• Title/Summary/Keyword: Standard of disaster management

Search Result 215, Processing Time 0.029 seconds

Analysis of Fulfillment Status on Environment·Landscape Damage Reduction and Disaster Prevention in Quarry Related to Mountainous Districts Management Act (산지관리법에 명시된 토석채취지의 환경·경관피해 및 재해저감 관련 법 조항의 이행실태 분석)

  • Park, Jae-Hyeon;Kim, Ki-Dae;Bae, O-Jang
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.2
    • /
    • pp.196-203
    • /
    • 2017
  • Quarrying industry is typical industry that troubled between the market and government regulations in the forestry. Especially, it is difficult to consider aspects of economics and environment, landscape, disaster at the same time. Therefore, Quarrying industry need revised statutes according to regulatory reform and mitigation. This study conducted to provide basic data for regulatory reform and mitigation in quarrying industry. We surveyed 22 article of mountainous districts management act and lower statutes to employers and business interests on quarry 55 places in the Republic of Korea. As a result, fulfillment status of environmental damage reduction and disaster prevention were satisfactory. But fulfillment status of landscape damage reduction were not applicable. This result is due to the social mood that emphasizes the forest landscape. But there is need to improve the efficiency of grit chamber through present standard on effluent(water pollution prevention). In conclusion, policies should be established for realistic regulation and developed industry to quarrying industry.

Temporal and Spatial Distribution of Particulate Carcinogens and Mutagens in Bangkok, Thailand

  • Pongpiachan, Siwatt;Choochuay, C.;Hattayanone, M.;Kositanont, C.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1879-1887
    • /
    • 2013
  • To investigate the level of genotoxicity over Bangkok atmosphere, $PM_{10}$ samples were collected at the Klongchan Housing Authority (KHA), Nonsree High School (NHS), Watsing High School (WHS), Electricity Generating Authority of Thailand (EGAT), Chokchai 4 Police Station (CPS), Dindaeng Housing Authority (DHA) and Badindecha High School (BHS). For all monitoring stations, each sample covered a period of 24 hours taken at a normal weekday every month from January-December 2006 forming a database of 84 individual air samples (i.e. $12{\times}7=84$). Atmospheric concentrations of low molecular weight PAHs (i.e. phenanthrene, anthracene, pyrene and fluoranthene) were measured in $PM_{10}$ at seven observatory sites operated by the pollution control department of Thailand (PCD). The mutagenicity of extracts of the samples was compared in Salmonella according to standard Ames test method. The dependence of the effects on sampling time and on sampling location was investigated with the aid of a calculation of mutagenic index (MI). This MI was used to estimate the increase in mutagenicity above background levels (i.e. negative control) at the seven monitoring sites in urban area of Bangkok due to anthropogenic emissions within that area. Applications of the AMES method showed that the average MI of $PM_{10}$ collected at all sampling sites were $1.37{\pm}0.10$ (TA98; +S9), $1.24{\pm}0.08$ (TA98; -S9), $1.45{\pm}0.10$ (TA100; +S9) and $1.30{\pm}0.09$ (TA100; -S9) with relatively less variations. Analytical results reconfirm that the particulate PAH concentrations measured at PCD air quality monitoring stations are moderately low in comparison with previous results observed in other countries. In addition, the concept of incremental lifetime particulate matter exposure (ILPE) was employed to investigate the potential risks of exposure to particulate PAHs in Bangkok atmosphere.

Characteristics and Policy Implications of Private Development Parks in Japan (일본 민설공원 제도의 특성과 시사점)

