• 제목/요약/키워드: Standard measure

검색결과 1,934건 처리시간 0.03초

Comparisons of obesity assessments in over-weight elementary students using anthropometry, BIA, CT and DEXA

  • Yu, Ok-Kyeong;Rhee, Yang-Keun;Park, Tae-Sun;Cha, Youn-Soo
    • Nutrition Research and Practice
    • /
    • 제4권2호
    • /
    • pp.128-135
    • /
    • 2010
  • Obesity was characterized in Korean elementary students using different obesity assessment tests on 103 overweight elementary students from three schools of Jeonbuk Province. The body mass index (BMI) and obesity index (OI) were compared, and the data using DEXA and CT were compared with the data using BIA and a tape measure. The results of this study are as follows: first, 27 students who were classified as obese by OI were classified as overweight by BMI, and 3 students who were classified as standard weight by BMI were classified as overweight by OI. Secondly, by DEXA and BIA measurements, there was 1.51% difference in body fat percentage (boys 1.66%, girls 1.17%) and the difference in body fat mass between boys and girls was 0.77 kg (boys 0.85 kg, girls 0.59 kg), but those differences in body fat percentage and mass were not statistically significant. Thirdly, the average total abdominal fat (TAF) measured by CT scans of obese children was more significantly related with subcutaneous fat (r = 0.983, P < 0.01) than visceral fat (r = 0.640, P < 0.01). Also, TAF were highest significant with waist circumference by a tape measure (r = 0.744, P < 0.01). In summary, as there are some differences of assessment results between two obesity test methods (BMI, OI), we need more definite standards to determine the degree of obesity. The BIA seems to be the most simple and effective way to measure body fat mass, whereas waist/hip ratio (WHR) using a tape measurer is considered to be the most effective method for assessing abdominal fat in elementary students.

Passive open-path FT-IR spectrometer를 사용한 원거리 화재 연소 가스 정량 분석 (The quantitative analysis of combustive gases on fire by remote passive open path FT-IR spectrometer)

  • 조남욱;조원보;김효진
    • 분석과학
    • /
    • 제26권2호
    • /
    • pp.120-124
    • /
    • 2013
  • 본 연구에서는 대기오염 및 화산활동에 의한 분출가스의 원거리 가스검출에 제한적으로 사용된 개방형 푸리에 변환 분광 분석기(open path FT-IR spectrometer)를 사용하여 적외선광원을 사용하지 않는 passive mode로 $CO_2$, CO, $SO_2$에 대한 정량 분석을 시도하였다. 표준가스를 이용하여 제작된 적외선흡수 스펙트럼으로 $CO_2$, CO, $SO_2$ 다중 회귀 곡선(MLR)을 사용한 농도 별 검량선 작업 결과, $CO_2$, CO는 결정 계수가 0.90 이상으로 선형성이 좋았으나, $SO_2$는 0.88로 비교적 낮은 선형성을 확인할 수 있었다. 실제 화재 실험을 통하여 3가지 가스에 대해서 측정한 결과 $CO_2$는 높은 농도를 확인하였으나, CO, $SO_2$는 확인되지 않았다. 이 결과를 통해서 적외선 광원 없이 개방형 푸리에 변환 분광 분석기를 활용하여 화재시 배출되는 가스의 원거리측정이 가능함을 확인하였다.

칼라 및 다해상도 질감 특징 결합에 의한 영상검색 (Image Retrieval Using Combination of Color and Multiresolution Texture Features)

  • 천영덕;성중기;김남철
    • 한국통신학회논문지
    • /
    • 제30권9C호
    • /
    • pp.930-938
    • /
    • 2005
  • 본 논문에서는 칼라 특징과 다해상도 질감 특징의 효율적인 결합에 근거한 내용기반 영상검색 기법을 제안한다. 칼라 특징으로는 칼라의 공간적인 상관관계를 잘 나타내는 HSV 칼라 오토코렐로그램(color autocorrelogram)을 선택하였고, 질감 특징으로는 국부 밝기 변화와 국부 질감의 부드러움 정도를 잘 측정하는 BDIP와 BVLC를 선택하였다. 이 질감 특징들은 칼라 영상의 휘도(luminance) 성분에서 웨이브렛(wavelet) 분해되어 다해상도로 추출되었다. 그리고 이들 칼라와 질감 특징들은 효율적인 유사도 측정을 위해 각각 이들의 차원들과 표준편차 벡터들에 의해 정규화된 후 결합되었다. 실험을 위한 영상으로는 Corel DB와 VisTex DB, 그리고 이들로부터 파생되어 다양한 해상도의 영상으로 구성된 Corel_MR DB와 VisTex_MR DB를 사용하였다. 실 험 결과, 제안한 방법은 Precision vs. Recall 평가에서 기존의 BDIPBVLC 방법과 칼라 오토코렐로그램 방법보다 각각 평균 $8\%$와 평균 $11\%$ 향상된 성능을 나타내었으며 웨이브렛. 모멘트, CSD, 히스토그램을 이용한 방법들보다 $10\%$ 이상의 높은 성능을 나타내었다. 특히, 제안한 방법이 다른 방법들 보다 다해상도로 구성된 영상 DB에서 높은 검색 성능 차이를나타내었다.

