• Title/Summary/Keyword: Standard test method

Search Result 2,912, Processing Time 0.031 seconds

Effectiveness of the Project Approach Method in the Scientific Problem Solving Ability of Children (프로젝트 접근법이 유아의 과학적 문제 해결력에 미치는 영향)

  • Chae, Soon Hee;Lee, Gi Hyoun
    • Korean Journal of Child Studies
    • /
    • v.23 no.6
    • /
    • pp.103-119
    • /
    • 2002
  • In this investigation of the effectiveness of the Project Approach Method the 32 4-to 5-year-old subjects (16 each in the experimental and comparative groups) were pre-tested before the Project Approach Method was applied (23 times over 7 weeks) in the experimental group while the comparative group had science activities using standard unit methods of instruction. Then, all the children had a posr-test. Data were analyzed by t-test and ANCOVA. Results showed differences between the experimental group and the comparative group in their scientific problem solving ability. Specifically, effects were found on 14 sub-factors, but no difference were found on 3 sub-factors.

  • PDF

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-seop;Lee, Keun-hee;Kim, Sun-woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.393.1-393
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so far. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

Reduction Effect of liquefaction by Vibro-Replacement Stone Columns (진동치환 스톤칼럼공법에 의한 액상화 저감 효과)

  • Lee, Song;Chae, Jum-Sik;Park, Sang-Kuk
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.443-450
    • /
    • 2001
  • This paper shows the reduction effect of tile earthquake-induced liquefaction potential of soils that improved by Vibro-Replacement Stone Columns. The Vibro-Replacement Stone Columns method transforms soft cohesive soils into a composite mass of compacted granular or crushed stone columns by using vibrating equipment and water jets. This study investigated and analyzed the behavior of the stone columns and composite ground using the results of in situ test and measurement at the job-site. This paper shows the evaluation of the earthquake-induced liquefaction potential of soils using in situ test. There are different types of in situ test used in the evaluation the liquefaction potential. In the particular study the Standard penetration test, and Cone penetration test were used. The N value of Standard Penetration test has been used all over for a very long time. The evaluation of the liquefaction of soil was performed using the worldwide renewed Cone penetration test

  • PDF

A Study on Daily Temperature Cycle of Environmental Test in the Korean Peninsula (한반도 지역의 환경시험 온도 일주기 연구)

  • Lee, Jeong-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.62-70
    • /
    • 2007
  • Most design temperature of environmental test in korea is based on the standard of Department of Defense. There are few studies to establish temperature standard. Besides the representative environmental test guide 'MIL-STD-810F' encourage to tailor to generate the most relevant test data possible and to test to make a match of test environment with operational environment. Under these circumstances, it is irrational to comply with baseless daily cycle. Thus the study about design method of test temperature is essential. So, the daily cycles to be appropriate to the Korean peninsula was presented in this study. And this research shows how to derive two main element, frequency-of-occurrence and daily maximum (minimum) temperature in daily cycles, in case we can not find the daily cycle.

Antenna Gain Measurement in Time Domain (시간 영역에서 안테나 이득 측정 연구)

  • Park, Jungkuy;Kim, Woo-Nyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1217-1227
    • /
    • 2012
  • There are several antenna calibration methods, so-called 3-Antenna Method, Standard Site Method, and Standard Antenna Method which measure the antenna gains or antenna factors. These methods yield the free space or quasi free space antenna gains in only the frequency domain. In this paper, an antenna calibration method using the time domain in the open area test site is discussed. The reflected waves due to the ground are traced in the time domain. After they are removed by the time gating function of network analyzer, the free space transmission coefficient $S_{21}$ is extracted. Such a way is applied to the broad band horn antenna ranging 1 GHz to 18 GHz, and the free space gains are obtained by Friis transmission equation. The method is checked by Standard Site Method in open area test site. The results show comparatively good agreement except for 18 GHz.

The effect of short and long duration sintering method on microstructure and flexural strength of zirconia (단시간과 장시간의 소결방법에 따른 지르코니아의 굴곡 강도와 미세구조의 변화)

  • Lee, Ha-Bin;Lee, Tae-Hee;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.73-79
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the influence of short and long duration sintering on microstructure and flexural strength of zirconia. Methods: To conduct three-point bending test, Zirconia specimens are milled according to ISO 6872 guidelines(N=18, n=9 per group). Two specimens group(n=8) is sintered for 10 hours(Standard schedule) and 3 hours(Speed schedule) at the peak temperature of 1550℃ with silicon carbide sintering furnace. Flexural strength of specimens are measured by instron. After coating each specimen(n=1), microstructure of specimens is observed using Scanning Electron Microscope(SEM). T-test was utilized to statistically assess the data. Results: The mean and standard deviation value of the flexural strength for standard schedule group are 578.15±57.48Mpa, that of speed schedule are 465.9±62.34Mpa. T-test showed significant differences in flexural strength between two zirconia specimen group which applied standard schedule and speed schedule respectively(p<0.05). Conclusion: The result of this study showed that the increase in sintering time led to increased grain size, and also to a positive effect on the flexural strength.

