• 제목/요약/키워드: Standard test method

검색결과 2,902건 처리시간 0.035초

Scene Change Detection using the Automated Threshold Estimation Algorithm

  • Ko Kyong-Cheol;Rhee Yang-Won
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제14권3호
    • /
    • pp.117-122
    • /
    • 2005
  • This paper presents a method for detecting scene changes in video sequences, in which the $chi^{2}$-test is modified by imposing weights according to NTSC standard. To automatically determine threshold values for scene change detection, the proposed method utilizes the frame differences that are obtained by the weighted $chi^{2}$-test. In the first step, the mean and the standard deviation of the difference values are calculated, and then, we subtract the mean difference value from each difference value. In the next step, the same process is performed on the remained difference values, mean-subtracted frame differences, until the stopping criterion is satisfied. Finally, the threshold value for scene change detection is determined by the proposed automatic threshold estimation algorithm. The proposed method is tested on various video sources and, in the experimental results, it is shown that the proposed method is reliably estimates the thresholds and detects scene changes.

  • PDF

왕수분해와 결합한 자동분석법의 토양 중 불소시험 유효성 연구 (The Validation Study of Auto Anlysis Method Combined with Aqua Regia Digestion for Fluorine of Soil)

  • 나경호;윤인철;이정복
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권5호
    • /
    • pp.8-15
    • /
    • 2010
  • The purpose of this research is to check the validation of an auto-analysis method combined with aqua regia digestion apparatus for improvement of water distillation method used as a fluorine test of soil. Fluorine contents of CaO used in the pretreatment course of water distillation method were 120 mg/kg ~ 5,064 mg/kg at the blank test, which was exceeded up to maximum 12.5 times of the soil standard, so it was estimated due to a effect of fluorine existing as impurities of CaO. The recovery test of the same samples indicated that water distillation method and auto-analysis method were 134.5mg/kg and 161.7mg/kg respectively, the recovery ratio of the latter was 16.8% higher than the formal. The validation test of two methods satisfied the standard, but auto analysis method was excellent more than distillation method. Also, auto analysis method could save a analysis time up to maximum 4.7 times by comparison with water distillation method.

An Empirical Evaluation of Test Data Generation Techniques

  • Han, Seung-Hee;Kwon, Yong-Rae
    • Journal of Computing Science and Engineering
    • /
    • 제2권3호
    • /
    • pp.274-300
    • /
    • 2008
  • Software testing cost can be reduced if the process of testing is automated. However, the test data generation task is still performed mostly by hand although numerous theoretical works have been proposed to automate the process of generating test data and even commercial test data generators appeared on the market. Despite prolific research reports, few attempts have been made to evaluate and characterize those techniques. Therefore, a lot of works have been proposed to automate the process of generating test data. However, there is no overall evaluation and comparison of these techniques. Evaluation and comparison of existing techniques are useful for choosing appropriate approaches for particular applications, and also provide insights into the strengths and weaknesses of current methods. This paper conducts experiments on four representative test data generation techniques and discusses the experimental results. The results of the experiments show that the genetic algorithm (GA)-based test data generation performs the best. However, there are still some weaknesses in the GA-based method. Therefore, we modify the standard GA-based method to cope with these weaknesses. The experiments are carried out to compare the standard GA-based method and two modified versions of the GA-based method.

EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법 (An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film)

  • 허정;이원희
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.79-83
    • /
    • 2018
  • EMI 스프레이 코팅막의 차폐효과(Shield Effectiveness, SE)를 측정하기 위한 정확한 방법을 제안하였다. 고주파 시뮬레이션을 한 후에 원형 동축 표준 측정기를 제작하였다. 원형 동축 표준 측정기에 삽입하기 위하여 EMI 스프레이 코팅막의 시료를 가공하였다. 차폐효과 측정을 위한 측정기는 에이질런트 8722ES 벡터 네트워크 분석기를 이용하였다. 이러한 측정기와 측정시료의 구성으로 구리와 은의 혼합 스프레이 코팅 시료의 정확한 차폐효과를 측정하였다. 동박 시료의 차폐효과는 70 dB로 측정되었고, 구리와 은의 혼합 스프레이 코팅 시료의 차폐효과는 60 dB로 측정되었다. 이와 같은 측정 결과로 원형 동축 표준 측정기의 신뢰성을 확인하였다.