플라즈마발생기의 이온분율 측정 장치 설계 및 제작 (The design and fabricationt for ion fraction measurement of plasma generator)

  • 이찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

LMA를 기반으로 한 캐릭터 동작의 긴장도 측정 (Measuring Tensions of Character Motions based on LMA)

  • 곽창섭;권지용;이인권
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제14권5호
    • /
    • pp.532-536
    • /
    • 2008
  • 본 연구는 Laban이 제시한 모션 분석 기법을 이용하여 모션의 긴장도를 측정하는 방법을 제안한다. 이러한 긴장도 값을 이용하면 캐릭터 모션과 배경음악간의 자동적 동기화를 위한 기준값으로 사용할 수 있다. Laban의 모션 분석 기법, 즉 LMA는 모션을 Effort라고 명명된 4개의 시공간적 요소로 나누고 각 4개의 Effort마다 2가지 상반된 기준을 제시함으로써 모션을 분석하도록 하였다. 이러한 기준을 양적으로 측정하기 위해 우리는 운동학, 역학에 기초한 수식을 제안하고 이를 통해서 계산된 실제 긴장도 값을 실험 데이타에 근거하여 조정하였다. 실험을 통해 제안한 긴장도 측정 결과는 어느 정도 사람의 반응과 비슷한 정도의 순위 판별 능력을 보였다.

웨이블렛 기반 바크 코히어런스 함수를 이용한 VoIP 음질평가 (Speech Quality Measure for VoIP Using Wavelet Based Bark Coherence Function)

  • 박상욱;박영철;윤대희
    • 한국통신학회논문지
    • /
    • 제27권4A호
    • /
    • pp.310-315
    • /
    • 2002
  • 본 논문은 객관적 음질 평가법으로 웨이블렛 변환을 이용한 향상된 바크 코히어런스 함수 (Wavelet based Bark Coherence Function : WBCF)를 제안한다. 바크 코히어런스 함수 (Bark Coherence Function : BCF)는 심리 음향 영역에서 코히어런스 함수를 정의함으로서 음성 통신 시스템의 아날로그 부분에 의하여 발생할 수 있는 선형 왜곡에 강한 객관적 음질 평가법이다. VoIP (Voice over Internet Protocol)와 같은 패킷 기반의 음성 전달 시스템은 가변 지연등이 발생 될 수 있는데, 이것은 원음과 왜곡음의 정확한 시간축 정렬을 불가능하게 하여 기존의 객관적 음질 평가법의 성능을 저하시킨다. 제안된 WBCF는 고주파 영역에서 시간 분해능이 높으며, 저주파 영역에서 주파수 분해능이 높은 웨이블렛 변환을 사용한 후 BCF를 계산하여 VoIP 시스템에서의 객관적 음질을 평가한다. 주/객관적 음질 평가 실험을 통하여 WBCF가 ITU-T 권고안인 Perceptual Speech Quality Measure (PSQM)에 비하여 높은 성능을 가짐을 확인하였다.

