• Title/Summary/Keyword: Standard time

Search Result 8,333, Processing Time 0.041 seconds

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

eLoran Signal Standard Inspection Process Development

  • Son, Pyo-Woong;Seo, Kiyeol;Fang, Tae Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.2
    • /
    • pp.153-158
    • /
    • 2021
  • In order to mitigate the vulnerability of the satellite navigation system against radio frequency interference, South Korea has been developing advanced terrestrial navigation system (eLoran) technology since 2016. The eLoran system synchronizes the transmission time of the pulse used in the existing Loran-C system with UTC and transmits correction information that can improve the position error. The eLoran system is known to reduce the position error of about 460 m of the existing Loran-C system to 20 m, and for this, the transmitter must be able to transmit eLoran signals according to more stringent standards. For this reason, an international standard that further developed the Loran-C signal standard established by US Coast Guard was established by Society of Automotive Engineers (SAE) International. In this paper, based on the analysis of the SAE9990 document, the international standard for eLoran transmission signals, a standard inspection process was produced to check whether the eLoran transmitter is transmitting signals in accordance with the standard.

Influence of the homogenizing grade and meathematical treatment on the determination of ground beef components with near infrared reflectance spectroscopy (식품의 근적외선 반사분광분석법에서 균질의 정도가 흡광도에 미치는 영향 및 수학적 처리방법에 관한 연구)

  • Oh, Eun-Kyong;Grossklaus, Dieter
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.408-413
    • /
    • 1992
  • This study was conducted to determine the effect of the homogenizing grade of sample on absorbance of near infrared reflectance spectrophotometer with which chemical compositions of food were rapidly and effectively analyzed. By the mathematical treatment of absorbance values standard error of prediction was reduced as follows. 1. The absorbance values of various samples ground for the same periods of time were calibrated before or after treatment with first or second derivative in an attempt to accurately predict the components of samples ground for the different periods of time. The standard error of prediction for moisture content were 1.478%, 0.658% and 0.580%, respectively, those for fat content 0.949%, 0.637% and 0.527%, respectively, and those for protein content 0.514%, 0.493% and 0.394%, respectively. Calibration of absorbance values after second derivative treatment showed the highest accuracy in predicting sample components. 2. The absorbance values of various samples ground for the different periods of time were calibrated before or after treatment with first or second derivative in order to accurately predict the components of samples ground for the different periods of time. The standard error of prediction for moisture content were 1.026%, 0.589% and 0.568%, respectively, and those for protein content 0.860%, 0.557% and 0.399%, respectively. The standard error of prediction were lower in the order of calibrations before and after first and second derivative treatments. As a result, calibration of absorbance values after second derivative treatment showed higher accuracy regardless of grinding time of samples.

  • PDF

Forecasting of building construction cost variation using BCCI and it's application (건축공사비지수를 이용한 건설물가 변동분석 및 공사비 실적자료 활용방안 연구)

  • Cho Hun Hee;Kang Kyung In;Kim Chang Duk;Cho moon Young
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.64-71
    • /
    • 2002
  • This research developed construction cost forecasting model using Building Construction Cost Index, time series analysis and Artificial Neural Networks. By this model, we could calculate the forecasted values of construction cost precisely and efficiently. And we also could find out that the standard deviation of forecasted values is 0.375 and it is a very exact result, so the standard deviation is just 0.33 percent of 112.28, the average of Building Construction Cost Index. And it show more exact forecasting result in comparison with Time Series Analysis.

  • PDF

Performance Evaluation of Switched Ethernet for Real-time Industrial Network

  • Kim, Tae-Jun;Lee, Kyung-Chang;Kim, Do-Hyung;Lee, Suk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.133.5-133
    • /
    • 2001
  • The real-time industrial network, often referred to as fieldbus, is an important element for building automated manufacturing systems. Thus, in order to satisfy the real time requirements of field devices such as sensors, actuators, and controllers, numerous standard organizations and vendors have developed various fieldbus protocols. As a result, IEC 61158 protocol including Profibus, WorldFIP, and Foundation Fieldbus is recently announced as an international standard. Many fieldbus protocols have an important advantage over the widely used protocols such as Ethernet (IEEE 802.3) in terms of the deterministic characteristics of the fieldbuses. However, the application of fieldbus has been limited due to the high cost of hardware and the difficulty in interfacing with multi-vendor products. In order to solve these problems, computer network ...

