• Title/Summary/Keyword: Standard variation

Search Result 1,555, Processing Time 0.042 seconds

Quantitative Evaluation on Optimal Scan Time of PET/CT Studies Using TOF PET (TOF 기법을 이용한 PET/CT 검사에서 적정 스캔 시간에 대한 정량적 평가)

  • Moon, Il-Sang;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2012
  • Purpose: To verify the optimal scan time per bed for clinical application, we evaluated the quality of $^{18}F$-FDG images with varying scan times in a phantom and 20 patients with 38 lesions using a Philips (TOF) PET/CT scanner. Materials and Methods: The PET/CT images of a NEMA IEC body phantom and 20 patients (16 males, 4 females) were acquired for 5 different scan times of 20-100 sec per bed with intervals of 20 sec. The activity ratio of hot spheres (diameter of 17 [H1], 22 [H2] and 28 [H3] mm) to the background region in the IEC body phantom was 8-to-1. The contrast recovery coefficient (CRC) and standard uptake value (SUV) based on ROIs of hot spheres and background region were calculated. The noise in each background region was estimated as the ratio of SD of counts to the mean counts in the background region. On the patient image, the injected dose of $^{18}F$-FDG was $444{\pm}74$ MBq and the SUVs in the 38 hot lesions were measured. Results: The two scan time groups (LT-60 [<60 sec] and GT-60 [${\geq}60$ sec]) were compared. In the phantom study, the coefficient of deviations (CVs, %) of CRC and SUV in LT-60 (H1: 14.2 and 7.3, H2: 11.4 and 7.8, H3: 4.9 and 3.2) were higher than GT-60 (H1: 8.9 and 2.8, H1: 8.2 and 5.0, H3: 2.0 and 1.6). In the patient study, the mean CV of CRC and SUV in LT-60 (4.0) was higher than GT-60 (1.2). Conclusion: This study showed that noise increased as the scan time decreased. High noise for the scan time <60 sec per bed yielded high variation of SUV and CRC. Therefore, considering PET/CT image quality, the scan time per bed in the TOF PET/CT scanner should be at least ${\geq}60$ sec.

  • PDF

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

Enzyme Linked Immunosorbent Assay for the Detection of Antibody to Avian Infectious Bronchitis Virus (효소면역법에 의한 닭 전염성 기관지염 바이러스 항체검사)

  • 송현제;최정옥
    • Korean Journal of Poultry Science
    • /
    • v.18 no.3
    • /
    • pp.183-196
    • /
    • 1991
  • In order to establish ELISA method to detect antibody against IBV various factors involved were examined. Antigen was prepared from Massachusetts type IBV which is known to be one of serotypes distributed most widely. The virus was grown in embryonated SPF chicken eggs. Allantoic fluid harvested was processed to ultracentrifugation and sucrose density gradient centrifugation to produce a purified antigen The antisera selected from the field samples based on hemagglutination inhibition test were used as the standard positive and negative sera for this study and the results obtained were summarized as follows. 1 , It was found that ELISA test was satisfactory when the purified antigen was coated on the plate in the amount of about 40ng protein per well. In case of the phospholipase treated hemagglutinating antigen it gave satisfactory results when the each well wns coated with 1.2 to 2.5 hemagglutinating unit which was equivalent to 40 to 90ng of protein. 2. There was no significant difference in the ratio of optical density of positive to that of negative serum whether the coated antigen was held for 1 hour at 37$^{\circ}C$ or it was held overnight at 4$^{\circ}C$. The coated antigen could be kept in dried state without change of antigenecity for at least one month of experimental period at 4$^{\circ}C$. 3. There was a big variation in the optical density and P/N values depending on the maker of the plates and on the plate of the same maker. 4. It was found that background optical density was negligible when serum was diluted more than 1:50 and serum dilution of 1:100 appeared to be appropriate as a routine test dilution to screen the antibody. 5. Optical density was fairly constant 15 minutes afterward from the time substrate was treated and during the 4 hours after stopper was treated. 6. There was a low correlation(r=0.42) between ELISA and HI test. However, when 74serum samples were tested for the IBV antibody, 98.7% were found to be positive by both tests in which titers of 2$^{6}$ or more by HI test and P/N values of 1.4 or more by ELISA were considered to be positive, 7 Day-old IBV vaccinated chickens shows a similar antibody decay and rising pattern until 8 weeks of age by the two tests, ELISA and HI.

