• Title/Summary/Keyword: Standard measure

Search Result 1,933, Processing Time 0.03 seconds

Comparative Analysis of Dynamic Moisture Movement Testers

  • Lee, Duck-Weon;Shim, Woo-Sub;Lim, Ho-Sun
    • Journal of Fashion Business
    • /
    • v.15 no.6
    • /
    • pp.40-55
    • /
    • 2011
  • The purpose of this research is to review testing principle, testing design and experimental results of the four dynamic moisture movement testers. The research analyzes Moisture Manager Tester (MMT), Alambeta Instrument, Dynamic Surface Moisture Movement Tester, and Gravimetric Absorbent Testing Method based on American Society for Testing and Material (ASTM) E 96 which is an international standard testing method. Although many of researches use ASTM E 96 to measure moisture movement on a fabric, it has several weaknesses, such as long experimental time and a physical change of sample by a holder of the frame. Hence, lots of researchers have studied and developed the new measurement systems measuring moisture management on a fabric or garment and ultimately mimic heat energy and perspiration created by the human body. These moisture management systems use a variety of parameters, such as electricity, color, and sensor to measure their movement in the fabric. Through comparison with the existing tester (ASTM E 96), the research recognizes the strength and weakness in the dynamic moisture movement testers.

Density Measurement Comparisons of Specific Gravity Meter and Gas Chromatography in the Field (실제조건에서 기준 밀도계와 가스 분석기에 의한 밀도 측정 결과 비교)

  • Lee, Kang-Jin;Her, Jae-Young;Ha, Young-Cheol
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.90-96
    • /
    • 1999
  • In contracts for sales of natural gas between sellers and buyers, it is not suncient to only measure a volumetric quantity of gas in flowing conditions in metering station. Therefore the measured volumetric quantity must be converted to that of reference conditions. The density of the natural gas required in such a calculation can be measured directly or estimated from the equation of sate or any other experimental methods. The specific gravity meter is the apparatus used to measure the density of fluids under the reference conditions and it can be widely used in industrial areas, especially in massive flow rate natural gas industry. This study has been carried out in an attempt to improve measurement accuracy of natural gas flow rate calculation, providing the adequate installation and proper operation conditions of specific gravity meter. The test results are 1) the density measurement errors in case of using methane and standard gas as calibration gases are smaller than using methane and nitrogen gas, 2) the periodical calibration to maintain accurate density measurements is essential, and 3) the specific gravity meter is sensitive to changes of environmental conditions, especially environmental temperature surrounding the specific gravity meter.

  • PDF

Ratio-type Capacitance Measurement Circuit for femto-Farad Resolution (펨토 패럿 측정을 위한 비율형 커패시턴스 측정 회로)

  • Chung, Jae-Woong;Chung, In-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.989-998
    • /
    • 2012
  • A ratio type of capacitance measurement circuit is proposed to measure an extremely small value of the fF capacitance on this paper. This measurement circuit is formed with a switched-capacitor integrator, a comparator, and logic circuit blocks to control the switches. It converts the measured ratio value between the known value of on-chip capacitor and the unknown value of capacitor to the digital signal. The fF capacitance with minimized error can be obtained by calculating this ratio. This proposed circuit is designed with standard CMOS $0.18{\mu}m$ process, and various HSpice simulations prove that this capacitance measurement circuit is able to measure the capacitance under 5fF with less than ${\pm}0.3%$ error rate.

Development of a Sensor System to Measure Real Time Vibro Displacement of Civil Structure (레이저 센서를 이용한 구조물의 변위 측정 장비 개발)

  • O, Heung-Il;Kim, Hui-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.823-825
    • /
    • 2003
  • A sensor system was designed to measure real time vibro displacement of civil structure. The He-Ne laser is used for the displacement measuring method, because it guarantees short time stabilization, long time output power stability. Also, it guarantees simple maintenances and repairs under actual using condition. The line CCD image sensor(Tcd-142d) is used to detect the displacement of Ne-Ne laser responding to the vibro of civil structure. For accurate measurement and comparison, CDP-50 is used. Usually CDF-50 (Strain type displacement device) is used for the standard correction device of optical measurement equipments. The data processing part is consists of Optical sensor part, Wireless data transmission device, DAQp-1200, and LapView program. The displacement data of vibro from optical sensor part inputted to wireless data transmission device and then transmitted to DAQp-1200 in main control room. DAQp-1200 performs A/D conversion for the receiving data. After that the converted data inputted to computer system using LapView program for user display. The significance of this paper is to develope a convenient, accurate and lost saving real time displacement measurement system for the civil structure.