Studies on the evaluation of efficacy of functional cosmetics (I) -Studies on the in vitro SPF test method of sunscreen products

  • Son, Kyung-Hun;Kim, Young-Ok;Lee, Jeong-Pyo;Yang, Seong-Jun;Paek, Ock-Jin;Kim, Won-Hee;Kim, Chong-Kap;Heo, Moon-Young;Choi, Sang-Sook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.404.2-404.2
    • /
    • 2002
  • The present study was undertaken to develop the in vitro sun protection factor(SPF) test method having good correlation with in vivo method using human. 8% homomentyl salicylate. P3 reference standard and commercially available sunscreen products were measured by the in vitro method using SPF 290S analyzer. and the SPFs were compared with the SPFs measured by in vivo test method. In vitro SPFs of 8% HMS and P3 reference standard were 4.59$\pm$0.12 and 14.94$\pm$0.83. (omitted)

  • PDF

유한요소 해석을 이용한 3상 유도전동기의 효율 불확도 평가 (Evaluation of Efficiency Uncertainty for Three-phase Induction Motor using Finite Element Analysis)

  • 이호현;박한석;전희득;우경일
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.163-168
    • /
    • 2017
  • This paper presented an evaluation method for the efficiency uncertainty of a three-phase induction motor using finite element analysis. The motor efficiency in the finite element analysis is calculated by the loss separation method as in the actual test. In the process of evaluating the efficiency uncertainty, the difference between the finite element analysis and the actual test is the method of calculating the type-A / B standard uncertainty of the input quantity to estimate the efficiency and each losses. For the input quantities which can confirm the instantaneous values with respect to time, the type-A standard uncertainty in the finite element analysis is calculated from the RMS values or average values having separate periods in the steady state. And, the type-B standard uncertainty in the finite element analysis is assumed to be zero. Also, this paper compared and analyzed the efficiency uncertainty evaluated by the proposed method and the efficiency uncertainty through the actual test.

GIS를 이용한 대규모 매립지반의 액상화발생가능성 평가 (Assessment of Potential for Liquefaction in the Large Reclamation Site Using GIS)

  • 김홍택;유시동;박사원;이형규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1512-1519
    • /
    • 2005
  • In this study, the potential for liquefaction in the Incheon international airport was calculated by appling the standard penetration test data and laboratory test data to the modified Seed & Idriss(2001) method. The analysis was performed on the non-plastic silty layer and silty sand layer which within the depth of 20m, below 20 of the standard penetration value(N), and the ground water level. Also, each set of data was mapped by using GIS(geographic information systems) and the factor of safety for the potential for liquefaction was obtained by overlapping those layers. As a result, it was found that there exist potential hazard zone for the liquefaction partially. So, the additional detailed assessments for those are thought to be necessary.

  • PDF

국내 전기방식용 정류기의 성능평가 시험 방법에 대한 표준화 연구 (A Study on the Standardization of Performance Test Method for CP Rectifier in Korea)

  • 배정효;하태현;이현구;김대경;이지인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.253-256
    • /
    • 2002
  • Generally, the owners of the facilities adopt CP(Cathodic Protection) Systems to protect the corrosion accidents previously. The developed countries have secured the standard of CP systems through the various researches and consolidation of the rules. So in the first stage. I had been studied the international standards; JSCE, NACE Standard, ASTM, DNV, Australian Standard etc. and standardized the CP systems about items performance. specifications and so on. In this thesis, I have been studying the results of standardization of performance test methods of CP rectifier to apply in Korea.

  • PDF

아포살균용 살균소독제 유효성 평가방법 확립 (Establishing Test Method of Sporicidal activity of Commercial Sterilants)

  • 김형일;전대훈;윤혜정;곽인신;엄미옥;성준현;박나영;원선아;배서영;이영자;김소희
    • 한국식품위생안전성학회지
    • /
    • 제24권4호
    • /
    • pp.312-317
    • /
    • 2009
  • 세균포자는 살균소독제에 대해 영양세포보다 수백~수천배이상 저항성을 가지고 있기 때문에 과산화수소 및 과산화초산을 원료로 하는 아포살균용 살균소독제는 Escherichia coli 및 Staphylococcus aureus의 감소율을 측정하는 현행 살균소독제 유효성 평가방법을 적용하기 어렵다. 따라서, 아포살균용 살균속독제의 유효성 평가를 위해 Bacillus subtilis ATCC 6633 포자를 표준균주로 하여 아포살균용 살균소독제를 처리했을 때 초기포자수를 $10^3$이상 감소시키는지를 측정하는 정량적 표준시험방법을 확립하였다. 확립된 시험법은 아포살균력을 측정하는 국가표준시험법으로서 아포살균용 살균소독제의 유효성 평가에 적합하였다.

국내 전기방식 시스템 및 시험 방법에 대한 표준화 연구 (A Study on the Standardization for Cathodic Protection System and its Testing Method in Korea)

  • 배정효;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.663-665
    • /
    • 2001
  • Generally, the owners of the facilities adopt CP(Cathodic Protection) Systems to protect the corrosion accidents previously. The developed countries have secured the standard of CP systems and its test methods through the various researches and consolidation of the rules. So, we have been studying the international standards; JSEC, NACE Standard, ASTM, DNV, Australian Standard etc. and standardizing the systems and its test methods to apply in Korea.

  • PDF