  • PDF

A Study on the Effect of the Changes of Play Facilities on Rules Changes - Focusing on the City of Seoul - (관련법규 변천이 아파트단지 내 어린이놀이터 변화에 미치는 영향 연구 - 서울시 소재 현장을 중심으로 -)

  • Kim, Dong-Chan;Suh, Joo-Hwan;Park, You-Jeong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.26-35
    • /
    • 2009
  • This study is an analysis of the design changes of children's play facilities and the related rules and regulations which causes these changes. Accordingly, it is noticed that a site's change of design by legislation and by yearly alternation influences playground design. First, after revising the provisions for the distance from roads and parking lots, the constructing of safety fences between play facilities and the using of durable materials, alterations of the designs have been made a reality. Second, the design changes after the period of regulation transitions were caused by provisions related to the shelter of evergreens and conditions of the sun. Third, the changes of the playgrounds were related to the substitution of exercise facilities for the local residents and in carrying out a hygiene exam more than twice a year. Because a lack of regulatory standards for the design of playgrounds resulted in compliance based on individual interpretation and because a substitution of exercise facilities is part of the way to alleviate these regulations, the conditions of the site under investigation could be projeced. By such changes of regulations and analysis of alterations of playground design, programs for improvement were suggested. It turned out that the composition of the concrete standard in conformity with regulations required closer observance. Moreover, design standards for children's playgrounds are needed, such as the provision of variation in external appearance, the creation of more flexible layouts and the outlining of spaces by themes.

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy (3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석)

  • Seong, Yeol-Hun;Rhim, Jae-Dong;Lee, Jae-Hyun;Cho, Sung-Bong;Woo, Dong-Chul;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.256-262
    • /
    • 2008
  • To evaluate the metabolic changes in normal adult brains due to alterations SENSE and NEX (number of excitation) by multi voxel MR Spectroscopy at 3.0 Tesla. The study group was composed of normal volunteers (5 men and 8 women) with a mean ($\pm$ standard deviation) age of 41 (${\pm}11.65$). Their ages ranged from 28 to 61 years. MR Spectroscopy was performed with a 3.0T Achieva Release Version 2.0 (Philips Medical System-Netherlands). The 8 channel head coil was employed for MRS acquisition. The 13 volunteers underwent multi voxel spectroscopy (MVS) and single voxel spectroscopy (SVS) on the thalamus area with normally gray matter. Spectral parameters were as follows: 15 mm of thickness; 230 mm of FOV (field of view); 2000 msecs of repetition time (TR); 288 msecs of echo time (TE); $110{\times}110$ mm of VOI (view of interest); $15{\times}15{\times}15$ mm of voxel size. Multi voxel spectral parameters were made using specially in alteration of SENSE factor (1~3) and 1~2 of NEX. All MRS data were processed by the jMRUI 3.0 Version. There was no significant difference in NAA/Cr and Cho/Cr ratio between MVS and SVS likewise the previous results by Ross and coworkers in 1994. In addition, despite the alterations of SENSE factor and NEX in MVS, the metabolite ratios were not changed (F-value : 1.37, D.F : 3, P-value : 0.262). However, line-width of NAA peak in MVS was 3 times bigger than that in SVS. In the present study, we demonstrated that the alterations of SENSE factor and NEX were not critically affective to the result of metabolic ratios in the normal brain tissue.

  • PDF

Comparison of Sampling Methods for On-Farm Use Quick Test Procedure of Soil Nitrate (토양의 질산태질소 현장검정을 위한 시료 채취방법 비교)

  • Kang, Seong-Soo;Kim, Ki-In;Chung, Keun-Yook;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.1
    • /
    • pp.32-37
    • /
    • 2005
  • The procedure of soil sampling for on-farm quick test of soil nitrate is very important to improve practical application without weighing or drying soil. To improve application of test strip reflectometer as a quick on-farm analytical procedure for the estimation of soil nitrate concentration, three sampling methods such as gravimetric sampling (GS), particle density sampling (PDS) and bulk density sampling (BDS) for on-farm analytical procedure were investigated with twelve soils of 45 to $281mg\;kg^{-1}$ nitrate nitrogen concentration. The nitrate nitrogen concentrations measured from different soils were compared with two analytical methods, ion electrode method as a standard laboratory analysis (SLA) and test strip reflectometer at three moisture conditions, viz. air dried soil, 20 and 40% of maximum water holding capacity (MWHC). Nitrate nitrogen concentration measured by test strip reflectometer was significantly correlated with that of SLA, and the coefficients of variation (CV) were in the range of 3.5 to 10.9%. These CV values less than 10.9% were thought to be acceptable for the measurement of soil nitrate as an on-farm real time analytical procedure. The nitrate nitrogen concentration by BDS for test strip reflectometer as well as ion electrode method was more similar to that of SLA compared with those by GS and PDS especially in case of moist soils. This result suggests that the BDS is more useful than GS and PDS in case of on-farm analytical procedure of soil nitrate for moist soils. Further the practical measurement by BDS could be improved by substituting the bottle cap with a larger container.