Evaluation of Domestic CCPs(Coal Combustion Products) Quality by API Test Method (API시험법에 의한 국내 석탄회의 품질 평가)

  • Yoo, Sung-Won;Yu, Kyung-Geun;Cho, Young-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • Recently, recycling of industrial by-products and CO2 reduction have been important issues in the world. In this reason, applications and reuse of Fly ash as a binder for concrete, which is generated in thermoelectric power plant, have been one of the effective recycle methods. In order for Fly ash to be applied to concrete, Korean Standard(KS) has selected and managed quality such as $SiO_2$, fineness, specific gravity, ignition loss and activity index. However, there is a limits for activity index, whose test period required is at least 28 days or 91 days. Activity index is the critical indication standard to determine mechanical strength of concrete that contained Fly ash. To complement the disadvantage of test method, this research provided "API test method", which quickly measure Pozzolanic reaction of Fly ash can be considered as a alternative of activity index. Then, the adaptable API test method need to be investigated through comparative analysis with the test result of API, activity index and K-value. The test method can make evaluation of Fly ash quality faster and more accurate. As a result, most Fly ash produced in Korea has not been satisfied in the KS quality standard except water content and specific gravity, and especially fluidized bed boiler ash has its characteristics. Also, API, activity index and K-value have superior interrelationship. The interrelationship between API and activity index and K-value gets increased as the material age gets higher, so API test can be considered as very useful test method for Pozzolanic reaction evaluation of Fly ash.

Waterproof Characteristic for Environmental Water Flows in Small Streams (소규모 하천 친환경 물흐름을 위한 차수특성)

  • Park, Min-Cheol;Kim, Seong-Goo;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.192-199
    • /
    • 2010
  • This research produced internal model tester ($2.0m{\times}2.0m{\times}1.0m$) to evaluate the field application of Paju Unjeong District water recycling system for small streams eco-friendly river bed disparity method for the first time in Korea and conducted comparative analysis of the Paju Unjeong District water recycling system field test results and infiltration rate result of internal tests by each rainfall intensity following surface material. Infiltration rate result of internal tests concrete pavement by rainfall intensity following surface material, asphalt pavement, bentonite mate, stabilized soil construction and mixed soil construction manifested low infiltration rate. On the contrary, compaction soil, grassland and water permeable packaging materials resulted in significant amount of infiltration rate. As for the field permeability test results, they were manifested similar tendency as indoor permeability test results and they satisfied the standard for standard of water permeability of domestic disparity facility (less than $1.0{\times}10-7cm$/sec). As compaction rate increased, unconfined compression strength increased as well while coefficient of water permeability decreased.

  • PDF

Comparative Study on Test Method of Compressive and Flexural Characteristics of Structural Adhesives for FRP Composites used in Strengthening RC Members (구조보강용 FRP 함침.접착수지의 압축.휨 특성치 시험방법 비교 연구)

  • You, Young-Chan;Choi, Ki-Sun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.349-352
    • /
    • 2006
  • Pull-off test is generally used as a method of evaluating bond strength of FRP with concrete at the job site. However, pull-off test damages FRP composites and the maximum pull-off strength is limited up to tensile strength of concrete. Accordingly, it is required to set-up a test method that can simply evaluate bond performance of structural adhesive. This study suggested compression and bending test of epoxy resin as test methods that can indirectly evaluate performance of adhesive, as well as standardized test specification for different types of specifications from various countries. In this study, the section dimension of compression and bending test specimens is unified, and standard test specimen size is achieved by test results.

  • PDF

Comparative Study on Cupping Apparatuses for Medical Use by Mechanical Stability and Functional Test (수동식 부항기의 기계적 안정성과 성능의 실험적 비교연구)

  • Soh, Mun-Gie;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2008
  • Objectives : It is sure that standardization of medical instruments is very important and necessary. Cupping therapy is one of the traditional oriental medical method, and it is necessary to set up a standard of cupping therapy and instruments. Methods : We select 3 major cupping instrument makers according to a questionnaire survey of 2001 oriental medical doctors. Dae Gun is A maker, Han Sol is B maker, Dong Bang is C maker. And with these air pumps we make experiments on stability by an inner impact test and a falling test. With these cups we check stability by an inner impact test and a disinfection test. And to know function of these instruments we test a negative pressure and maintain attached cups until 5 to 10minutes. Results : All results of experiments(impacted test, disinfection test, falling test) on stability of cups and air pumps are suitable for medical instrument. And the efficiency of 3 major makers shows various results. Negative pressure of B group is the highest, C group is the second, A group is the lowest. Pressure maintenance test shows A and C group is comparatively up to the experimental standard(<10%), B group is comparatively below the experimental standard(<10%). Conclusions : Results show stability of cups and air pumps is suitable for medical instruments. And negative pressure of cupping and maintenance of pressure show various results. So it is necessary to set up a standard negative pressure of cupping and maintenance of pressure.