일체주조법, 레이저용접법, 납착법, 방전가공법에 의해 제작된 임플란트 보철물의 적합도에 관한 연구 (FIT OF IMPLANT FRAMEWORKS FABRICATED BY ONE-PIECE CASTING, LASER WELDING, SOLDERING, AND ELECTRIC DISCHARGE MACHINING)

  • 설영훈;정창모;전영찬;강성원
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.156-171
    • /
    • 2002
  • The purpose of this study was to measure and compare the strains produced by screw-tightening implant frameworks fabricated by aye different fabrication methods; (1) one-piece cast using plastic sleeve, (2) one-piece cast using gold cylinder, (3) laser welding, (4) soldering, and (5) electrical discharge machining, and also to measure and compare the strains produced when the order of screw tightening was changed A research model incorporating eighteen strain gages was made to measure the fit of implant frameworks in three dimensions. Three implants aligned in an arc were fixed on the top ends of the L-shape aluminum bars of the research model, and standard abutments were joined to the implants with abutment screws. Five types of implant framework were placed on the abutments and screwed by a torque wrench using 10 Ncm. Under the conditions of this study, the following conclusions were drawn: 1. The electrical discharge machining group showed the smallest magnitude of strain, followed by the soldering group, the laser welding group, the one-piece cast group using gold cylinder, and the one-piece cast group using plastic sleeve. However, among the magnitude of strain for the remaining groups except the electrical discharge machining group, there were not significant differences. 2. When the order of screw tightening was changed, there were not significant differences in the magnitude of strain. 3. In comparison with the electrical discharge machining group, the laser welding group and the one-piece cast groups showed greater horizontal distortion and the soldering group showed greater horizontal and vertical distortion.

PHC파일 시공관리 문제점 및 개선방안 (Problem and Improvement Measure of PHC Pile Construction)

  • 박태규;이정철;이찬식
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.344-348
    • /
    • 2008
  • 최근 구조물의 고층화, 대형화 등 여러 가지 사회적 요구에 따라 기존 PC 말뚝의 개선책으로 PHC말뚝이 실용화 되었다. 현재는 대부분의 현장에서 PHC말뚝이 사용되고 있으며, 국내 콘크리트 말뚝 총 생산량의 90%이상을 점유하고 있다. 기성콘크리트 파일 공사의 굴착 및 파일 매입 작업의 국내 시방기준에는 파일을 연직으로 시공해야한다는 것만이 명시되어 있을 뿐, 이에 대한 측정기준 및 시공기준이 제시되어있지 않으며, 대부분의 시공현장에서는 숙련노무자의 경험을 통한 육안측정에 의존하고 있는 실정이다. PHC 파일의 두부정리 작업은 노동집약적이며 단순 반복적인 작업으로 숙련된 노무자에게 많이 의존해왔으며, 파일의 종 방향 균열 및 두부파손 등의 문제점이 발생되고 있다. 본 논문은 PHC 파일 시공 전 과정에서 발생되는 문제점을 분석하고 그에 대한 개선방안을 도출하기 위해 설문조사 및 면담을 실시하였다. 설문조사 및 면담을 통해 파일적재, 현장 내 소운반, 파일위치표시, 연직체크, 굴착 및 항타, 그라인딩, 안전사고의 주요 문제점을 도출하였고, 그에 대한 개선방안을 제시하였다.

  • PDF

강체와 비강체 부품의 정의와 지정방법에 대한 제안 (Suggestions of Define Methods by Rigid/Non-Rigid Parts' Definitions)

  • 김재문;장성호;이왕범
    • 산업경영시스템학회지
    • /
    • 제41권3호
    • /
    • pp.115-119
    • /
    • 2018
  • Defining and measuring non-rigid or flexible parts has been controversial in industry for many years. There are two primary areas of controversy. The first is agreeing on what exactly a non-rigid part is. The second is agreeing on how to define and measure a non-rigid part. The subject of non-rigid parts is further complicated by the brief coverage it receives in the national and international standards. This leaves each company to improvise or create its own rules for non-rigid parts. There are some who believe that Geometrical Dimensioning and Tolerancing (GD&T) should not be used on non-rigid parts. This is not true. The ASME Y14.5M standard applies to rigid parts as a default condition. However, there is no definition given for a rigid part. The term rigid part has been used in industry for so long that it has gained a definition by its general use. When most people in industry say rigid part, they are referring to a part doesn't move (deform or flex) when a force (including gravity) is applied. How much force is relative based on the part characteristics. In reality, all parts will deform (or flex) if enough force is applied. Using this logic, all parts would be considered non-rigid. However, we all know that this is not how parts are treated in industry. Although GD&T defaults to rigid parts, it should also be used on non-rigid parts with a few special techniques. Actually 50~60% of all products designed contain parts or features on parts that are non-rigid. Therefore, we try to suggest the definitions of rigid and non-rigid parts and method to measure non-rigid parts.

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.