• Title/Summary/Keyword: Standard dome

Search Result 29, Processing Time 0.03 seconds

Development and Validation of Sky Simulator for Reproducing CIE Overcast Sky Model (돔형 인공천공의 개발 및 CIE표준담천공 구현 검증에 관한 연구)

  • Shin, Ju Young;Yun, Geun Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.97-103
    • /
    • 2010
  • Sky simulator is a effective daylighting design tool that can evaluate three dimensional performance of lighting. Especially, the dome type sky simulator offer reliable and reproducible daylighting performance with different standard sky models. Recently, K university has developed the dome type sky simulator(sky dome) with the diameter of 6.5m and the height of 3.7m. The sky dome consists of a group of 145 large steel panels with 72 halogen lamps which are arranged in a circular array. The luminance distribution of the sky dome can be calibrated by changing the angle and the brightness of the lamps respectively. To allow more reliable prediction and evaluation of daylighting through the sky dome, It is essential to validate the sky luminance distribution of the sky dome. This study consider the validation of the comparisons between the measured and the calculated luminance values for the CIE standard overcast sky. Also, the error rate between the measured and the calculated luminance values were compared to the previous studies. The results indicated that the K university sky dome can reproduce reliable CIE standard overcast sky with the average relative error rate of 4.4% and root-mean-square error(RMSE) of 5.4%.

An Arrangement Technique for Fine Regular Triangle Grid of Network Dome by Using Harmony Search Algorithm (화음탐색 알고리즘을 이용한 네트워크 돔의 정삼각형 격자 조절기법)

  • Shon, Su-Deok;Jo, Hye-Won;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2015
  • This paper aimed at modeling a fine triangular grid for network dome by using Harmony Search (HS) algorithm. For this purpose, an optimization process to find a fine regular triangular mesh on the curved surface was proposed and the analysis program was developed. An objective function was consist of areas and edge's length of each triangular and its standard deviations, and design variables were subject to the upper and lower boundary which was calculated on the nodal connectivity. Triangular network dome model, which was initially consist of randomly irregular triangular mesh, was selected for the target example and the numerical result was analyzed in accordance with the HS parameters. From the analysis results of adopted model, the fitness function has been converged and the optimized triangular grid could be obtained from the initially distorted network dome example.

Analysis of External Peak Pressure Coefficients for Cladding in Elliptical Retractable Dome Roof by Wind Tunnel Test (풍동 실험을 통한 타원형 개폐식 돔 지붕의 외장재용 풍압 계수 분석)

  • Lee, Jong-Ho;Kim, Yong-Chul;Cheon, Dong-Jin;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 2020
  • This study investigates the wind pressure characteristics of elliptical plan retractable dome roof. Wind tunnel experiments were performed on spherical dome roofs with varying wall height-span ratios (0.1~0.5) and opening ratios (0%, 10%, 30% and 50%), similar to previous studies of cirular dome roofs. In previous study, wind pressure coefficients for open dome roofs have been proposed since there are no wind load criteria for open roofs. However, in the case of Eeliptical plan retractable dome roof, the wind pressure coefficient may be largely different due to the presence of the longitudinal direction and transverse direction. The analysis results leads to the exceeding of maximum and minimum wind pressure coefficients KBC2016 code.

A Study on the Dome Plan of S. M. del Fiore Church of F. Brunelleschi (브루넬레스키의 산타 마리아 델 휘오레 교회의 돔계획에 관한 연구)

  • Kim, Seok-Man
    • Journal of architectural history
    • /
    • v.21 no.5
    • /
    • pp.19-32
    • /
    • 2012
  • The purpose of this paper is a study on the dome plan of S. M. del Fiore Church of F. Brunelleschi. The results of study are as follows: 1. The planning of floor, elevation and cross section plan of S. M. del Fiore church is basically planned by each other correlation. In particular, the octangular form of geometrical standard which is formed with altar as the center at the crossing part is important component elements which is decided by not only the dome, but form and size of the drum and floor plan form of the lantern 2. The dome which has been planned by F. Brunelleshi has completed the new dome, preserving gothic thought intended by the church plan after study on architecture of ancient Rome with Pantheon. And the dome which is a main space of church through all aspects of plan, structure, function and construction about the dome is a opportunity in the beginning of Renaissance architecture which is a new epoch and a turning point of architecture on various point of view. 3. The dome which is constructed by F. Brunelleshi has been planned through the innovative solution by the refusal of traditional semicircle form dome, centering use and creation double-shell structure form for the first time in history. And the construction of dome has been solved with the invention of various construction equipments and machineries, the stone rib planned for connection and reinforcement about shells of the octangular form, the support method for reduction the gravity of bricklayers work and the brick work of nock-patterned shape which is masonry construction method of the architecture of ancient Rome.

Comparison of Wind Pressure Coefficient and Wind Load Standard for Cladding in a Retractable Dome Roof by Wind Tunnel Test (풍동 실험을 통한 개폐식 돔 지붕의 외장재용 풍압 계수와 풍하중 기준 비교)

  • Cheon, Dong-jin;Kim, Yong-Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.

