• Title/Summary/Keyword: Standard facility

Search Result 926, Processing Time 0.027 seconds

EPMA Analysis of Inter-reaction Layer in Irradiated U3Si-Al Fuels (EPMA를 이용한 U3Si/Al 조사 핵연료의 반응층 분석)

  • Jung, Yang-Hong;Yoo, Byung-Ok;Kim, Hee-Moon;Park, Jong-Man;Kim, Myung-Han
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.355-362
    • /
    • 2004
  • Fission products and Inter reaction layer of $U_3Si-Al$ dispersion fuel, irradiated in HANARO research reactor with 121 kW/m of maximum liner power and 63 at% of average burn-up, was characterization by EPMA (Electron Probe Micro Analyzer). The fuel punching system developed by Irradiated Materials Examination Facility (IMEF) has used to make these samples for the EPMA. With this system a very small and thin specimen which is 1.57 mm in diameter and 2 mm in thickness respectively has been fabricated to protect the EPMA operator from high radioactive fuel and to mini-mize the equivalent dose rate less than 150 mSv/h. EPMA was performed to observe layers of sectional, Inter-reaction and oxide with specimens of cutting and polished. Stoichiometry in the Inter-reaction layer with $16{\mu}m$ of thickness was $U_{2.84}$ Si $Al_{14}$ with calibration of $UO_2$ and $U_{3.24}$ Si $Al_{14.1}$ with calibration of standard specimen. metallic precipitates in this layer were not observed using fission products examination.

Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model (축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom;Kwon, Sin-Won;Gil, Kyung-Suk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

Optimum Allocation Modelling of Rural Facilities by Decision-Making Technique - With Special Reference to Agricultural-cum-Industrial Complex- (의사결정기법을 이용한 농촌지역시설 적정입지선정 모델 - 농공단지를 중심으로 -)

  • Choe, Su-Myeong;Kim, Yeong-Ju;Hwang, Han-Cheol
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.1
    • /
    • pp.98-107
    • /
    • 1998
  • For efficient development of rural facilities, choice of their optimum locations would be an important issue, however, existing research works concentrated much more an allocation policy of urban industrial complex and public facilities than rural ones. In this study, because agricultural-cum-industrial complex has been the most widely developed representative one of rural facilities, it was selected as a case study facility. As a pre-study to system development, existing governmental location-decision system was checked and interviewing survey carried out to find out on-spot problems. And, being based on literature review and survey analysis results, 4-step optimum locational decision model was developed , formulation of locational goal system, ranking tabulation on components, determination of significance values of components, calculation of component scores. Finally, through the case study works on 3 sites, system applicability was checked, Considering together the simplicity problem of existing guidelines and the interviewing survey results favoring the diversified viewpoints, it would be necessary to develop multifaceted support system for locational decision making. 3-tier classification steps from the higher, middle to lower one were used and their underpinning viewpoints were sorted as on regional development, entrepreneurship, spatial rationality, from which a tentative locational goal system was formulated. Through the expert group checking, final locational goal system was determined having 3 of the higher classification items, 7 of the middle ones, 23 of the lower ogles. For ranking tabulation, 3 types of ranking criteria were arranged which were based on statistical analysis using mean and standard deviation(Type I ), its existence or not 1 good or not(Type E ), and the others(Type E ). From the significance evaluation results, regional development and entrepreneurship aspects were valued much higher than spatial rationality aspect. And, in the middle step, items as spread effects of regional economy, accessibility and social potentialities were highly valued while infrastructural development level and natural condition being low. The application results of the system to 3 case study total. However, the detailed ones differed among study the influencing effects on regional economy, and contrast greater the infrastructural development level. Conclusively, final evaluation values well represented the characteristics of each area. If this system be complemented and applied comprehensively by the successive studies, it would be developed to a general model of locational decision supporting system for rural facilities.

