• Title/Summary/Keyword: Standard variation

Search Result 1,552, Processing Time 0.029 seconds

A Study on the appropriateness of Public Facilities Scale (기능전환에 따른 동사무소 공간의 적정규모에 관한 연구)

  • Lee Jeong-Ho
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.65-72
    • /
    • 2005
  • With the changing consciousness of community people and the rising standard of living, there has recently been an emphasis on the creation of public facilities' new functions and their role as local community facilities. This changing trends are accordingly requiring a change in spatial structure of the public facilities. In this study, an analysis was conducted with 24 public facilities situated in the Buk-gu district of Daegu to identify the adequacy of their space scale after functional variation. The results of this study are summarized as follows. 1) The site area of public facilities has been being widened after functional variation since more spaces are needed to provide an outdoor resting space with community people, expand a parking space, and operate a community center. 2) The factors that had a direct effect on the change in the use of space are the reduced space for administrative work and the expanded scope of the community center's function. Specifically, the areas of activities for civil service and administrative work and for reserve forces have been reduced due to reduction of function, and floor division by each function group has been becoming stricter due to addition of a community center's function. 3) It was shown that in terms of the space for functions of public facilities, spaces for civil service and waiting have increased mostly after function variation. After functional variation, the scale of spaces for civil service and administrative work has been being planned within the range of $200\~300 m^2$, regardless of the number of population to be covered by public facilities. 4) The space for public use is showing the greatest increase in public facilities which have been built after functional variation. The major factors seem to be the increased moving passages, the expanded convenient facilities for community people, and the increased convenient facilities for disabled. Facilities scale plans have been being made more systematically, compared to the conventional facilities.

Measurement of Blood Flow Variation using Impedance Method (임피던스법을 이용한 혈류량 변화 측정)

  • Jeong Do-Un;Kang Seong-Chul;Jeon Gye-Rock
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.693-696
    • /
    • 2006
  • In this study, we made the system to measure variation of blood flow using bio-electrical impedance analysis method. The system, which could measure variation of impedance according to pressure change by artificial pressure, consists of pressure measurement and impedance measurement by 4-electrode method. Pressure measurement splits into semiconducting pressure sensor and electronic circuit for processing output signal. In addition, impedance measurement splits into constant current source circuit and lock-in amplifier for detection impedance signal. We experimented feature of impedance measurement using standard resistance to evaluate the system characteristic. As well as, we experimented to estimate variation of blood flow by measuring impedance and blood flow resistance ratio using mean arterial pressure and variation of blood flow with experimental group. As result of this study, blood flow resistance ratio and variation of blood flow were definitely in inverse proportion and were -0.96776 as correlation coefficient by correlation analysis.

  • PDF

Relations between Seed Vigor Criteria and Field Performance in Malting Barley (맥주보리의 종자세 검정치와 포장성적과의 관계)

  • Kim, Seok-Hyeon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.6
    • /
    • pp.656-664
    • /
    • 1996
  • Three malting barley cultivars, Sacheon #6, Doosan #12, and Doosan #22 were collected from Gwangsan, Chinju and Milyang which were artificially aged to provide varying levels of seed quality. Samples were evaluated by the standard germination test (SGT), cold germination test (CT), electroconductivity test and tetrazolium vigor test (TZ). In a multiple regression analysis, percent germination in the SGT accounted for 65% of the variation in field emergence of malting barley. Vigor index of the standard germination and cold germination tests also contributed significantly to the regression equation. Grain yield was predicted by the vigor index of TZ test. Percent standard germination and percent TZ germination prediction were useful for predicting grain yield in nine lots of malting barley.

  • PDF

A field survey on the standard establishment of wearing under environmental thermal conditions II - With emphasis on yearly change of wearing and clothing weight - (환경온도조건하의 착의표준설정에 관한 조사연구(ll))

  • 심부자
    • Journal of the Korean Home Economics Association
    • /
    • v.23 no.4
    • /
    • pp.33-54
    • /
    • 1985
  • The purpose of this study is to establish the suitable wearing standard under environmental thermal conditions in Pusan. The data is obtained from 50 girl students from April, 1984 to March, 1985. Items of the research are as follows : Environmental conditioni, clothing weight, contents of wearing, clothing climate, wearing order etc. RESULTS : 1. The upper clothing wights are varied considerably with temperature, while the lower are not. 2. The outdoor temperature and the total clothing weights show the high negative correlation of r=-.97 wth regression equation of Y=-37.64X+1692.66. 3. The clothing weight per clo is 390g/$m^2$. 4. Mostly, subjects were 2~7kinds of the upper and 3~5kinds of the lower clothing. 5. The clothing weights on the upper part of the body are heavier than those on the lower part of it. 6. The standard deviation of the obver clothing is larger than that of the under clothing. 7. The clothing shape of comfort-sensation reporter changes with variation of temperature. 8. The clothing climate of the inner layer is 32.26$\pm$$0.5^{\circ}C$ in temperature, 43.6$\pm$7% in humidity at four seasons. 9. It is represented that total subjects and comfort-sensation reporter control the wearing contents suitably for temperature. 10. The standard of wearing in Pusan is established as Fig. 6.