  • Kim, Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.1
    • /
    • pp.119-128
    • /
    • 2016
  • Urban park planning has become difficult due to the lack of municipal funds. Thereupon, a special scheme was imposed for city park planning. Since then, a legal amendment was made for economical improvement and more active participation. However, there are a lot of questions about whether it was a suitable direction for parks and where it should be emphasized for public interest. Base on these concerns, this study examined the basis and characteristics of location, creation, and maintenance of private development parks in Japan, which was the policy model of Korean private parks. Location and space planning of private development parks was made up considering an effective green network and disaster prevention function, and a minimum area was about 1.42ha. The minimum area, 1ha, was established on the basis of considering realistic possibilities, disaster protection, and universal validity. It was also amended to consider the standard of type two mid- to high-rise exclusive residential areas and consultation with regional governance. Finally, it was built on the lowest limit of ordinance of the relevant city; for example, 100% of the floor area ratio, 30% of the building coverage ratio, and the maximum height of 11 stories, etc. For maintenance, private and public sectors were working together. Maintenance fees for 35 years (based on $300yen/m^2$ per month) were paid en bloc by the licensee. However, the city was paid for facilities that accompanied excessive maintenance costs. Meanwhile, it seemed difficult to introduce attractive profit facilities because of the limitations in location, usage permission, and introduction equipment; furthermore, there were problems with management authority, and the burden of expenses was deducted. For creating private Korean parks, this study suggested that we should build priority of creating city parks and select appropriate locations first; also, we need to make criteria for location, creation, and standard management rules that are relevant to the whole nation of Korea.

A Study on the Self-Prevention Plan System (자체방제계획서 검토기준 마련 연구)

  • Kim, Sungbum;Noh, Hyeran;Lee, Jinseon;Kim, Jungmin;Ahn, Seungyoung;Seok, Kwangseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • Self-Prevention Plan Review Report and Review Standards Process Safety Management(PSM), Safety Management System(SMS), including the contents of the safety management system audit standards, notices and guidelines on the screening form and were analyzed. Were expected through the interview and screening personnel in the screening process to identify problems prior research so that it can be reflected in the. Also divided into methods such as document review and on-site implementation status of the review written Emergency Preparedness Plan depending on the item proposed. Toxic Chemicals Control Act(TCCA) Self-Prevention Plan Review Regulations. However, the substantial approval process, and do not enable the system performance lacked Self-Prevention Plan Review. Review half configuration to enhance the professionalism and efficiency of the work of this research was performed.

A Study on Civil Defense Evacuation Facilities (전국의 대피시설 실태조사를 통한 민방위 대피시설 표준 정립 모델 구축 연구)

  • Park, Namhee;Yeo, Wookhyun;Kim, Taewhan
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.56-70
    • /
    • 2012
  • Civil defense evacuation facilities currently installed in our country are necessary to survey the operating status. The purpose of this study is to survey on the current facility for civil defense evacuation facilities equipment, management, and problem analysis, research and to build a facility model of the standard formulation through the analysis on the actual condition of the civil defense evacuation facility. The conclusions of this study are as follows. First, the civil defense evacuation facilities are most in Seoul. Second, civil defense evacuation facilities proved to be checked periodically without a systematic management. Many facilities do not have communication facilities appear to be evacuated in an emergency situation is expected to have difficulty in contact with the outside world. Fourth, the old civil defense evacuation facilities are in the center of the metropolitan area.

Development of automatic alert populating system of earth structures based on sensor monitoring (센서 모니터링을 활용한 토류구조물 상황전파 자동화 시스템 개발)

  • Kim, Yong-Su;Ahan, Sang-Ro;Jung, Jae-Hyun;Han, Sang-Jea;Jung, Seung-Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.667-672
    • /
    • 2009
  • Gathering information and systemization of infrastructure disaster management is to reduce uncertainties in making decisions and maximize the number of alternations. The key objects of a sensor-based progress report and propagation automation systems are to provide objective data, realize and support decision making and deliver them to a certain area, department, manager and other people rapidly. The major findings and results of this study are as follows. 1) Application of international standard-based alerting protocol(CAP; Common Alerting Protocol). 2) Development of database of existing progress report and propagation manual in order to achieve networking of safety management on major social infrastructure of the nation. 3) Development middleware application programs to progress report and propagation data using SMS, FAX, EMS, VMS, MMS.