  • PDF

Farm Animal Mortality Management Practices in Sunchon-si (순천시의 폐사가축 처리실태에 관한 연구)

  • Hong, Ji-Hyung
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • Disposal methods of managing carcass in Korea livestock production systems include burying, digesting, rendering, carcass dumping to manure pile, dead animal disposer and mini-incinerator. Burying was usually the most practical method of carcass disposal in our livestock farms. Burying, carcass dumping to manure pile, dead animal disposer and mini-incinerator may have environmental regulatory and economic liabilities when used as a means of carcass disposal. In many cases in this survey, these disposal methods offer a poor choice for the producer due to individual site conditions, geology, cost, air emissions, rendering plants. A survey questionnaire that addressed the issues to livestock producers was prepared. The questionnaire addressed two main topics as follows: 1) types of livestock and generation amounts of carcass 2) Number of breeding animals and disposal methods of livestock mortality. A total of 36 livestock producers were interviewed. The results of obtained in this survey were summarized as follows: The number of breeding poultry, swine, beef cow and dairy cow was 251,000, 2,600, 142 and 92 heads per year and the generation amounts of annually carcass was 0.46, 15.32, 0.36, 1.36 tons per year of each poultry, swine, beef cow and dairy cow farms, respectively. The disposal methods of carcass were burying (42%), carcass dumping to manure pile (36%), rendering (8%), incineration (6%), digesting (6%), carcass disposer (2%), respectively. These results can be used as basic information to establish the standard of carcass composting facility.

Study on Probabilistic Analysis for Fire·Explosion Accidents of LPG Vaporizer with Jet Fire (Jet Fire를 수반한 국내외 LPG 기화기의 화재·폭발사고에 관한 확률론적 분석에 관한 연구)

  • Ko, Jae-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.31-41
    • /
    • 2012
  • This study collected 5,100 cases of gas accident occurred in Korea for 14 years from 1995 to 2008, established Database and based on it, analyzed them by detailed forms and reasons. As the result of analyzing the whole city gas accidents with Poisson analysis, the item of "Careless work-Explosion-Pipeline' showed the highest rate of accidents for the next 5 years. And, "Joint Losening and corrosion-Release-Pipeline" showed the lowest rate of accident. In addition, for the result of analyzing only accidents related to LPG vaporizer, "LPG-Vaporizer-Fire" showed the highest rate of accident and "LPG-Vaporizer-Products Faults" showed the lowest rate of accident. Also, as the result of comparing and analyzing foreign LPG accident accompanied by Jet fire, facility's defect which is liquid outflow cut-off device and heat exchanger's defect were analyzed as the main reason causing jet fire, like the case of Korea, but the number of accidents for the next 5 years was the highest in "LPG-Mechanical-Jet fire" and "LPG-Mechanical-Vapor Cloud" showed the highest rate of accidents. By grafting Poisson distribution theory onto gas accident expecting program of the future, it's expected to suggest consistent standard and be used as the scale which can be used in actual field.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

The Research on Job Analysis of Horse-Riding Instructor (승마지도사에 관한 직무분석 연구)

  • Lee, Byung-Wook;Kang, Kyoung-Kyoon;Yi, Joo-Wook;Lee, In-Kyung
    • Journal of vocational education research
    • /
    • v.33 no.3
    • /
    • pp.145-167
    • /
    • 2014
  • The purpose of this research is to prepare the measures for evaluating the job of horse-riding instructor and improvement related to it and for distributing horse-riding industry effectively. Forsuch, we tried to analyze job of horse-riding instructor. Inparticular, we have developed DACUM chart of horse-riding instructor through DACUM method and experts related to it. As result, we found out eight duties and hundreds of job and arranged seven duty areas in total and eighty-two executed works. In addition, as experts said, the horse-riding instructor is the one who 'instructs people learning horse-riding in horse-riding facility and manages horses, horse-riding equipment and man-power.' Such results provide the procedure of horse-riding instructor cultivation which has been presently underway with many viewpoints. Especially, there are three educational processes and subject materials related to horse-riding instructor's examination(Hipologia, Horse-treatment technique, Horse Health management). However, as result of analysis on duty, we found out that racecourse management and horse-riding education theory has been needed to be added and complemented as well. In addition, the work and duty of analysis can be used to be made use up of as work profile and specification and such data can be also made use of as standard of training and submission. Through this study there should be a necessary work to distinguish between re-drafting and role of duty in its own right related to certification of horse-riding instructor in future and it would be necessary to develop study that is able to connect them all to certificate. What is more, there should be work and measure required for rethinking of utility of certification.

