• Title/Summary/Keyword: Standard variation

Search Result 1,555, Processing Time 0.031 seconds

Study of the Behavior of Concrete Slab Track on Earthwork According to the Variation of Train Axle Load and Speed (열차하중, 속도변화에 따른 토공상 콘크리트 슬래브궤도의 거동특성연구)

  • Chun, Hee-Kwang;Kang, Yun-Suk;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6788-6798
    • /
    • 2015
  • In recent high speed rail way, the operating speed of train is enhanced and the introduction of EMU train vehicles is increased. In addition, as expected the demand of the concrete slab track and the trend of design cross-section reduction, the clear behavior of evaluation of internal slab layer is demanded about the variation of design load and speed. The purpose of this study is to evaluate and identify the mechanical behavior pattern of concrete slab track and track-road bed with the variation of axle load and train speed. To this end, the behavior of TCL and HSB was evaluated in according to the variation of axle load and speed. And the analysis results and the data measured TCL strain sensor, which was embedded in TCL slab under installation on Honam high speed railway, was analyzed. The analysis result shows that the strain are increasing in according to the speed-up of train, and line regression was obtained from measured data. Analysis data of the state of bonding condition of slab layer and measured data was analyzed. It is conducted that the TCL layer stress of HEMU 430X, which of axle load, is lighter was similar to the stress of KTX-Honam, the standard deviation of measured stress is dramatically increased.

Archaeomagnetic Secular Variation of the Neolithic Age in Korea: Focusing on the Mid-Western Region Sites (한반도 신석기시대의 고고지자기 변동: 중서부지역 유적을 중심으로)

  • Sung, Hyong Mi
    • Journal of Conservation Science
    • /
    • v.29 no.3
    • /
    • pp.223-229
    • /
    • 2013
  • It is not known in details for the A.D. period as the archaeomagnetic dating method to be fully facilitated in Korea but it has prepared for the revised shape of standard curve to trace the geomagnetic field variation, and there were cases to increase the survey on relics on the B.C. period to find out for the detailed archaeomagnetic field variation on the Bronze Age to the Early Iron Age. Furthermore, the survey cases on the relics on the Neolithic Age began to emerge a little by little archaeomagnetic field variation of the Neolithic Age through 34 pieces of the archaeomagnetic measurement data as making active advancement around mid-western region. Data is insufficient yet that it is difficult to find out the detailed trend of modification but it is estimated for approximate appearance. The archaeomagnetic field variation of the Neolithic Age made changes without breaking away from the scope of changes in the A.D. period as in the same way with the Bronze Age, and comparing to the variation of archaeomagnetic field for the Bronze Age, the magnetic inclination shifted within the scope of having almost no difference, but the declination is shown to skewed toward the east in its overall appearance. In addition, the comparison was made with the data of the Jomon Age in Japan and the archaeomagnetic measurement data of Korea has a little bit more depth for while the declination is skewed toward the east for 10 degree or more compared to those of Japan. However, in the part where the data is concentrated most intensely, the data for both countries has significant part to overlap to each other that the archaeomagnetic field variation of the Neolithic Age of Korea showed overall similar variation with certain partial changes when compared to those of Japan.

Simulation of Temporal Variation of Acoustic Transmission Loss by Internal Tide in the Southern Sea of Jeju Island in Summer (여름철 제주 남부해역에서 내부 조석에 의한 음파 전달손실의 시간적 변화 모의실험)

  • Kim, Juho;Kim, Hansoo;Paeng, Dong-Guk;Pang, Ig-Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.12-19
    • /
    • 2015
  • In this paper, temporal variations of acoustic transmission loss (TL) affected by internal tide are studied by computer simulation using oceanic data measured in the southern sea of Jeju Island in summer. Temperature was measured with depth (bottom depth are nearly 80 m) in two sites near Seogwipo coast every one hour for 25 hours during July 27 and 28, 2009. The periodic fluctuation of temperature due to the internal tide was observed and its vertical displacement was more than 10 m. In order to investigate temporal variation of TL by internal tide, acoustic propagation between two measurement sites (3.8 km distance) was simulated with a source depth of 10 m. TL variation for 1/3 octave band of 100 Hz center frequency highly coincided with tidal period but more complex variation with indistinct tidal period was observed for 1 kHz. Maximun standard deviation of TL variation was 4.2 dB for 100 Hz at 2.8 km distance from a source and it was 3.7 dB for 1 kHz. The tidal variation was also shown in detection range and its maximum variance was less than 1 km. These results imply that temporal variation of TL should be considered for acoustic researches at the southern sea of Jeju Island.

