Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • v.77 no.5
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.

A Study Comparing Korean, Chinese, and Japanese Fire Investigation Operating System (한.중.일 화재조사 운영체제 비교연구)

  • Choi, Jin-Man;Kim, Kil-Hwan
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.56-63
    • /
    • 2011
  • When enforcing fire investigation, duty for basic principles, responsibility of investigation, report deadline, and all sorts of standard forms are based on fire investigation report regulation which is internal instructions. This study has a purpose to prepare alternatives that are absent in Korea or have to be strengthened by comparing and examining Japanese and Chinese fire investigation report regulations with Korean one. As a result, it appears that Korea needs to standardize the report deadline of urgency fire and general fire into 30 days when additional investigation is needed, have investigators draw delays reports up when they exceed the deadline not to make work vacuum, and found and organize forms of certificate of custody and return for all fire related materials when investigators require data from fire-related people, to improve whole systems.

Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires (화원에 따른 광전식 연기감지기 반응시간 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

Comparison on the fire performance of additional insulation materials for improving the fire retardancy in engine-room of FRP vessel (FRP 선박 기관실 난연성 향상을 위한 추가 방열재의 화재성능비교)

  • Choi, Jung-Min;Um, Han-Chan;Jin, Young-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1150-1155
    • /
    • 2014
  • To prevent the flame spread in FRP vessel in fire, the engine-room of the vessel should be constructed additionally with laminated fire-retardant resin over 3 times or equivalent insulation materials to former according to the relevant standard for FRP vessel structure. It is surveyed that insulation materials called 'Gel coat' are widely used in FRP fishing vessel, however, test method and its criteria for Gel coat are not clearly establish and have not been evaluated yet, while test method and criteria for fire-retardant resin and fire-retardant polyurethane composite are described in test standard for type-approval. In this study, 3 fire-retardant resins, 4 gel coats, 1 flame-retardant paint and 1 polyurethane composite were selected based on the survey and were evaluated according to both IMO FTP Code part 5 and flame-retardant test. When comparing based on CFE values from flame-spread test, average value for 4 gel coats were lower than that of 3 fire-retardant resins. As for flame-retardant test, there were no significant differences between fire-retardant resin and gel coat, based on charred area.

A Study on the Friction Loss Reduction in Fire Hoses Used at a Fire Scene (화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.52-59
    • /
    • 2013
  • It was described the measured friction loss depending on pressure used and changes in water flow rates for a fire hose used at a fire scene on this study. As a result of actual measurement based on the result obtained by analyzing the use situation of a fire hose such as the kind, quantity, pressure used, etc. of a fire hose, the friction loss in a fire hose under the condition of using by a fire officer at a fire scene was measured as up to 56.8 %. This is much different from the equivalent length of a fire hose used to calculate the pump head in an indoor and outdoor fire-fighting facility. There is no related restrictive regulation on friction loss, there are even no data on friction loss measured by fire hose makers, and spreading a fire hose without considering friction loss at a fire scene can result in an increased length of hose used and a high-pressure water discharge from a fire engine, so this study aims to establish a standard for an equivalent length to friction loss in a fire hose and to propose a spreading method considering friction loss in a fire hose at a fire scene.

국내 방폭전기 안전 기준 제정 배경 및 방폭지역 구분 요령

  • Jeong, Jae-Jong
    • Fire Protection Technology
    • /
    • s.15
    • /
    • pp.22-27
    • /
    • 1993
  • The classification of hazardous area is a method of analysing and classifying the environment where explosive gas or vapour atmosphere may be expected to be present. The object of area classification is to enable the proper selection and installation of electical apparatus and other equipments. This report is intended to serve a general reference about the classification procedure of hazardous area with explanations of related Korean Standard.

  • PDF

Review on the detailed standards for Quantitative Risk Analysis in High Speed Railway Tunnels (고속철도 터널의 정량적 위험도 분석(QRA)을 위한 세부기준에 관한 고찰)

  • Choi, Won-Il;Choi, Jeong-Hwan;Moon, Yeon-Oh;Kim, Seon-Hong;Yoo, Ho-Sik
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.393-407
    • /
    • 2008
  • To protection of fire accident and to minimize danger of spreading the disaster. in railway tunnel, MCT (the Ministry of Construction and Transportation) published "Rules about the Safety Standard of Railroad (2005.10.27)" and "The Detailed Safety Standard of Railroad (2006.9.22)". QRA(Quantitative Risk Analysis) results are applied to establish the fire protection facilities in railway tunnel so that institute the reasonable application about the fire safety facilities However, it is difficult to perform the fire safety design due to lack of the detailed standards about event scenario, fire intensity, incidence rate of accidents etc. Therefore, This paper introduces the practical method about detailed standards of QRA.

Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures (뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체 제안을 위한 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.7-15
    • /
    • 2016
  • The cross-sectional shape factor is used worldwide to evaluate the scientific performance of fire-resistant structures. In South Korea, however, a system for applying a cross-sectional shape factor has not been arranged and circular or rectangular steel pipes are commonly used for large-scale steel frame buildings. On the other hand, coating material-spray steel beams and pillars that have received the certification of a fire-resistant structure from recognized organizations are mostly limited to a H-beam. A H-beam is granted a wide range of certifications without size limitations from a non-loading performance test with test standards based on the relevant provisions. Other types of steel pipe are to be certified for fireresistance according to shape. In this study, a cross-sectional shape factor was used to propose standard testing specifications for the application of coating material-sprayed circular and rectangular steel pipes, eventually to set the scope of certification for reasonable fire-resistant structures.

Performance Analysis of the the Single Alarm Detector in the Rooms of Single Houses by Computer Simulation (시뮬레이션을 통한 주거공간 단독경보형감지기의 성능 분석)

  • Lim, Geun-Joo;Park, Sang-Cheon;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.29-35
    • /
    • 2020
  • This study was conducted to examine the performance in the space for a single alarm type detector installed in a single house. Three types of houses were used, including two types of one-story and two-story houses. A computer simulation program was used to predict the sound pressure level in response to the occurrence of an alarm sound in a residential space. The characteristics of the sound source applied to the simulation were directly measured and used as input data. As a result of simulation, it was found that the sound pressure level in the kitchen and living room generally met the standard when the alarm sound of the detector occurred. However, the sound pressure level in the bedroom was predicted to be at least 20 dB (A) lower than the American Fire Protection Association standard of 75 dB (A). Therefore, a plan should be prepared to maintain a sufficient sound level in the bedroom space inside the house, and efforts will be needed to ensure safe evacuation in case of fire by establishing relevant standards.

Standard for Quake Prevention Design of Fire Extingushing System (소화설비 시스템의 내진설계 기준안 정립)

  • Lee, Chnag-Wook;Kim, Won-Gyu
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.42-45
    • /
    • 2012
  • 최근 국내 지진 발생 위험이 높아짐에 따라 지진 시 소방시설이 정상적으로 작동할 수 있도록 규정할 수 있는 개정법률안이 발표되었다. 소방시설설치유지 및 안전관리에 관한 법률 제 9조의 2에 신설되어 있으며 지진이 발생할 경우 소방시설이 정상적으로 작동될 수 있도록 내진성능이 확보된 소방시설을 설치하도록 규정하고 있지만 그 세부기준은 아직 제시되어 있지 않다.

  • PDF