A Study on Development of Mobile LNG Yard Tractor Refueling Standards (이동식 LNG 야드트랙터 충전 기준 개발 연구)

  • Ryou, Young-don;Yu, Chul-hee;Koo, Bon-deuk;Lee, Dong-won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.59-64
    • /
    • 2018
  • As part of measures to reduce fine dust, the government is promoting a project to convert the fuel of Yard Tractors(YT, tractors operated at ports), from diesel to LNG (Liquefied Natural Gas). While a port having a small number of yard tractors, it is not proper to construct a stationary LNG fueling station and supply LNG to YT due to a problem of BOG (Boil off gas) generation. Therefore, it is necessary to make a regulation and a standard on mobile LNG YT refueling station installation and inspection as an alternative. In this study, we have investigated domestic and foreign mobile LNG refueling cases and refueling standards, including the USA and Europe. In addition, we have suggested the risk reduction method according to the cause after investigation of the cause of LNG accidents. And last, based on the proposed risk reduction measures, we have proposed an amendment to the Regulation of the Urban Gas Business Law in Korea. The proposed mobile LNG YT refueling amendment of the Regulation includes ; maintenance of the safety distance from the protection facility, installation of an interlock device to prevent refueling in places other than the authorized place, installation of the identification system through biometrics, separation of the tank lorry and tow vehicle before refueling, checking the wheel fixed status of tank lorry before refueling, construction of the impounding area, safety measures before, during and after refueling, etc. The safety standards proposed in this study could be used as a reference in establishing standards for mobile LNG vehicle refueling in the near future.

Numerical Modeling for Effect on Bund Overtopping Caused by a Catastrophic Failure of Chemical Storage Tanks (저장시설의 순간 전량 방출 시 방류벽의 월파 효과에 대한 수치모델링)

  • Min, Dong Seok;Phark, Chuntak;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.42-50
    • /
    • 2019
  • As the industry develops in Korea, the use of hazardous chemicals is increasing rapidly and chemical accidents are increasing accordingly. Most of the chemical accidents are caused by leaks of hazardous chemicals, but there are also accidents in which all the substances are released instantaneously due to sudden high temperature/pressure or defection of the storage tanks. This is called catastrophic failure and its frequency is very low, but consequence is very huge when it occurs. In Korea, there were 15 casualties including three deaths due to catastrophic rupture of water tank in 2013, and 64 instances of failures from 1919 to 2004 worldwide. In case of catastrophic failure, it would be able to overflow outside the bund that reduces the evaporation rate and following consequence. This incident is called overtopping. Overseas, some researchers have been studying the amount of external overflow depending on bund conditions in the event of such an accident. Based on the previous research, this study identified overtopping fraction by condition of bund in accordance with Korea Chemicals Controls Act Using CFD simulation. As a result, as the height increases and the distance to the facility decreases while meeting the minimum standard of the bund capacity, the overtopping effect has decreased. In addition, by identifying the effects of overtopping according to atmospheric conditions, types of materials and shapes of bunds, this study proposes the design of the bund considering the effect of overtopping caused by catastrophic failure with different bund conditions.

The Study on the Fire Monitoring Dystem for Full-scale Surveillance and Video Tracking (전방위 감시와 영상추적이 가능한 화재감시시스템에 관한 연구)

  • Baek, Dong-hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.40-45
    • /
    • 2018
  • The omnidirectional surveillance camera uses the object detection algorithm to level the object by unit so that broadband surveillance can be performed using a fisheye lens and then, it was a field experiment with a system composed of an omnidirectional surveillance camera and a tracking (PTZ) camera. The omnidirectional surveillance camera accurately detects the moving object, displays the squarely, and tracks it in close cooperation with the tracking camera. In the field test of flame detection and temperature of the sensing camera, when the flame is detected during the auto scan, the detection camera stops and the temperature is displayed by moving the corresponding spot part to the central part of the screen. It is also possible to measure the distance of the flame from the distance of 1.5 km, which exceeds the standard of calorific value of 1 km 2,340 kcal. In the performance test of detecting the flame along the distance, it is possible to be 1.5 km in width exceeding $56cm{\times}90cm$ at a distance of 1km, and so it is also adaptable to forest fire. The system is expected to be very useful for safety such as prevention of intrinsic or surrounding fire and intrusion monitoring if it is installed in a petroleum gas storage facility or a storing place for oil in the future.