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

Impact of Pulmonary Vascular Compliance on the Duration of Pleural Effusion Duration after Extracardiac Fontan Procedure (수술 전 폐혈관 유순도가 심장 외 도판을 이용한 Fontan 수술 후 늑막 삼출 기간에 미치는 영향)

  • Yun Tae-Jin;Im Yu-Mi;Song Kwang-Jae;Jung Sung-Ho;Park Jeong-Jun;Seo Dong-Man;Lee Moo-Song
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.579-587
    • /
    • 2006
  • Background: Preoperative risk analysis for Fontan candidates is still less than optimal in that patients with apparently low risks may have poor surgical outcome; prolonged pleural drainage, protein losing enteropathy, pulmonary thromboembolism and death. We hypothesized that low pulmonary vascular compliance (PVC) is a risk factor for prolonged pleural effusion drainage after the Fontan operation. Material and Method: A retrospective review of 96 consecutive patients who underwent the Extracardiac Fontan procedures (median age: 3.9 years) was performed. Fontan risk score (FRS) was calculated from 12 categorized preoperative anatomic and physiologic variables. PVC $(mm^2/m^2{\cdot}mmHg)$ was defined as pulmonary artery index $(mm^2/m^2)$ divided by total pulmonary resistance $(W.U{\cdot}/m^2)$ and pulmonary blood flow $(L/min/m^2)$ based on the electrical circuit analogue of the pulmonary circulation. Chest tube indwelling time was log-transformed (log indwelling time, LIT) to fit normal distribution, and the relationship between preoperative predictors and LIT was analyzed by multiple linear regression. Result: Preoperative PVC, chest tube indwelling time and LIT ranged from 6 to 94.8 $mm^2/mmHg/m^2$ (median: 24.8), 3 to 268 days (median: 20 days), and 1.1 to 5.6 (mean: 2.9, standard deviation: 0.8), respectively. FRS, PVC, cardiopulmonary bypass time (CPB) and central venous pressure at postoperative 12 hours were correlated with LIT by univariable analyses. By multiple linear regression, PVC (p=0.0018) and CPB (p=0.0024) independently predicted LIT, explaining 21.7% of the variation. The regression equation was LIT=2.74-0.0158 PVC+0.00658 CPB. Conclusion: Low pulmonary vascular compliance is an important risk factor for prolonged pleural effusion drainage after the extracardiac Fontan procedure.

Establishment of Pre-Harvest Residue Limit for Pyrimethanil and Methoxyfenozide during Cultivation of grape (포도(Vitis vinifera L.) 중 Pyrimethanil 및 Methoxyfenozide의 생산단계 잔류허용기준 설정)

  • Kim, Ji Yoon;Woo, Min Ji;Hur, Kyung Jin;Manoharan, Saravanan;Kwon, Chan-Hyeok;Hur, Jang Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • The present study was aimed to predict the pre-harvest residue limits (PHRLs) of pyrimethanil (fungicide) and methoxyfenozide (insecticide) in grape, and to estimate their biological half-lives and residual characteristics. The pesticides were sprayed once on grape in two different fields 10 days before harvest. At the end of 0, 1, 2, 3, 5, 7 and 10 days after application, samples were harvested for further analysis. The residual pesticides were extracted with acetonitrile and partitioned with dichloromethane, and the high-performance liquid chromatography with diode array detector (HPLC/DAD) was employed for the residue analysis. The results obtained in the present study show that the limit of detection of both pesticides were found to be $0.01mg\;kg^{-1}$. The recoveries of these pesticides were ranged between 80.6% and 102.5% with coefficient of variation lower than 10%. The biological half-lives of both pesticides were observed in field 1 and field 2 which shows 7.7 and 7.4 days for pyrimethanil and 5.1 and 6.1 days for methoxyfenozide, respectively. Further, the PHRL of pyrimethanil and methoxyfenozide was found to be $8.90mg\;kg^{-1}$ and $5.51mg\;kg^{-1}$, respectively at 10 days before harvest. Consequently, the present study suggests that the residual amounts of both pesticides will be lower than the maximum residue limits (MRLs) when grape is harvested.