Comparative Analysis of Dynamic Moisture Movement Testers

  • Lee, Duck-Weon (Department of Fiber and Polymer Science, North Carolina State University) ;
  • Shim, Woo-Sub (Next-Generation Color Patterning Group, Research Institute, Samsung Mobile Display) ;
  • Lim, Ho-Sun (Department of Clothing and Textiles, Yonsei University)
  • Received : 2011.09.15
  • Accepted : 2011.11.28
  • Published : 2011.12.30

Abstract

The purpose of this research is to review testing principle, testing design and experimental results of the four dynamic moisture movement testers. The research analyzes Moisture Manager Tester (MMT), Alambeta Instrument, Dynamic Surface Moisture Movement Tester, and Gravimetric Absorbent Testing Method based on American Society for Testing and Material (ASTM) E 96 which is an international standard testing method. Although many of researches use ASTM E 96 to measure moisture movement on a fabric, it has several weaknesses, such as long experimental time and a physical change of sample by a holder of the frame. Hence, lots of researchers have studied and developed the new measurement systems measuring moisture management on a fabric or garment and ultimately mimic heat energy and perspiration created by the human body. These moisture management systems use a variety of parameters, such as electricity, color, and sensor to measure their movement in the fabric. Through comparison with the existing tester (ASTM E 96), the research recognizes the strength and weakness in the dynamic moisture movement testers.

