• Title/Summary/Keyword: Standard measure

Search Result 1,921, Processing Time 0.028 seconds

Introduction of High Resolution Spectrograph by using Optical Freauency Comb.

  • Han, In-Woo;Kim, Kang-Min;Yoon, Tai-Hyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.36.1-36.1
    • /
    • 2010
  • OFC (Optical Frequency Comb) is an optical spectrum which consists of equidistant lines in frequency space. OFC can thus be used as an optical ruler. Since it was demonstrated in late 1990s, it is revolutionizing many fields in frequency metrology such as the measurement of absolute optical frequencies, the measure ratios of optical frequencies with extremely high precision. It is also used in high-precision spectroscopy. In astronomy, OFC can be used as a very accurate and stable wavelength standard for a high resolution spectrograph to measure the radial velocity of celestial bodies with extremely high accuracy of about several tens cm/s. In our presentation, we will introduce some basic concepts of OFC and some issues to use it in astronomical spectrograph. We will also present our plan to develop a high resolution spectrograph with OFC.

  • PDF

A Study on the High-Accuracy Power Meter and Reliability Verification Plan (고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구)

  • Lee, Sanghun;LEE, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

Measurement of Sucrose Concentration Using a μFIA Biosensor (μFIA 바이오센서를 이용한 자당 농도 측정)

  • Song D. B.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.553-557
    • /
    • 2004
  • A microdialysis coupled flow injection amperometric $({\mu}FIA)$ biosensor was calibrated to measure the concentration of sucrose using 11 standard samples from 2 ml to 70 ml of sucrose solution. The output of the sensor increased linearly with an increase in the sucrose concentration with an $r^2$ correlation of 0.99. The amperometric biosensor was then applied to measure the sucrose concentration of 4 commercial samples (Orange and Pineapple juices, Pepsi, Sprite) and the results compared with those by HPLC. Around $20\~30\%$ error was observed in sucrose concentration measurements of the samples analyzed. The sensor has potential in rapid measurement once the calibration is done. Potential for on-line sensing is also discussed.

A study on body cathexis and clothing satisfaction of married women. (기혼 여성들의 신체만족도와 의복만족도에 관하여)

  • 김용숙
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.3
    • /
    • pp.1-9
    • /
    • 1986
  • The purpose of this study was to measure the body cathexis and clothing satisfaction sccording to the level of age, job, and total monthly income and to investigate the relationship between body cathexis and clothing satisfaction of married women. 43 items of body parts and body functions were selected to measure body cathexis from Secord and jourard body Cathexis scale. A nd 56 items of Mclean's Clothing Satisfac tion scale were used for clothing satisfaction. The questionnaires were administered to 384 mothers in Jeonbug province. 3-way ANOVA and Newman-Keuls test were used for group difference. Pearson's Correlation Coefficients, Partial Correlation Coefficients, Standard Deviation, and Mean were calculated. RESULTS : 1. Body cathexis of married women showed asignificant difference according to age. 2. Clothing satisfaction of married women showed a significant difference to the interaction of age, job, and total monthly income. The elder and higher income group without job had the highest clothing satisfaction scores than any other group. 3. Positive correlations were found among body cathexis, clothing satisfaction, and 6 subscales of clothing satisfaction.

  • PDF

Simulating Rotation Measure toward High Galactic Latitude

  • Akahori, Takuya;Ryu, Dong-Su;Kim, Jong-Soo;Gaensler, Bryan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.116.2-116.2
    • /
    • 2011
  • We investigate Faraday rotation measure (RM) toward high Galactic latitudes due to the Galactic magnetic field (GMF). The Galactic contribution to RM comes from the global component and the turbulent component of the GMF, and we newly model the latter by incorporating data of MHD turbulence simulations. We find that for the turbulent velocity of ~50 km/s, the standard deviation of the RM due to the GMF toward high Galactic latitudes is close to the observed value, several rad m^{-2}. Yet, the predicted second-order structure function (SF) has values substantially smaller than the observed ones at separation angles of <~ several degree. This suggests that the intergalactic magnetic field (IGMF) significantly contributes to RM toward high Galactic latitudes, particularly at small angular scales. Our work proposes a strategy for surveys to explore the IGMF with LOFAR, ASKAP, MeerKAT, and SKA.