Consideration on the Thickness of the Gas Introducing Tube of the Test Dome Specified in the ISO Standard (ISO 규격에서 규정한 표준용기 기체도입 도관의 직경에 대한 고찰)

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.161-168
    • /
    • 2010
  • The ISO standard specifies the diameter of the gas introducing tube to be definitely 1/10 of the chamber inner diameter of the standard test dome which is used for evaluating the performance of vacuum pumps. Because the inner diameter of the test chamber should not be less than the intake diameter of the vacuum pump, the tube diameter would be even 100 mm if fitting to a very large vacuum pump. Though such a thick tube can be accommodated in a large test dome, it is worthful to investigate whether a thicker tube is helpful or adverse for making more accurate measurements. In this paper it is discussed if there is an optimum tube diameter by comparing the isotropicity of particles emanating from the tube and that of particles entering the orifice.

WINDSCREEN INSTALLED AT THE BOAO 1.8M TELESCOPE DOME (보현산천문대 1.8m 망원경 돔의 방풍막 설치)

  • KIM SEUNG-LEE;SEONG HYEON-CHEOL;YUK IN-SOO;NOH JIN-HYUNG
    • Publications of The Korean Astronomical Society
    • /
    • v.13 no.1 s.14
    • /
    • pp.65-73
    • /
    • 1998
  • We installed windscreen at the BOAO 1.8m telescope dome, in order to reduce the degradation of image Quality under strong wind larger than 8m/sec. The windscreen was designed on the basis of that installed at the MSSSO 2.3m telescope dome in Australia. We developed control system (remote control and user program) of the windscreen, being able to operate the windscreen at observation room. We tested the performance of the windscreen under strong wind of 6-15m/see. Tracking error of the telescope, especially in altitude-axis, was greatly decreased when the windscreen was used. Standard deviation of the error was estimated to be less than 0.3arcsec, which has little effect on image quality.

  • PDF

A Comparative Study of Genetic Algorithm and Mathematical Programming Technique applied in Design Optimization of Geodesic Dome (지오데식 돔의 설계최적화에서 유전알고리즘과 수학적계획법의 비교연구)

  • Lee, Sang-Jin;Lee, Hyeon-Jin
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.101-106
    • /
    • 2008
  • This paper describes a comparative study of genetic algorithm and mathematical programming technique applied in the design optimization of geodesic dome. In particular, the genetic algorithm adopted in this study uses the so-called re-birthing technique together with the standard GA operations such as fitness, selection, crossover and mutation to accelerate the searching process. The finite difference method is used to calculate the design sensitivity required in mathematical programming techniques and three different techniques such as sequential linear programming (SLP), sequential quadratic programming(SQP) and modified feasible direction method(MFDM) are consistently used in the design optimization of geodesic dome. The optimum member sizes of geodesic dome against several external loads is evaluated by the codes $ISADO-GA{\alpha}$ and ISADO-OPT. From a numerical example, we found that both optimization techniques such as GA and mathematical programming technique are very effective to calculate the optimum member sizes of three dimensional discrete structures and it can provide a very useful information on the existing structural system and it also has a great potential to produce new structural system for large spatial structures.

  • PDF

Axisymmetric Modeling of Dome Tendons in Nuclear Containment Building I. Theoretical Derivations (원전 격납건물 돔 텐던의 축대칭 모델링 기법 I. 이론식의 유도)

  • Jeon Se-Jin;Chung Chul-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.521-526
    • /
    • 2005
  • Prestressing tendons in a nuclear containment building dome are non-axisymmetrically arranged in most cases. However, simple axisymmetric modeling of the containment has been often employed in practice to estimate structural behavior for the axisymmetric loadings such as an internal pressure. In this case, the axisymmetric approximation is required for the actual tendon arrangements in the dome. Some procedures are proposed that can implement the actual 3-dimensional tendon stiffness and prestressing effect into the axisymmetric model. Prestressing tendons, which are arranged in 3 or 2-ways depending on a containment type, are converted into an equivalent layer to consider the stiffness contribution in meridional and hoop directions. In order to reflect the prestressing effect, equivalent load method and initial stress method are devised and the corresponding loads or stresses are derived in terms of the axisymmetric model. In a companion paper, the proposed schemes are applied into CANDU and KSNP(Korean Standard Nuclear Power Plant) type containments and are verified through some numerical examples comparing the analysis results with those of the actual 3-dimensional model.

A CASE REPORT OF MUCOID RETENTION CYST IN MAXILLARY SINUS. (상악동 점액저유낭종의 일례)

  • Kim Han Pyoung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.3 no.1
    • /
    • pp.47-49
    • /
    • 1973
  • The author have observed mucoid retention cyst in the right maxillary sinus of the patient, 41 years old woman, complained discharging of purulent exudate on the right maxillary molar teeth area, and obtained the following conclusions; 1. The mucoid retention cyst in maxillary sinus casts a faint dome shaped shadow into the radiolucent image of maxillary sinus. 2. The mucoid retention cyst in maxillary sinus may be occured without a history of trauma. 3. Intraoral standard films are also valuable for the interpretation of the lesions in maxillary sinus but only extraoral roentgenograms.

  • PDF