Flatness Characteristics Analysis Technique of Attenuator Using Thermal Voltage Converter and AC Measurement Standard (열전압변환기와 교류측정표준을 사용한 감쇠기 평탄도 특성 분석 기법)

  • Cha, Yun-bae;Kim, Boo-il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.330-337
    • /
    • 2018
  • This paper proposes a technique to analyze the flatness characteristics of the attenuator at 10Hz to $50\text\tiny{MHz}$ on the basis of $1\text\tiny{kHz}$ using a Thermal Voltage Converter and AC measurement standard. In the proposed technique, the input voltage of the attenuator for each measuring frequency is supplied at the same rate as $1\text\tiny{kHz}$ using TVC, and the flatness characteristics of the attenuator are analyzed by the voltage variation indicated in the AC measurement standard. The results of the analysis of the attenuator flatness characteristics show that the maximum uncertainty of $866{\mu}V/V$ can be measured from $10\text\tiny{dB}$ to $70\text\tiny{dB}$ and the uncertainty is reduced by about 37% compared to $2.31\text\tiny{mV}$/V using the network measurement method. The improved attenuator flatness characteristic values can be applied to the frequency flatness calibration from 2.2V to 2.2mV at the low voltage of the AC measurement standard.

A Study on the Image of the Girls' High School Uniform Design (여고생의 교복 디자인에 따른 이미지 연구)

  • Yang, Eunjin;Jeong, Sujin
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.18 no.2
    • /
    • pp.237-251
    • /
    • 2016
  • The purpose of this study is to provide the improvement idea for an school uniform styling that better satisfies female high school students' changing demands, through evaluating images differences according to design variation in school uniforms. This study was carried out with a between-subject design by using the stimulant materials of school uniform design and image assessment scale. The stimulant materials used for this study were 27 designs with blazer/skirt ensemble and 21 designs with vest/skirt ensemble. The survey materials were collected through a questionnaire from a total of 192 female high school students living in Gyeongsangnam-do. As a result of analyses on a image of blazer/skirt ensembles, 4 factors were extracted such as neatness, uniqueness, activeness, and attractiveness. Blazer was the only variables that exerted significant effects on neatness, uniqueness, and attractiveness. As a result of analyses on a image of vest/skirt ensembles, 4 factors were extracted such as attractiveness, neatness, uniqueness, and activeness. Skirt was the only variables that exerted significant effects on attractiveness, neatness, and uniqueness. Neat image was perceived to be high in ensembles of standard blazer/standard collar/horizontal-seam skirt, standard vest/skirt with horizontal color combination, and buttons-down vest/horizontal-seam skirt. Unique image was perceived to be high in ensembles of blazer with bindings/standard collar/solid skirt, and vest with pockets/skirt with vertical bindings. Also, active image was perceived to be high in ensembles of vest with pockets/skirt with vertical bindings, and buttons-down vest/skirt with vertical bindings. Attractive image was perceived to be high in ensembles of blazer with bindings/peaked lapel/skirt with vertical bindings, and standard vest/horizontal-seam skirt. In conclusion, this study reveals that different items and pieces of school uniforms can be combined in many different ways to create quite diverse looks. Thus, this study provides important basic data for research on teenagers' fashion and clothing.

  • PDF

The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone (표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성)

  • Chung Se Young;Chung Hui Young;Kim Young Bum;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

A Standard Guide to Physical Oceanographic Survey of the Effect of Thermal Discharge from a Nuclear Power Plant (원자력발전소 온배수 영향 해양물리분야 조사의 표준지침)

  • Lee, Jae-Hak;Ro, Young-Jae;Cho, Yang-Ki
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2007
  • The methods of physical oceanographic surveys to examine the effect of thermal discharge from nuclear power plants in Korea have been reviewed and a standard guide to the survey is proposed. It is desirable that in situ observation and numerical thermal diffusion modeling are conducted simultaneously to describe the variation in temperature distribution affected by thermal discharge from a power plant because any observation or numerical modeling alone has limits to do so quantitatively. It is suggested that the field observation must be based on the concept of heat budget modeling considering all artificial and natural heat sources/sinks around the power plant. Any results from numerical modeling must reach to a certain statistical significance level to use for a standard temperature distribution. In addition, the development of standard numerical codes is proposed to improve the problems shown in the past numerical circulation and diffusion modelling.

