• Title/Summary/Keyword: Standard Operation Time

Search Result 653, Processing Time 0.043 seconds

MPEG-H 3D Audio Decoder Structure and Complexity Analysis (MPEG-H 3D 오디오 표준 복호화기 구조 및 연산량 분석)

  • Moon, Hyeongi;Park, Young-cheol;Lee, Yong Ju;Whang, Young-soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.2
    • /
    • pp.432-443
    • /
    • 2017
  • The primary goal of the MPEG-H 3D Audio standard is to provide immersive audio environments for high-resolution broadcasting services such as UHDTV. This standard incorporates a wide range of technologies such as encoding/decoding technology for multi-channel/object/scene-based signal, rendering technology for providing 3D audio in various playback environments, and post-processing technology. The reference software decoder of this standard is a structure combining several modules and can operate in various modes. Each module is composed of independent executable files and executed sequentially, real time decoding is impossible. In this paper, we make DLL library of the core decoder, format converter, object renderer, and binaural renderer of the standard and integrate them to enable frame-based decoding. In addition, by measuring the computation complexity of each mode of the MPEG-H 3D-Audio decoder, this paper also provides a reference for selecting the appropriate decoding mode for various hardware platforms. As a result of the computational complexity measurement, the low complexity profiles included in Korean broadcasting standard has a computation complexity of 2.8 times to 12.4 times that of the QMF synthesis operation in case of rendering as a channel signals, and it has a computation complexity of 4.1 times to 15.3 times of the QMF synthesis operation in case of rendering as a binaural signals.

An Analysis of Efficiency in Major University Hospitals in Domestically Capital Area Through DEA Analysis (DEA분석을 통한 국내 수도권 주요 대학병원의 효율성 분석)

  • Park, Byeong-Tae;Lee, Dong-Hyeon
    • Korea Journal of Hospital Management
    • /
    • v.16 no.4
    • /
    • pp.35-66
    • /
    • 2011
  • This study analyzed efficiency by utilizing DEA analytical technique centering on materials for 2009 of 20 major university hospitals in capital area. Input variables were utilized professor & full-time doctor, resident, nurse & number of bed hospitals. Output variables were analyzed by dividing number of annual outpatients & number of annual inpatients, and annually total outpatient profit & inpatient profit into a model of the standard for number of patients and the standard for medical profit. DEA analysis was elicited efficiency score by applying CCR, BCC, BFG, scale profit, and SE model. Through t-test after eliciting efficiency score, the implications were suggested by comparing efficiency between DMU in Seoul and DMU in capital area, by comparing between high-class general hospitals and general hospitals, and by comparing between high-class general hospitals in Seoul and 5 big hospitals. As a result of analysis, the major university hospitals in capital area showed high efficiency as a whole close to "1," but indicated low efficiency relatively in CCR field. Thus, the expansion in scale within capital area was indicated to reach the limit. Second, in a model of analyzing the standard for number of patients, the medical institutions, which are being operated efficiently, were indicated to be 10 DMUs. In the standard for medical profit, 12 DMUs were analyzed to be operated efficiently. Third, the efficiency in general hospital was higher than high-class general hospital. Thus, the efficiency of operation was indicated to be more important than scale. Also, large high-class hospitals(big 5) where are located in downtown Seoul showed the higher efficiency than other general high-class general hospitals, but were indicating very low efficiency in some DMUs. Fourth, as a result of generalizing and evaluating the number of patients and the medical profit, the efficient DMU was indicated to be more when analyzing on the basis of medical profit than the standard for number of patients. Thus, major university hospitals in capital area were indicated to make more effort for section in medical profit. Based on the analytical results of efficiency, a strategy for reinforcing efficiency in inefficient DMU was indicated to be needed a strategy of creating customers for promoting number of patients and a strategy for making operation efficient for increasing profitability.

  • PDF

An Intra Prediction Hardware Design for High Performance HEVC Encoder (고성능 HEVC 부호기를 위한 화면내 예측 하드웨어 설계)

  • Park, Seung-yong;Guard, Kanda;Ryoo, Kwang-ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.875-878
    • /
    • 2015
  • In this paper, we propose an intra prediction hardware architecture with less processing time, computations and reduced hardware area for a high performance HEVC encoder. The proposed intra prediction hardware architecture uses common operation units to reduce computational complexity and uses $4{\times}4$ block unit to reduce hardware area. In order to reduce operation time, common operation unit uses one operation unit to generate predicted pixels and filtered pixels in all prediction modes. Intra prediction hardware architecture introduces the $4{\times}4$ PU design processing to reduce the hardware area and uses intemal registers to support $32{\times}32$ PU processmg. The proposed hardware architecture uses ten common operation units which can reduce execution cycles of intra prediction. The proposed Intra prediction hardware architecture is designed using Verilog HDL(Hardware Description Language), and has a total of 41.5k gates in TSMC $0.13{\mu}m$ CMOS standard cell library. At 150MHz, it can support 4K UHD video encoding at 30fps in real time, and operates at a maximum of 200MHz.