  • PDF

Studies on Exploring Math. Disliking Factors and Devising Tools to Analyze Students' Disliking Trends about School Mathematics (수학 기피요인의 설정 및 기피성향의 분석도구 개발)

  • 김영국;박기양;박규홍;박혜숙;박윤범;유현주;권오한;이선아
    • The Mathematical Education
    • /
    • v.40 no.2
    • /
    • pp.217-239
    • /
    • 2001
  • To lessen the ratio of under achievers is one of the most urgent task which recent school mathematics education is confronted with. To cope with this problem efficiently, math. teachers should know more specifically and concretely the causes that make the students dislike mathematics. But actually, there are too many reasons for these situations. So, in this paper, we tried to devise a tool to analyze and measure each student's math. disliking status. We proceeded this research via the following procedures. 1. Grasping the causes which make the students dislike mathematics as specifically as possible. To obtain this, we asked more than 300 of secondary school students to write down their thoughts about school mathematics. 2. Analyzing the responses, we abstracted 74 numbers of items which were supposed to be the causes for secondary school students'mathematics disliking. 3. With these items we made a test to measure students'aptitude for each item. 4. With this test paper, we tested over 800 of secondary school students. Through factor analysis and theoretical argument, we categorized the 74 items into 11 groups whose names were defined as factors of mathematics disliking. 5. For each of these 11 factors, we developed a norm which could serve as standard of comparison in measuring each student's mathematics disliking status. Using this tool teachers were able to describe each student's traits of mathematics disliking more specifically.

  • PDF

Development of the System for Measurement of the Vibration Transmissibility of an Anti-vibration Glove (방진 장갑 진동 전달률 측정 시스템 개발)

  • Choi, Seok-Hyun;Hong, Seok-In;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.602-608
    • /
    • 2006
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing and evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm system. Whole procedure of ISO 10819 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of vibration transmissibility were also calculated.

The Study on Undergraduates' Information Literacy Scale Development (대학생이 정보활용능력 척도 개발 연구)

  • Lee, Hey-Young;Nam, Tae-Woo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.42 no.4
    • /
    • pp.503-532
    • /
    • 2008
  • This study is on information literacy standards and models analysis, which will be used as the source material to measure undergraduates' information literacy. After main areas and items that are analyzed with three standards and two models are proposed, finally item model(proposal) for scale development is proposed. It consists of six main areas and eighteen items. The scale development item model(proposal) proposed in this study will be used as the source material to measure undergraduates' information literacy that will be studied in future.

Complex Korean Medical Treatment after Embolization for Myelopathy Due to Spinal Dural Arteriovenous Fistula: A Case Report (척수경막동정맥루로 인한 척수병증 환자의 색전술 이후 한의복합치료: 증례 보고)

  • Woo, Hyeon-Jun;Han, Yun-Hee;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.3
    • /
    • pp.105-114
    • /
    • 2021
  • A 38-year-old Korean man without any other history was diagnosed with myelopathy due to a spinal dural arteriovenous fistula. Following embolization and high-dose steroid therapy, the patient was treated with complex Korean medical therapies including acupuncture, pharmacopuncture, electro-acupuncture, Chuna manual therapy, herbal medicine, and cupping therapy in addition to conventional treatment. To assess the patient's improvement, international standard for neurological classification of spinal cord injury, Korean version of modified Barthel index, functional independence measure, spinal cord independence measure III, walking index for spinal cord injury II, modified Ashworth scale were used. After treatment, the muscle strength and sensory function of the lower extremities were improved, and the spasticity was reduced, resulting in a rapid improvement in performance of daily activities. These results suggest that complex Korean medical therapies may be effective for myelopathy, and further clinical studies are needed to clarify their effects.

Factors affecting modulation transfer function measurements in cone-beam computed tomographic images

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.131-137
    • /
    • 2019
  • Purpose: This study was designed to investigate the effects of voxel size, the oversampling technique, and the direction and area of measurement on modulation transfer function (MTF) values to identify the optimal method of MTF measurement. Materials and Methods: Images of the wire inserts of the SedentexCT IQ phantom were acquired, and MTF values were calculated under different conditions(voxel size of 0.1, 0.2, and 0.3 mm; 5 oversampling techniques; simulated pixel location errors; and different directions and areas of measurement). The differences in the MTF values across various conditions were evaluated. Results: The MTF 10 values showed smaller standard deviations than the MTF 50 values. Stable and accurate MTF values were obtained in the 0.1-mm voxel images. In the 0.3-mm voxel images, oversampling techniques of 11 lines or more did not show significant differences in MTF values depending on the presence of simulated location errors. MTF 10 values showed significant differences according to the direction and area of the measurement. Conclusion: To measure more accurate and stable MTF values, it is better to measure MTF 10 values in small-voxel images. In large-voxel images, the proper oversampling technique is required. MTF values from the radial and tangential directions may be different, and MTF values vary depending on the measured area.

A Proposal of a Smart Work Environmental Management Service Model for Small Business (소규모 사업장 대상 스마트 작업환경관리 서비스 모델 제안)

  • An, Woo-Ju;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.2
    • /
    • pp.128-137
    • /
    • 2021
  • Objectives: The purpose of this study is to propose a smart work environment management service model that can measure and maintain work environments in real time. Methods: How existing private consignment business is being carried out was identified and a simpler method was applied to the model. Results: Common support was provided according to the Korea Standard Industrial Classification. Hazards suitable for the relevant industry classification were selected and information on safety and health education, etc. was provided. Theme-specific support provides services focusing on hazards that can be measured through applications. Hazards are evaluated by applying new standards divided into 'Good', 'Average', 'Inadequate', and 'Faulty'. Conclusions: This model is designed to help employers identify health and safety conditions in small businesses where it is difficult to hire health and safety professionals. Using the app proposed in this study, anyone can easily measure their work environment at any time.