Replica Technique regarding research for Bit-Line tracking (비트라인 트래킹을 위한 replica 기술에 관한 연구)

  • Oh, Se-Hyeok;Jung, Han-wool;Jung, Seong-Ook
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.167-170
    • /
    • 2016
  • Replica bit-line technique is used for making enable signal of sense amplifier which accurately tracks bit-line of SRAM. However, threshold voltage variation in the replica bit-line circuit changes the cell current, which results in variation of the sense amplifier enable time, $T_{SAE}$. The variation of $T_{SAE}$ makes the sensing operation unstable. In this paper, in addition to conventional replica bit-line delay ($RBL_{conv}$), dual replica bit-line delay (DRBD) and multi-stage dual replica bit-line delay (MDRBD) which are used for reducing $T_{SAE}$ variation are briefly introduced, and the maximum possible number of on-cell which can satisfy $6{\sigma}$ sensing yield is determined through simulation at a supply voltage of 0.6V with 14nm FinFET technology. As a result, it is observed that performance of DRBD and MDRBD is improved 24.4% and 48.3% than $RBL_{conv}$ and energy consumption is reduced which 8% and 32.4% than $RBL_{conv}$.

Variation in Nutritive Value of Commercial Broiler Diets

  • Ru, Y.J.;Hughes, R.J.;Choct, M.;Kruk, J.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.6
    • /
    • pp.830-836
    • /
    • 2003
  • The classical energy balance method was used to measure the apparent metabolisable energy (AME) of four batches of broiler starter and finisher diets produced by two commercial feed companies. The results showed there was little variation in protein content between batches, but NDF content varied from 13.3% to 15.5% between batches of diet. The batch variation in chemical composition differed between feed manufacturers. While there was no difference in AME and feed conversion ration (FCR) between batches of starter diets produced by company A, FCR and AME ranged from 1.76-1.94 (p<0.001) and 11.38-11.90 MJ/kg air dry (p<0.05), respectively, for diets produced by company B. Similar results were found in a second experiment. There was no difference in AME, dry matter digestibility (DMD) and FCR between batches for finishing diet produced by company B, but a large variation occurred for the finisher diets from company A (p<0.01), where the ranges of FCR, AME and DMD were 1.95-2.30, 10.5-12.3 (MJ/kg air dry) and 58-68%, respectively. FCR was correlated with AME. AME was negatively related to the content of fibre in the diet, but positively related to DMD. The preliminary results based on 24 samples showed that near infrared spectroscopy (NIR) has the potential to predict FCR, intake, AME and DMD of commercial broiler diets, with $R^2$ being 0.93, 0.89, 0.95 and 0.98, respectively. The standard error of cross validation was below 0.2 for AME and only 0.06 for FCR.

Characteristics of Workers'Exposure Concentration and Daily Variations to Organic Solvents in Shipbuilding Painting Processes (조선소 도장작업 노동자 유기용제 노출과 일간 변이)

  • Ahn, Jinsoo;Park, Dooyong;Kang, Taesun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.488-499
    • /
    • 2019
  • Objectives: This study was conducted to identify the characterization of organics solvent exposure among painting workers in the shipbuilding painting process, especially for their daily variations(within worker variance). Methods: Charcoal passive dosimeters were worn throughout each work shift for 20 days for five painting workers from October 19 to November 26, 2015. A total of 100 samples were collected, analyzed and compared with statutory workplace environmental measurements. Results: The geometric mean(GM) and geometric standard deviation(GSD) of mixed organic solvent(six substances) exposure index(EI) for the 100 samples were 0.42 and 4.42 respectively. The median and range of GSD for within worker EI representing five workers' daily EI variation is 3.72 and 2.63 ~ 5.20, respectively, which is classified as a very large variation(GSD>3). We were able to divide the painting process into two similar exposure groups(SEGs), Touch-up and Spray. Spray painting workers were much more exposed to organic solvent than Touch-up painting workers(GM=0.71 vs. 0.19), but less variably (GSD=3.64 vs. 4.10). xylene is the substance to which the workers were most exposed(GM=16.19 ppm, GSD=4.36), and the exposure characteristics of six substances including xylene is similar to those of EI. Conclusions: The daily variation of organic solvent exposure in the shipbuilding painting process is so high that statutory Assessment of Reliability of Work Environment Monitoring needs to be conducted with statistically sufficient number of samples and evidence.