  • PDF

Rapid Prototyping from Reverse Engineered Geometric Data (리버스 엔지니어링으로 생성된 데이터를 이용한 쾌속 조형 기술 연구)

  • Woo, Hyuck-Je;Lee, Kwan-Heng
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.95-107
    • /
    • 1999
  • The design models of a new product in general are created using clay models or wooden mock-ups. The reverse engineering(RE) technology enables us to quickly create the CAD model of the new product by capturing the surface of the model using laser digitizers or coordinate measuring machines. Rapid prototyping (RP) is another technology that can reduce the product development time by fabricating the physical prototype of a part using a layered manufacturing technique. In reverse engineering process, however, the digitizer generates an enormous amount of point data, and it is time consuming and also inefficient to create surfaces out of these data. In addition, the surfacing operation takes a great deal of time and skill and becomes a bottleneck. In rapid prototyping, a faceted model called STL file has been the industry standard for providing the CAD input to RP machines. It approximates the CAD model of a part using many planar triangular patches and has drawbacks. A novel procedure that overcomes these problems and integrates RE with RP is proposed. Algorithms that drastically reduce the point clouds data have been developed. These methods will facilitate the use of reverse engineered geometric data for rapid prototyping, and thereby will contribute in reducing the product development time.

  • PDF

AN APPLICATION OF INTERPOLATION TECHNIQUE WITH OPTIMUM PATTERN TO VOLTAGE - REACTIVE POWER CONTROL OF POWER SYSTEM (전력계통 전압 - 무효전력제어에의 최적 패턴을 이용한 내삽기법의 적용)

  • Park, Young-Moon;Lee, Jeong-Ho;Yoon, Man-Chul;Kwon, Tae-Won
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.214-217
    • /
    • 1992
  • This paper introduces a new methodology to apply the interpolation technique wi th optimum pattern to voltage-reactive power control of power system. The conventional tool for the optimal operation of power system is Optimal Power Flow(OPF) by standard optimization techniques. The achievement of solution through OPF programs has a defect of computation time, so that it is impossible to apply the OPF programs to the real-time control area. The proposed method presents a solution in a short period of time and an output with a good accuracy. The optimum pattern is a set of input-output pairs, where an input is a load level and a type of outage and an output is the result of OPF program corresponding to the input. The output in the OPF represents control variables of voltage-reactive power control. The interpolation technique is used to obtain the solution for an arbitrary input. As a result, the new technique helps operators in the process of the real-time voltage-reactive power control in both normal and emergency operating states.

  • PDF

Faster-than-real-time Hybrid Automotive Underwater Glider Simulation for Ocean Mapping

  • Choi, Woen-Sug;Bingham, Brian;Camilli, Richard
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.3
    • /
    • pp.441-450
    • /
    • 2022
  • The introduction of autonomous underwater gliders (AUGs) specifically addresses the reduction of operational costs that were previously prohibited with conventional autonomous underwater vehicles (AUVs) using a "scaling-down" design philosophy by utilizing the characteristics of autonomous drifters to far extend operation duration and coverage. Long-duration, wide-area missions raise the cost and complexity of in-water testing for novel approaches to autonomous mission planning. As a result, a simulator that supports the rapid design, development, and testing of autonomy solutions across a wide range using software-in-the-loop simulation at faster-than-real-time speeds becomes critical. This paper describes a faster-than-real-time AUG simulator that can support high-resolution bathymetry for a wide variety of ocean environments, including ocean currents, various sensors, and vehicle dynamics. On top of the de facto standard ROS-Gazebo framework and open-sourced underwater vehicle simulation packages, features specific to AUGs for ocean mapping are developed. For vehicle dynamics, the next-generation hybrid autonomous underwater gliders (Hybrid-AUGs) operate with both the buoyancy engine and the thrusters to improve navigation for bathymetry mappings, e.g., line trajectory, are is implemented since because it can also describe conventional AUGs without the thrusters. The simulation results are validated with experiments while operating at 120 times faster than the real-time.