Keywords

References

  1. M. Wallace(2002), "100% cotton moisture management", Journal of Textile and Apparel, Technology and Management, 2(3), pp.1-11.
  2. P. R. Hernett, P. N. Mehta(1984), "A survey and comparison of laboratory test methods for measuring wicking", Textile Research Journal, 54(7), pp.471-478. https://doi.org/10.1177/004051758405400710
  3. ASTM E96(2000), Standard Test Methods for Water Vapor Transmission of Materials, Philadelphia: Annual Book of ASTM Standards, pp.907-914.
  4. C. Prahsarn, R. L. Barker, B. S. Gupta (2005), "Moisture vapor transport behavior of polyester knit fabrics", Textile Research Journal, 75(4), pp.346-351. https://doi.org/10.1177/0040517505053811
  5. M. M. Adler, W. K. Walsh(1984), "Mechanisms of transient moisture transport between fabrics", Textile Research Journal, 54(5), pp.334-343. https://doi.org/10.1177/004051758405400510
  6. J. Hu, Y. Li, K. W. Yeung, A. S. W. Wong, W. Xu(2005), "Moisture management tester: A method to characterize fabric liquid moisture management properties", Textile Research Journal, 75(1), pp.57-62. https://doi.org/10.1177/004051750507500111
  7. Y. Li, B. V. Holcombe(1998), "Mathematical simulation of heat and moisture transfer in a human-clothing-environment system", Textile Research Journal, 68(6), pp.389-397. https://doi.org/10.1177/004051759806800601
  8. N. V. Bhat, A. R. Dharmadhikari, S. N. Wani, S. D. Kulkarni(1990), "Effect of perspiration on the fine structure of cotton fabrics", Textile Journal Research, 60(4), pp.240-244. https://doi.org/10.1177/004051759006000408
  9. K. Kraning, E. G. Schibili, S. T. Mornii, E. A. Merrick(1978), "A gas stream heater to control local skin temperature under evaporative sweat capsules", Journal of Applied Physiology, 44(6), pp.981-985.
  10. L. Hes, M. D. Araujo, V. V. Djulay(1996), "Effect of mutual bonding of textile layers on thermal insulation and thermal contact properties of fabric assemblies", Textile Journal Research, 66(4), pp.245-250. https://doi.org/10.1177/004051759606600410
  11. O. Koronthalyova, P. Matiasovsky(2003), "Thermal conductivity of fibre reinforced porous calcium silicate hydrate-based composites", Journal of Building Physics, 27(1), pp.71-89. https://doi.org/10.1177/1097196303027001005
  12. J.P. Dionne, K. Semeniuk, A. Makris, W. Teal, B. Laprise(2003, February 23-27), "Thermal manikin evaluation of liquid cooling garments intended for use in hazardous waste management", WM'03 Conference, Retrieved 2011. 9. 15, from http://www.wmsym.org/archives/2003/pdfs/58.pdf
  13. J. P. Fohr, D. Couton, G. Treguier(2002), "Dynamic heat and water transfer through layered fabrics", Textile Research Journal, 72(1), pp.1-12. https://doi.org/10.1177/004051750207200101
  14. L. Hes(2008), "Heat, moisture and air transfer properties of selected woven fabrics in wet state", Textile Bioengineering and Informatics Society, Retrieved 2011. 10. 11, from http://www.jfbi.org/admin/Issue/TBIS%202008_2008930155327_paper.pdf
  15. W. Bendkowska, J. Tysiak, L. Grabowski, A. Blejzyk(2005), "Determining temperature regulating factor for apparel fabrics containing phase change material", International Journal of Clothing Science and Technology, 17(3/4), pp.209-214. https://doi.org/10.1108/09556220510590902
  16. R. Lomax(1990), "Hydrophilic polyurethane coatings", Journal of Industrial Textile, 20, pp.1-21.
  17. D. M. Scheurell, S. M. Spivak, N. R. S. Hollies(1985), "Dynamic surface wetness of fabrics in relation to clothing comfort", Textile Research Journal, 55(7), pp.394-399. https://doi.org/10.1177/004051758505500702
  18. J. Huang(2007), "A new test method for determining water vapor transport properties of polymer membranes", Polymer Testing, 26(5), pp.685-691. https://doi.org/10.1016/j.polymertesting.2007.04.005
  19. M. Jassal, A. Khungar, P. Bajaj, T. J. M. Sinha(2004), "Waterproof breathable polymeric coating based on polyurethanes", Journal of Industrial Textile, 33(4), pp.269-280. https://doi.org/10.1177/1528083704045179
  20. A. C. F. Ribeiro, V. M. M. Lobo, J. J. S. Natividade(2002), "Diffusion coefficients in aqueous solutions cobalt chloride at 298.15 K", Journal of Chemical & Engineering DATA, 47(3), pp.539-541. https://doi.org/10.1021/je0101808
  21. F. B. Braton, D. S. Fong, G. L. Knatterud, ETDRS Research Group(2004), "Classification of farnworth munsell 100-hue test results in the early treatment diabetic retinopathy study", American Journal of Ophthalmology, 138(1), pp.119-124. https://doi.org/10.1016/j.ajo.2004.02.009
  22. B. C. Roberts, T. M. Waller, M. P. Caine(2007), "Thermoregulatory response to base-layer garments during treadmill exercise", International Journal of Sports Science and Engineering, 1(1), pp.29-38.
  23. B. Farnworth, W. A. Lotens, P. M. Wittgen (1990), "Variation of water vapor resistance of microporous and hydrophilic film with relative humidity", Textile Research Journal, 60(1), pp.50-53. https://doi.org/10.1177/004051759006000107
  24. T. W. Ng, W. K. Yeong(2005), "Inexpensive color evaluation of dyed-based pressuresensitive films for plantar studies", Journal of Biomechanics, 38(10), pp.2130-2133. https://doi.org/10.1016/j.jbiomech.2004.09.007
  25. S. Yoo, R. L. Barker(2005), "Comfort properties of heat-resistant protective workwear in varying conditions of physical activity and environment, Part I: Thermophysical and sensorial properties of fabrics", Textile Journal Research, 75(7), pp.523-530. https://doi.org/10.1177/0040517505053949
  26. N. Ansari, M. H. Kish(2000), "The wicking of water in yarn as measured by an electrical resistance technique", Journal of Textile Institute, 91(3), pp.410-419. https://doi.org/10.1080/00405000008659517
  27. R. M. Laing, et al.(2007), "Response of wool knit apparel fabrics water vapor and water", Textile Research Journal, 77(3), pp.165-171. https://doi.org/10.1177/0040517506069157
  28. B. Das, A. Das, et al.(2007), "Moisture transmission through textiles, Part II: Evaluation methods and mathematical modeling", AUTEX Research Journal, 7(3), pp.194-216.
  29. A. B. Nyoni, D. Brook(2006), "Wicking mechanisms in yarns-The key to fabric wicking performance", Textile Research Journal, 97(2), pp.119-128.
  30. P. Gibson, M. Charmchi(1997), "The use of volume-averaging techniques to predict temperature transients due to water vapor sorption in hygroscopic porous polymer materials", Journal of Apply Polymer Science, 64(3), pp.493-505. https://doi.org/10.1002/(SICI)1097-4628(19970418)64:3<493::AID-APP6>3.0.CO;2-F
  31. P. Gibson(2008), "Water-repellent treatment on military uniform fabrics: Physical and comfort implications", Journal of Industrial Textile, 38(1), pp.43-54. https://doi.org/10.1177/1528083707087833