  • PDF

The Necessity and Method of Stand Density Control Considering the Shape Ratio of Pinus thunbergii Coastal Disaster Prevention Forests in South Korea (곰솔 해안방재림의 형상비를 고려한 밀도 관리의 필요성과 방안)

  • Kim, Suk-Woo;Chun, Kun-Woo;Park, Ki-Hyung;Lim, Young-Hyup;Yun, Ju-Ung;Kwon, Se-Myoung;Youn, Ho-Joong;Lee, Jin-Ho;Teramoto, Yukiyoshi;Ezaki, Tsugio
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.3
    • /
    • pp.411-420
    • /
    • 2015
  • This study examined methods for stand density control by using shape ratio (tree height/DBH) and its application for effective management of Pinus thunbergii coastal disaster prevention forests. We analyzed the present conditions (height, DBH, and density) of P. thunbergii coastal disaster prevention forests at 123 study sites on Jeju Island and west, south, and east coasts of South Korea and compared them with results from previous studies. The average shape ratio for P. thunbergii showed positive correlations with stand density and was significantly higher on the west coast (66.32) than on the south (49.57) and east (48.19) coasts and Jeju Island (48.29). Stands with shape ratio higher than 70 accounted for 50% of the total study sites on the west coast, indicating a decrease in their disaster prevention function compared to that of other previous studies. The stand density in most coastal areas, except the east coast, was significantly higher than the standards recommended by the Korea Forest Service and the Forestry and Forest Products Research Institute of Japan, indicating the need for stand density control. According to the growth estimation equation for P. thunbergii in the coastal area of South Korea, density control is required for young stands less than 14 years old, which show drastic increase in the shape ratio, to conserve their disaster prevention function. Particularly, the first thinning of P. thunbergii forests should be implemented before the stand age of 8 years that a shape ratio exceeds 70. For disaster-prone young stands (${\leq}20cm$ DBH) of P. thunbergii, the stand density was higher in the standard of Japan considering shape ratio than in that of Korea aiming timber production. Hence, the standard guidelines employed in Japan, which assign higher importance to disaster prevention function based on field surveys, can be applied effectively for controlling the stand density of P. thunbergii coastal forests in South Korea, to improve their disaster prevention function.

A Case Study on Application and Standardization of Safety Adminstration Model in Complex Style Multiflex Housing Business. (단지형 다세대주택신축사업의 안전경영모델 표준화 및 적용사례 연구)

  • Kim, Sung Soo;Yoo, Tae Gyeong;Yoo, Jin Yeol;Lee, Tae Sik
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.43-52
    • /
    • 2016
  • Notwithstanding industrial accident decrease generally, Construction industry is on the rise recently. Most accident occurs in the small scale like as multiflex housing, remodeling, neighbourhood facility more than safety supervisor appointed large scale construction site. By the size of business place, 81.6% of total accident occurs mostly in small scale site that is bellow 120 billion won and 50 manpower. This paper aimed that small scale housing company achieve a zero hazard practising and understanding the safety adminstration standar d model easily and it applied firstly after investigating the operation condition of construction site safety control in small scale company propelling the complex style multiflex housing business.

Application of Flood Prevention Measures Using Detailed Topographic Data of River and Lowland (하천-제내지의 상세 지형자료를 이용한 수해방지대책 적용)

  • LEE, Jae-Yeong;HAN, Kun-Yeun;KEUM, Ho-Jun;KO, Hyun-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.1
    • /
    • pp.15-29
    • /
    • 2020
  • Recently, the incidence of flooding in Korea has decreased by the measures by central and local governments, however the scale of damage is increasing due to the improvement of living standard. One of the causes of such flood damage is natural causes such as rainfall exceeding the planned frequency of flood control under climate change. In addition, there are artificial causes such as encroachment of river spaces and management problems in upstream basins without consideration of downstream damage potential by regional development flood. In this study, in order to reduce the inundation damage caused by flooding of river, the situation at the time of inundation damage was reproduced by the detailed topographic data and 2D numerical model. Therefore, the effect of preparing various disaster prevention measures for the lowland was simulated in advance so that quantitative evaluation could be achieved. The target area is Taehwa river basin, where flooding was caused by the flooding of river waters caused by typhoon Chaba in October 2016. As a result of rainfall-discharge and two-dimensional analysis, the simulation results agree with the observed in terms of flood depth, flood arrival time and flooded area. This study examined the applicability of hydraulic analysis on river using two-dimensional inundation model, by applying detailed topographic data and it is expected to contribute to establish of disaster prevention measures.

A Study on the Safety of Carbon Manufacturing By-product Gas Emissions (카본제조 부생가스 배출 안전성에 관한 연구)

  • Joo, Jong-Yul;Jeong Phil-Hoon;Kim, Sang-Gil;Sung-Eun, Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.