Advanced Treatment of Liquid Fertilizer from Livestock Night Soil Treatment Facility by Membrane Separation Processes (분리막 공정을 이용한 축산분뇨 처리장 액비의 고도처리)

  • Kim, Joo-Hye;Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.142-150
    • /
    • 2014
  • This paper is to develop the process suitable for the advanced treatment of liquid fertilizer from the livestock night soil treatment facility (biogas plant). Nanofiltration (NF) and reverse osmosis (RO) process was used, respectively, for the advanced treatment of liquid fertilizer. And membrane bioreactor (MBR) with and without biomedia were tested, respectively, for the pretreatment. It was found that almost T-N of the liquid fertilizer was composed of ammoniacal nitrogen. Transmembrane pressure of MBR with biomedia increased slowly during the operation time, while that of MBR without biomedia increased rapidly at the initial time. But there was no difference observed in the removal efficiencies of COD, T-N, and T-P irrespective of the dosage of biomedia. When the liquid fertilizer was pretreated by MBR with biomedia, the removal efficiencies of COD, T-N, and T-P were 99.8, 86.5%, and 99.8% by NF, and 99.9, 86.8%, and 99.8% by RO, respectively. Compared with the effluent quality standards of the livestock night soil treatment facility, the water quality treated by MBR and NF/RO process met the standard for COD and T-P, but exceeded the permitted standard for T-N. In order to meet the effluent quality standard for T-N, it is necessary to change the MBR operation cycle or to add the secondary treatment by NF/RO.

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

Effects of HACCP Implementation on an Industry Foodservice Operation in Daegu (대구지역 사업체급식소에 대한 HACCP 적용 효과)

  • 남은정;김미라;이연경
    • Journal of Nutrition and Health
    • /
    • v.36 no.2
    • /
    • pp.223-230
    • /
    • 2003
  • The purpose of this study was to evaluate the effects of HACCP implementation. The HACCP education was provided twice within one month to 20 employees of a contracted food service operation in Daegu. Critical control points (CCP) were determined based on food preparation processes: non-heating, preparation after heating, and heating. We evaluated the effects of HACCP implementation by checking microbiological quality, time and temperature at each of the CCPs during the receiving, preparation, cooking, and serving stages. After HACCP implementation, the biggest changes in microbiological qualities were in heated foods. At the cooking and serving stages, the microbiological qualities of heated foods improved to the standard levels. HACCP education helped employees ensure that the internal temperatures of the heated foods were kept higher than the standard (74 $^{\circ}C$) and the food holding temperature avoided the dangerous zone (5-6$0^{\circ}C$), thus lowering microbiological levels. At the serving stage, the microbiological levels of utensils also improved after HACCP education. This result strongly suggests that it is essential to educate employees in managing the temperature to treat foods safely. However, HACCP education didn't affect the microbiological levels of non-heated foods and foods prepared after heating, which continued to be higher than the standard. The reason for this was that poor microbiological quality seasonings were added to those types of foods. This indicates that seasoning factories as well as food service operations should implement HACCP to reduce hazards.

Removal of High Concentration Manganese in 2-stage Manganese Sand Filtration (2단 망간모래여과에 의한 고농도 망간 처리)

  • Kim, Chung H.;Yun, Jong S.;Lim, Jae L.;Kim, Seong S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.503-508
    • /
    • 2007
  • Small scale D-water treatment plant(WTP) where has slow sand filtration was using raw water containing high concentration of manganese (> 2mg/l). The raw water was pre-chlorinated for oxidation of manganese and resulted in difficulty for filtration. Thus, sometimes manganese concentration and turbidity were over the water quality standard. Two stage rapid manganese sand filtration pilot plant which can treat $200m^3/d$ was operated to solve manganese problem in D-WTP. The removal rate of manganese and turbidity were about 38% and 84%, respectively without pH control of raw water. However, when pH of raw water was controlled to average 7.9 with NaOH solution, the removal rate of manganese and turbidity increased to 95.0% and 95.5%, respectively and the water quality of filtrate satisfied the water quality standard. Manganese content in sand was over 0.3mg/g which is Japan Water Association Guideline. The content in upper filter was 5~10 times more than that of middle and lower during an early operation but the content in middle and lower filter was increased more and more with increase of operation time. This result means that the oxidized manganese was adsorbed well in sand. Rapid manganese sand filter was backwashed periodically. The water quality of backwash wastewater was improved by sedimentation. Thus, turbidity and manganese concentration decreased from 29.4NTU to 3.09NTU and from 1.7mg/L to 0.26mg/L, respectively for one day. In Jar test of backwash wastewater with PAC(Poly-aluminum chloride), optimum dosage was 30mg/L. Because the turbidity of filtrate was high as 0.76NTU for early 5 minute after backwash, filter-to-waste should be used after backwash to prevent poor quality water.