• 제목/요약/키워드: Standard of installation

검색결과 766건 처리시간 0.047초

실내공간에서의 인공조면 균제도 산출방법에 대한 일고찰 (A Study of yield method including artificial lighting uniformity ration in interior space)

  • 김현지;;안옥희
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.139-139
    • /
    • 1999
  • In this paper, the result of study in artificial lighting uniformity ratio yield method subject to lecture room are reported. It is desirable that the application of equation ① U=Ei/Ex×100 cannot be used to the mean value in place to be effective of light and darkness. And it is desirable that the application of equation ② U=Ei/Ea×100 or equation ③ U=(Ea-Ei)/Ea×100 be used to the mean Value equality illumination conditions. Also, requiring preparation of judgement standard, uniformity ratio equation agree with actual circumstances in this country. It must be considered intensity of illumination and specificity of space in established standard.

SKY 72골프클럽 야간조명시설 공사 (Night lighting design of Sky 72GC)

  • 기유경;이원서;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.79-84
    • /
    • 2007
  • Recently, there are rapid increases in golf population. People are enjoying play golf not only during the day but also at night as well. Although there are not many golf courses that offer night play, people inquire place where they can play night games due to their busy daily lives. To supply the demand in national golf courses night-lighting has been pushed ahead competitively, however there are few standards of lighting design in golf course. Because it is not clear that the standards of lighting in the world yet, this study aimed at presentation of standard of lighting design for planning golf course. Investigating the cases of golf course, this study suggested illumination standard of golf course to support comfortable visual-environment and measures to prevention glare for visitors.

  • PDF

표준화된 인체모델을 이용한 공진형 무선전력전송 시스템의 효율 변화 및 인체 안전성 분석 (Efficiency and EMF Safety Analysis of Wireless Power Transfer System Using Standard Human Model)

  • 신한수;변진규
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.96-103
    • /
    • 2013
  • In this paper, resonant wireless power transfer systems are designed with double loop resonant coils for the resonant frequency of 150kHz. The transfer efficiency characteristics is analyzed according to the coil size, and the distance and misalignment between the coils. Then the change in efficiency is investigated when a human model is located between the resonant coils using the homogeneous human phantom of IEC-62311 standard. Also, in order to assess the safety of the wireless power transfer system, the induced current density inside the human model is calculated when it is exposed to the magnetic field of a plane wave and resonant coil. Then, the results are compared with the exposure limits in the EMF (electromagnetic field) safety guidelines.

저압 지중케이블의 토양 열저항률 적용에 관한 연구 (A Study on the Apply to Soil Thermal Resistivity of Low-Voltage Underground Power Cables)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.65-70
    • /
    • 2012
  • The current-carrying capacities in IEC standards for underground refers to a soil thermal resistivity of 2.5[$K{\cdot}m/W$] where no measured data are available. But this value is considered too conservative and may not justifiable economically as to need precaution in using the value. In this paper, the standard practices on the application of soil thermal resistivity of some countries(UK, USA etc) are surveyed and proposed a reasonable representative value 1.0[$K{\cdot}m/W$] of soil thermal resistivity considering the domestic soil thermal properties with regard to the application of IEC standard.

산업용전력사용고객의 최대전력 예측에 의한 변압기용량 산정에 관한 연구 (Recommended Practice for the Assessment of Transformer Capacity by the Forecasting of Peak Power in Industrial Customers)

  • 김세동;신화영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2009
  • Contract power conversion factor which is applied to estimate contract power of industrial customers is an important standard to calculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for industrial customers as to AMR system. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum. minimum and thus it was carried the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60%.

  • PDF

사무소용빌딩의 최대전력 예측에 의한 변압기용량 산정에 관한 연구 (Recommended Practice for the Assessment of Transformer Capacity by the Forecasting of Peak Power in Office Building Customers)

  • 김세동;유상봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 2008
  • Contract power conversion factor which is applied to estimate contract power of general customers IS an important standard to caculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 132 office building customers as to AMR system. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60%.

  • PDF

방송 공동수신설비의 설치기준 (Regulation of Common Reception System for Broadcasting Signal)

  • 허영태;김광의;권원현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.183-184
    • /
    • 2008
  • From the beginning of a new millennium, the digital broadcasting services had been adopted to cable, satellite and radio broadcasting services as well as the terrestrial TV broadcasting services. The government established the installation standard of digital receiving equipment in 2007, which is needed for taking the new digital broadcasting services without additional facilities in an apartment house. In this paper, I will show the installation standard of digital receiving equipment in an apartment house and give a detailed explanation for the main criteria of it.

  • PDF

전광선속 표준전구 개발 (Development of Total-Luminous-Flux Standard Lamps)

  • 서정철;김용완;정용붕
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.1-6
    • /
    • 2001
  • 조명업체에서 적분구를 이용한 광원의 전광선속을 측정하는데 기준광원으로 활용하기 위하여 신뢰성 높은 전광선속 표준전구를 개발하였다. 전광선속 표준전구는 공간세기분포가 균일하도록 되어 있으며, 사용시간 100[h]동안에 전광선속 변화율이 0.5% 이내로 양호한 안정도를 갖는다.

  • PDF

손실감도를 이용한 계통손실 최적화에 대하여 (On The Optimal Generation Using The Loss Sensitivities Derived by Angle Reference Transposition)

  • 양성덕;이상중
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.59-63
    • /
    • 2005
  • 전력계통을 효율적으로 운용하려면 관련량을 정확하고 신속히 계산하는 좋은 알고리즘이 필요하다. 최근 IEEE Transaction on Power System에 위상각 이동을 이용한 손실 최적화 알고리즘이 발표되었다. 동일한 손실최적화 문제를 본 논문에서는 Standard method of Lagrange Multiplier 기법을 적용하여 해석하였으며, 그 결과 저자들은 두 가지 방법이 수학적으로 동일함을 증명하였다.

PLC 제어 시스템의 신뢰도 향상에 관한 연구 (A Study on the Enhancement of Reliability for PLC Control System)

  • 이석용;이홍규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.267-272
    • /
    • 1999
  • In many fields of automation, increasingly high demands are being placed on the availability and fault tolerance of programmable logic controller(PLC). Particularly in fields where a plant shutdown would be extremely expensive. In such cases, only redundant systems can offer the standard of availability required. The redundant configurations contain more then would normally be necessary for the relevant function. Fault tolerant systems will normally continue to operate even if one or more faults cause parts of the control system to fail.

  • PDF