• Title/Summary/Keyword: Standard facility

Search Result 926, Processing Time 0.025 seconds

Developement of a Design Manual for Kitchen Facility in Foodservice Outlets: A Case Study on a Seolleongtang Specialized Restaurant (푸드서비스시설의 주방 설비 산정 매뉴얼 개발: 설렁탕 전문 식당 사례 적용)

  • Choi, Gyeong-Gy;Chang, Hye-Ja
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.67-77
    • /
    • 2021
  • Concerns regarding work and food safety in foodservice operations are growing. The purpose of the study is to suggest guidelines for designing foodservice facilities, including school foodservices and Korean restaurants. A case of a franchise restaurant specializing in a Korean food item, Seolleongtang, was used to explain the facility design. The contents of the manual included ways to determine space allocation, calculate the application of utilities and the diameters of supply utility pipelines, and suggestions on how to decide on air conditioning equipment. The standards of the American Gas Association and the Japan Foodservice Equipment Association (JFEA) were applied to design the restaurant space. The JFEA standards and knowledge based on experience and statistics were applied to calculate the usage of utilities like fuel and water. The standards of JFEA and the Society of Heating, Air-Conditioning, and Sanitary Engineers of Japan were applied to calculate the diameters of the water supply and drainage pipelines. For the setting of the heating, ventilation, and air conditioning systems, three ways to carry out the calculation of effective ventilation were explained, as well as options to dicide the standard parameters of the duct and ventilation fans. This manual can contribute to the design of effective and efficient foodservice facilities and help secure the work safety of foodservice employees thereby ensuring food safety.

Effects of Service Orientation on Pro-social behavior in the Care Facility for the Elderly (노인요양시설의 서비스지향성이 친사회적 행동에 미치는 영향)

  • Kwak, Eui-Soo;Kim, Gwan-Yong;Kim, Je-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.166-178
    • /
    • 2014
  • In this study, to know the influence of pro-social behavior by service orientation of care facility for the elderly, made a research from 80 care facility for the elderly of about 400 professor employees with visiting them and by the mail. survey was from 302 senior citizens by 61 facilities, and the final analysis was helped by 297 professor employees. First, as analysis from the standard of prime variable, it showed 3.84 of relatively high marked from the who have had aware of the level of pro-social behavior. overall, standard of service orientation shown 3.69 out of 5 which is also relatively high. Looking at the sub- dimensions of service-oriented leadership performance has shown 4.13 points out of 5, 3.78 points out of 5 on buildup the systems, management of human resource orientation shown 3.5 points out of 5 and attitude of services shown 3.36 points out of 5. In general, the service has showed up higher points on the overall. Second, by the analysis from the regression analysis, fulfillment of leadership (B=.004, P=.938), attitude of service (B=.031, P=.476), management of human resource (B=.147, P=.003), system build up (B=.175, P=.001) were made meaningfully influenced on pro-social behavior. Especially, the sub- dimensions of human resource management and the system buildup had a importantly major role for influencing on pro-social behavior. Based on this, in this study, care facility for the elderly professionals the ability to manage human resources programs and services to improve the efficiency of the system was proposed for building plans.

Development of Algorithm for Vibration Analysis Automation of Rotating Equipments Based on ISO 20816 (ISO 20816 기반 회전기기 진동분석 자동화 알고리즘 개발)

  • JaeWoong Lee;Ugiyeon Lee;Jeongseok Oh
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.93-104
    • /
    • 2024
  • Facility diagnosis is essential for the smooth operation and life extension of rotating equipment used in industrial sites. Compared to other diagnostic methods, vibration diagnosis can find most of the initial defects, such as unbalance, alignment failure, bearing defects and resonance, compared to other diagnostic methods. Therefore, vibration analysis is the most commonly used facility diagnosis method in industrial sites, and is usefully used as a predictive preservation (PdM) technology to manage the condition of the facility. However, since the vibration diagnosis method is performed based on experience based on the standard, it is carried out by experts. Therefore, it is intended to contribute to the reliability of the facility by establishing a system that anyone can easily judge defects by establishing a vibration diagnosis method performed based on experience as a knowledgeable code system. An algorithm was developed based on the ISO-20816 standard for vibration measurement, and the reliability was verified by comparing the results of vibration measurement at various demonstration sites such as petrochemical plant compressors, hydrogen charging stations, and industrial machinery with the results of analysis using a development system. The developed algorithm can contribute to predictive maintenance (PdM) technology that anyone can diagnose the condition of the rotating machine at industrial sites and identify defects early to replace parts at the exact time of replacement. Furthermore, it is expected that it will contribute to reducing maintenance costs and downtime due to the failure of rotating machines when applied to various industrial sites such as oil refining facilities, transportation, production facilities, and aviation facilities.

ON APPROXIMATIONS FOR GI/G/c RETRIAL QUEUES

  • Shin, Yang Woo;Moon, Dug Hee
    • Journal of applied mathematics & informatics
    • /
    • v.31 no.1_2
    • /
    • pp.311-325
    • /
    • 2013
  • The effects of the moments of the interarrival time and service time on the system performance measures such as blocking probability, mean and standard deviation of the number of customers in service facility and orbit are numerically investigated. The results reveal the performance measures are more sensitive with respect to the interarrival time than the service time. Approximation for $GI/G/c$ retrial queues using $PH/PH/c$ retrial queue is presented.