  • PDF

A Small-Area ISDB-T Time Deinterleaver Structure with Buffer Transformation (버퍼 변환을 이용한 저면적 ISDB-T 시간 디인터리버 구조)

  • Kang, Hyeong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.227-233
    • /
    • 2011
  • This paper presents a small-area ISDB-T time deinterleaver structure. ISDB-T is an mobile TV standard that is widely used in Japan and many South American countries. One of the strong points of the standard is the long interleaving depth, which enhance the communication performance. However, long interleaving requires many delay buffers, in other words many pointer registers. This paper reduces the number of pointer registers with the deinterleaver equivalent transformation. The experimental results show that the area is reduced with the proposed structure.

Improvement of Real-time Performance of ISO 11783 Network by Dynamic Priority Allocation Method (동적 우선순위 할당 기법을 이용한 ISO 11783 통신의 실시간성 향상)

  • Lee, Sang-Wha;Kim, Yoo-Sung;Lee, Seung-Gol;Park, Jae-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.794-799
    • /
    • 2012
  • The international standard, ISO-11783, was designed for the communication within an agriculture machinery. Even if it is based on the CAN (Control Area Network) protocol, its extended features which include point-to-point communication and large data transmission support show different network performance from the standard CAN. This paper proposes a dynamic priority allocation method to improve the real-time performance of ISO-11783. Computer simulation shows reduction of the deadline-missed cases and community latency via proposed algorithm.

Accelerated Life Test and Data Analysis of the Silver Through Hole Printed Wiring Board (가속수명시험을 이용한 은도통홀 인쇄회로기판의 신뢰성연구)

  • 전영호;권이장
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.2
    • /
    • pp.15-27
    • /
    • 1997
  • This paper describes a highly accelerated life test (HALT, USPCBT) method for rapid qualification testing of STH PWB(Silver Through Hole Printed Wiring Boards). This method was carried out to be an alternative to the present time-consuming standard 1344 hours life testing(THB). The accelerated life test conditions were $121^{\circ}C$/95%R.H. at 50V bias and without bias. Their results are compared with those observed in the standard 1344 hours life test at $40^{\circ}C$/95%R.H. at 50V bias and without bias. The studies were focused on the samples time-to-failure as well as the associated conduction and failure mechanisms. The abrupt drop of insulation resistance is due to the absorption of water vapour. And the continuous drop of insulation resistance is due to the Ag migration. The ratios of time-to-failure of HALT(USPCBT) to THB were 25 and 11 at 50V bias and without bias respectively.

  • PDF

TIME FRACTIONAL ADVECTION-DISPERSION EQUATION

  • Liu, F.;Anh, V.V.;Turner, I.;Zhuang, P.
    • Journal of applied mathematics & informatics
    • /
    • v.13 no.1_2
    • /
    • pp.233-245
    • /
    • 2003
  • A time fractional advection-dispersion equation is Obtained from the standard advection-dispersion equation by replacing the firstorder derivative in time by a fractional derivative in time of order ${\alpha}$(0 < ${\alpha}$ $\leq$ 1). Using variable transformation, Mellin and Laplace transforms, and properties of H-functions, we derive the complete solution of this time fractional advection-dispersion equation.

ESD(Exponential Standard Deviation) Band centered at Exponential Moving Average (지수이동평균을 중심으로 하는 ESD밴드)

  • Lee, Jungyoun;Hwang, Sunmyung
    • Journal of Intelligence and Information Systems
    • /
    • v.22 no.2
    • /
    • pp.115-125
    • /
    • 2016
  • The Bollinger Band indicating the current price position in the recent price action range is obtained by adding/substracting the simple standard deviation (SSD) to/from the simple moving average (SMA). In this paper, we first compare the characteristics of the SMA and the exponential moving average (EMA) in the operator's point of view. A basic equation is obtained between the interval length N of the SMA operator and the weighting factor ${\rho}$ of the EMA operator, that makes the centers of the 1st order momentums of each operator impulse respoinse identical. For equivalent N and ${\rho}$, frequency response examples are obtained and compared by using the discrete time Fourier transform. Based on observation that the SMA operator reacts more excessively than the EMA operator, we propose a novel exponential standard deviation (ESD) band centered at the EMA and derive an auto recursive formula for the proposed ESD band. Practical examples for the ESD band show that it has a smoother bound on the price action range than the Bollinger Band. Comparisons are also made for the gap corrected chart to show the advantageous feature of the ESD band even in the case of gap occurrence. Trading techniques developed for the Bollinger Band can be straight forwardly applied to those for the ESD band.