  • PDF

A Study on the Evaluation of Long Term Stability of Brinell Standard Hardness Tester and Automatic Indentation Measurement System and Optimum Test Condition (브리넬 경도 표준 시험기 및 압입자국 자동 측정 장치의 장기 안정도 평가와 최적 시험조건에 관한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung;Hwang, N.M.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.1
    • /
    • pp.10-15
    • /
    • 2000
  • Evaluation of long term stability of the Brinell standard hardness tester was carried out to secure its application as a national standard in Brinell hardness. Accuracy and repeatability in load application were tested through evaluating errors in hardness measurement of certified reference blocks. All of those requirements in KS as well as ISO specifications were satisfied by this standard hardness tester. In addition to this, long term stability test of automatic indentation measurement system was carried out. The scattering range was almost the same with its error range. To figure out an optimum test condition for better repeatability and long term stability, the effect of load variation, load application speed and time have been studied using orthogonal array experimental plan. It was found that the best combination is $30{\mu}m/s$ of load application speed and 25 seconds of load application time.

  • PDF

A Study on the Architectural Design Standard for Elementary School in China (중국 소학교 건축설계규범의 구성에 관한 연구)

  • Son, Suk-Eui;Kim, Seung-Je
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.6
    • /
    • pp.77-84
    • /
    • 2018
  • China has been pursuing continuous education reforms in order to complement the shortcomings of traditional education and to prepare for a new era in accordance with the development of the economy and society. School facilities were rapidly increased due to rapid population growth in the 60s and 70s, but the quality of the school facilities was low considering the efficiency and economy, and the regional variation was serious. The National Standard for School Design was enacted in 1986. Since then, we have proposed a new national standard in 2011 in accordance with social change and educational needs, and it has reached the present time. The purpose of this study is to analyze the main contents of "Code for design of school(GB50099-2011)" which is a standard study for Chinese school design as a basic study to understand changes in school architecture in China.

Ecotoxicity Assessment of Potassium Hydrogen Phthalate and Verification of Standard Reference Toxicity Test Method Using Potassium Hydrogen Phthalate

  • Dong Jin Choi
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.4 no.1
    • /
    • pp.49-62
    • /
    • 2023
  • Phthalates are animal carcinogens. Potassium hydrogen phthalate (KHP), which has the least complicated structure among phthalates, is used for the analysis of total organic carbon and formaldehyde. However, its toxicity has not been confirmed. A 24-hour acute toxicity test was performed using Daphnia magna, a water flea used to evaluate aquatic toxicity owing to its high sensitivity. The lowest observed effect concentration of KHP was found to be 240 mg/L. The effects of phosphorus, nitrogen, and Cr(6+), which are able to be discharged along with KHP, were also confirmed using tests. At 240 mg/L KHP, toxicity increased as phosphorus, nitrogen, and Cr(6+) increased. In addition, tests were performed to confirm the half maximal effective concentration of KHP. Through 10 test repetitions, the average ecotoxicity value was found to be 0.3, the average half maximal effective concentration was 327.75 mg/L, and the coefficient of variation (%) was 3.16%; because the latter value is lower than 25%, which is what is generally suggested for the water pollution standard method, the reproducibility of the tests is sufficient to replace the existing standard reference toxicity test that uses potassium dichromate. In addition, the half maximum effective concentration of potassium hydrogen phthalate is approximately 218 times more than that of potassium dichromate; therefore, toxicity is relatively low. In conclusion, KHP is a feasible alternative to the highly toxic potassium dichromate for performing the standard reference toxicity test.