The Property Analysis of Float Type Water-Level Gauges used the Standard Test Facility of Water-Level Gauges (수위계 표준 시험 장치를 이용한 부자식 수위계 특성 분석)

  • Shin, Gang-Wook;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.194-196
    • /
    • 2007
  • 댐 및 저수지 운영시 가장 중요한 센서 중의 하나인 수위계는 댐의 수문조작에 있어 직접적으로 연관되기 때문에 수위계의 특성이 잘 관리될 필요가 있다. 따라서 수위 측정에 널리 사용되고 있는 부자식, 초음파식, 그리고 레이다식 수위계에 대한 특성시험이 가능하도록 수위계 표준 시험 장치를 개발하였고, 이를 이용하여 레이다식 수위계와 초음파식 수위계에 대하여 수위에 따른 특성시험을 실시하여 각 수위계에 대한 특성을 상호 비교 분석하고자 한다.

  • PDF

A Study on the Identification of Phenol Production by GC/MS under Chemical Treatment of Industrial Wastewater (화학적 폐수처리 중 GC/MS에 의한 폐놀생성 규명에 관한 연구)

  • 박선구;고오석;신대윤
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.89-93
    • /
    • 2000
  • Twenty organic chemical substances(Table 2) were isolated from untreated wastewater, as well as treated wastewater, collected at 76 companys of 9 industry group located in the basin of Youngsan River. Those organic compounds were analyzed by Gas Chromatography/Mass Spectrometry(GC/MS) and confirmed through comparison with each standard reagents. Phenol, which was not detected in the raw wastewater, was identified in the effluent of treatment facility, indicating that phenol is generated from isopropylbenzene of plant wastewater.

  • PDF

The Property Analysis of Water-Level Gauges used the Standard Test Facility of Water-Level Gauges (수위계 표준시험장치를 이용한 수위계 특성 분석)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.281-282
    • /
    • 2007
  • 댐 및 저수지 운영시 가장 중요한 센서 중의 하나인 수위계는 댐의 수문조작에 있어 직접적으로 연관되기 때문에 수위계의 특성이 잘 관리될 필요가 있다. 따라서 수위 측정에 널리 사용되고 있는 부자식, 초음파식, 그리고 레이다식 수위계에 대한 특성시험이 가능하도록 수위계 표준 시험장치를 개발하였고, 이를 이용하여 레이다식 수위계와 초음파식 수위계에 대하여 수위에 따른 특성시험을 실시하여 각 수위계에 대한 특성을 상호 비교 분석하고자 한다.

  • PDF

The Property Analysis by horizontality Control for the Standard Test Facility of Water-Level Gauges (수위계 표준시험장치의 수평제어에 따른 특성분석)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.279-280
    • /
    • 2007
  • 수위계 표준시험장치 초기 구축시 수직 20 m를 오르내리는 리프트에 있어서 수직 상승시 리프트가 상시 수평을 유지하는 기능이 없었기 때문에 보정값이 커지는 요인으로 작용하였다. 따라서 장치의 개선을 통하여 수평을 유지할수 있도록 스테핑모터를 이용하여 시스템을 보완하였으며, 기존의 수평제어를 하지 않았던 데이터와 스테핑모터를 이용하여 제어된 데이터를 비교하여 상호간의 성능 분석 및 수평 데이터가 보정값에 미치는 영향을 분석하고자 한다.

  • PDF

Assessment of the Working Environment and Development of the Space Requirement and Facility Standard Models for the Various Types of Restaurants in Seoul City Area (서울시내 요식업소의 작업환경 실태조사 및 그 개선을 위한 모델 제시)

  • 곽동경
    • Journal of Nutrition and Health
    • /
    • v.19 no.6
    • /
    • pp.392-401
    • /
    • 1986
  • Various types of restaurants in Seoul city are a were assessed in terms of facilities equipped, and dining and kitchen space allocation. Facilities checklist was developed to evaluate the facilities condition of sampled restaurants. Subjective sample were randomly selected based on the distribution factors of areas, types and sizes. The facilities for the sanitary working environment were assessed as the insufficient condition. Also basic kitchen equipments and facilities, and restroom facitilities of restaurants were within the kitchen or dining room space allowance level. Space requirement and facilities standard models were developed for the guideline to improve the working environment.

  • PDF

A Survey on Enterence Dose by Exposure Factors (X-선촬영 조건에 따른 피폭선량 조사연구)

  • Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.19-25
    • /
    • 1998
  • By analyzing each part of expsure condition and the status of an entrance dose which is exposed to patients, this study reached the following conclusion. Since there is no standard in setting up an exposure condition, the technology practiced in each facility varies tremendously, and the entrance dose increased especially due to the improper selection of screen and grid and the shortage of a total amount of filtration in leaching the standard filtration amount. Entrance dose was, generally, turned out to be $2{\sim}3$ times as much as that of advanced countries, and there was big difference between facilities ; approximately 52 times inlateral of cervical vertebrae, 35 times in A-P of femur, 33 times in chest A-P, and 11 times in lumber A-P. Therefore, to minimize the entrance dose of a patient with thegreatest amount of image information, acquirement of technological know-how necessary for standardization of exposure condition for each part can be an important research task.

  • PDF