistors in the early design phase were reduced from 17.8% to 2.9% by applying eDRC environment for layout designers to develop Standard Cell Library.

Standardization of Hydration in the Stratum Corneum Using by Polyols (폴리올을 이용한 각질층 수분량 측정의 표준화 연구)

  • Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • The measurement of hydration level in the surface layer of the skin, stratum corneum (SC), gives important information on the biophysical properties and function of the skin barrier such as softness, flexibility, and healthiness of the skin. But it is difficult to measure a consistent hydration level from a sample to another sample due to individual variations and environmental changes. The aim of this study was to evaluate objective hydration after using various products in the SC. The SC Hydration was measured by capacitance (Corneometer$^{(R)}$, C+K, Germany) on the ventral site of forearm from 40 healthy volunteers. The skin surface was chronologically measured immediately after application of the test products and 3 and 6 hours later. We analyzed the averages of five measurements of each site and used the hydration increase rate for correction on untreated site variation. We found that most polyols including glycerol and butylenes glycol influenced directly the hydration increase rate in the SC previously. In this study, glycerol was used to prepare the standard products from 0 to 20 percents and applied to the same volunteers. The individual standard curve showed linear relation to glycerol concentrations. Based on the the standard curve, hydration of SC was converted into hydration increase rate to glycerol concentrations. The converted glycerol concentrations of products were repetitive and reproducible. In addition, the individual standard curve was used to relate the skin type of each individual. These results suggest that the hydration of the SC standardized regardless of external variation and individual skin condition can explain detailed skin state variation. Further studies will be conducted with other ingredients such as surfactants, lipids and aqueous materials, and with other methods for noninvasive measurement.

Seasonal and Look-directional Variation of X-band SAR Sigma Nought in Mongolian Land Surface

  • Kim, Jae-Hun;Yoon, Sun Yong;Jo, Min-Jeong;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.4
    • /
    • pp.639-647
    • /
    • 2018
  • This paper presents TerraSAR-X and KOMPSAT-5 sigma nought variation according to season and antenna observation configuration in Mongolia. Two types of landcover including bare surface and cropland were examined. The seasonal variation of sigma nought in cropland was about 7 dB and particularly a significant sigma nought reduction occurred after harvest. On the contrary, the Mongolia bare surface provides a consistent sigma nought values for several years with an annual variation less than 2.5 dB of standard deviation. However, the bare soil was relatively sensitive to look-direction (or ascending or descending mode) as well as incidence angle while the cropland was almost independent of antenna look-direction and small incidence angle changes. Although the look-directional variation of bare surface sigma nought was observed in this study, the look-direction anisotropic nature of the surface was not well examined. A further study would be required to account for this feature with various SAR observation configurations.

Investigation of threshold voltage change due to the influence of work-function variation of monolithic 3D Inverter with High-K Gate Oxide (고유전율 게이트 산화막을 가진 적층형 3차원 인버터의 일함수 변화 영향에 의한 문턱전압 변화 조사)

  • Lee, Geun Jae;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.118-120
    • /
    • 2022
  • This paper investigated the change of threshold voltage according to the influence of work-function variation (WFV) of metal gate in the device structure of monolithic 3-dimension inverter (M3DINV). In addition, in order to investigate the change in threshold voltage according to the electrical coupling of the NMOS stacked on the PMOS, the gate voltages of PMOS were applied as 0 and 1 V and then the electrical coupling was investigated. The average change in threshold voltage was measured to be 0.1684 V, and they standard deviation was 0.00079 V.

  • PDF

Manufacture of a Gamma-ray Source using the Neutron Activation and Determination of a HPGe Detector Efficiency (중성자 방사화법을 이용한 감마선원 제조 및 HPGe 검출기 효율 결정)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • In order to save time and money needed in the purchase commonly used gamma-ray standard sources, a new radioactive standard source was manufactured by the neutron activation of some regent in the research reactor HANARO. The source was manufactured with an aqueous solution by mixing and dissolving the irradiated reagents. The manufactured source was compared with a commercial standard source. It was confirmed that it could be used as an efficiency calibration source. Also, in order to compare the variation of efficiency due to the volume difference for various containers used in radioactivity assay, the efficiency variation as a function of sample volume was investigated.