Harmony Matters in Alarm Design: Investigating the Impact of Consonance on Alarm System

  • Ilgang Mukko Lee;Yunsun Alice Hong;Juhyun Jay Lee;Kwanghee Han
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.4
    • /
    • pp.406-416
    • /
    • 2023
  • Alarm system performance is a critical aspect of safety. While existing research has extensively examined the influence of acoustic attributes on alarm performance, consonance's impact remains largely uncharted territory. This study bridges this research gap by investigating the effect of consonance on alarm systems. We extend our investigation to encompass not only the sound characteristics of the alarm but also the acoustic qualities of the surrounding environment, recognizing their potential impact on alarm efficacy. Prior studies consistently link consonance to annoyance levels, resulting in a negative user experience. Thus, we explore the relationship between consonance and alarm system performance, with a particular focus on modulating annoyance as an explanatory factor. Utilizing an oddball paradigm, we categorized standard and oddball sounds into consonant and dissonant types, creating four sound combinations. Participants were asked to respond to the irregularly presented oddball sounds while ignoring the constantly presented standard sounds. Our results reveal significant differences between groups, with the Standard Consonant/Oddball Dissonant (SC/OD) group displaying notably slower response times than the Standard Dissonant/Oddball Consonant (SD/OC) group. This reaction time variation aligns with differences in annoyance levels, as the SC/OD group reports higher annoyance, suggesting that reaction time discrepancies may be linked to increased arousal due to heightened annoyance.

A Study on the Sleeve Form Variation According to Arm Movements for Elderly Women - Approach to Clothing Ergonomics by Plaster Gypsum Experiments - (노년기 여성의 상지동작별 형태변화에 관한 연구 -석고법에 의한 피복인공공학적 접근-)

  • Min Hyun-Ja;Kim Hae-Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.2 s.30
    • /
    • pp.155-165
    • /
    • 1989
  • The purpose of this study was to investigate on the sleeve form variation according to arm movements for elderly women. This study was experimented using the Plaster gypsum. The subjects who were elderly women were divided into three groups according to Rorher Index. Arm movements were five type ($0^{\circ},\;45^{\circ},\;90^{\circ},\;135^{\circ},\;180^{\circ}$) to each the vertical motion in front and in side. The statistical analyses used in this study were Mean, Standard Deviation, Spearman's correlation coefficients, paired T-test, Kruskal-wallis one-way ANOVA and Duncan's multiple range test. The results were as follows: 1) Increasing the movements, the width of the sleeve increased and the height of the sleeve cap decreased but girth of the sleeve cap was not consistant. 2) When varied the rates of the three aspects of the sleeve, the height of the sleeve cap showed the largest variation rate. 3) There was a negative correlation between the height and the width of the sleeve. On the other hand, there was a positive correlation between the sleeve width and the sleeve girth. 4) There were the vertical motion differences between in front and in side on the three aspects of sleeve. 5) The sleeve width and the sleeve girth were different according to somatotypes but the height of the sleeve cap was not different. 6) According to the variation rates of the body surfaces in length of standard lines, the form of sleeve was changed more in the front than in the back. Maximum variation rate showed in the areas of $D_1-D_3,\;E_1-E_3$ in the horizontal lines and $A-E_2$ in vertical lines. 7) According to the comparative drawing of the heights of sleeve cap and sleeve girth, the sleeve basic pattern $S_1(A.H/4)$ was more suitable for the direction $0^{\circ}\;and\;45^{\circ}$. And the basic pattern S_6(A.H/5)$ was more suitable for the direction $90^{\circ}$, the pattern $S_7(A.H/6)$ suitable for the direction $135^{\circ}$, and the pattern $S_8(A.H/8)$ was more suitable for the direction $180^{\circ}$.

  • PDF

Interobserver variation in target volume for salvage radiotherapy in recurrent prostate cancer patients after radical prostatectomy using CT versus combined CT and MRI: a multicenter study (KROG 13-11)

  • Lee, Eonju;Park, Won;Ahn, Sung Hwan;Cho, Jae Ho;Kim, Jin Hee;Cho, Kwan Ho;Choi, Young Min;Kim, Jae-Sung;Kim, Jin Ho;Jang, Hong-Seok;Kim, Young-Seok;Nam, Taek-Keun
    • Radiation Oncology Journal
    • /
    • v.36 no.1
    • /
    • pp.11-16
    • /
    • 2018
  • Purpose: To investigate interobserver variation in target volume delineations for prostate cancer salvage radiotherapy using planning computed tomography (CT) versus combined planning CT and magnetic resonance imaging (MRI). Materials and Methods: Ten radiation oncologists independently delineated a target volume on the planning CT scans of five cases with different pathological status after radical prostatectomy. Two weeks later, this was repeated with the addition of planning MRI. The volumes obtained with CT only and combined CT and MRI were compared, and the effect of the addition of planning MRI on interobserver variability was assessed. Results: There were large differences in clinical target volume (CTV) delineated by each observer, regardless of the addition of planning MRI ($9.44-139.27cm^3$ in CT only and $7.77-122.83cm^3$ in CT plus MRI) and no significant differences in the mean and standard deviation of CTV. However, there were decreases in mean volume and standard deviation as a result of using the planning MRI. Conclusion: This study showed substantial interobserver variation in target volume delineation for salvage radiotherapy. The combination of planning MRI with CT tended to decrease the target volume and the variation.