  • PDF

The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor (보정계수 산출에 의한 신광원용 표준램프 광속의 검증)

  • Hwang, Myung-Keun;Shin, Sang-Wuk;Yi, Chin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.

Development of Effective Industrial Safety Index and Application (체감 산업안전 평가지수 개발과 그 응용에 대한 연구)

  • Kim, Yu-Chang;Kim, Yei-Chang
    • IE interfaces
    • /
    • v.14 no.1
    • /
    • pp.106-110
    • /
    • 2001
  • The importance of development of occupational safety index is truly great. It will contribute to the wise direction of safety program. In present, frequency and severity ratios were the standard measure. These terms express the incidence of major injuries and severity of the major injuries experience, each with relation to the employee-hours of work exposure during the period that is measured. But these measure don't expressed the dangerous feeling degree of worker. In this study, Effective Industrial Safety Index(EISI) was developed using dangerous feeling degree of worker, frequency of injuries, and severity of injury. EISI can be used as an aid for effective safety management in workplace.

  • PDF

A Study on Non-contact Measurement of 3D-Objects by Optical Probe Method (광촉침법에 의한 비접촉 3차원 형상측정에 관한 연구)

  • Kang, Young-June;Shin, Seong-Kook;Miyoshi, Takashi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.119-126
    • /
    • 1995
  • This paper presents a non-contact measuring system using one point measuring method to measure surface profiles of dies and clay models for practical use in the field of production engineering. The system has a laser beam probe similar to a measuring probe in a contact measuring system and CCD linear sensor used to detect 300mm measurement range, displacement of measured surfaces, from an origin. There is no mechanical interference between this measuring system and a measured surface in this system. In this measuring system, it was needed 500-600ms including data processing time to measure one point. The experiments showed that the standard deviation was 800 .mu.m and the reproducibility was also 100-210 .mu. m.

  • PDF

Development and Calibration of a Plate Type Eddy Current Standard (평판형 와전류 표준 시험편의 개발 및 교정)

  • Kim, Young-Joo;Kim, Young-Gil;Ahn, Bong-Young;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.393-397
    • /
    • 2007
  • Eddy current standard including an artificial slot for the calibration of absolute type surface probe was fabricated. Developed eddy current standard has the electric conductivity and dimensions, and contains artificial slot as established in ASTM E 1629. The width and depth of artificial slot are 0.1 mm and 0.5 mm respectively. This slot was only possible to measure the depth on the two side edges, and impossible for the middle part with general measurement tools. The ultrasonic test method was applied for measuring depth of the middle part of the artificial slot in the standard. Using this method the dimension could be measured successfully with uncertainty about $15\;{\mu}m$. Calibration of eddy current standard for the absolute probe can be performed by this technique.

A Study on Development of the Measure of Effects for Pallets Standardization (파렛트 표준화의 효과평가척도 개발에 관한 연구)

  • Kim, Hyeon-Seung;Do, Hwa-Yong;Park, Dong-Ju;Choe, Chang-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.1
    • /
    • pp.97-105
    • /
    • 2009
  • It is expected that logistics standardization have an great effect on industry and national economy due to cost saving and improving efficiency. Therefore all countries of the world make a strenuous effort to take a lead of logistics standardization Despite such efforts of every country, our country remained a lukewarm attitude about logistics standardization. Especially, our country remained a lukewarm attitude about logistics standardization effect quantify. We have to suggest the necessity of standardization and the effect for carrying out logistics standard. So, this study performed literature review and case study for development of effect valuation method. Also, this study developed effect valuation standard for quantifiable standardization effect and drew the effect valuation standard model. First, the measure of preliminary effectiveness was chosen for MOE selection. As a results, vehicle load ratio, delivery cost, keeping space efficiency warehouse automation ratio, etc. were selected. Then, vehicle/truck load ratio, warehouse keeping efficiency, up unloading hour, packaging cost, consistency transportation ratio were chosen for MOE of pallet standardization.