Analysis on the Vibration Transmission Characteristics of the Standard Test Building by Using Standard Impact Source (경량 및 중량 충격원에 의한 표준 실험동의 진동전달 특성 분석)

  • Jin, Pil-Hwa;Kim, Heung-Sik;Kim, Do-Heong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.371-371
    • /
    • 2006
  • The purpose of this study is to provide a fundamental data for efficient and economical reduction method and predict ion method of floor impact noise. In order to get the useful results, the measurement on the vibration transmission characteristics of standard test building with four rooms by using heavy and light-weighed impact source were carried out. In this measurement various conditions such as the change of test structure construction, the pick-up sensor location, the excitation posit ion, and the resilient material types were applied to get the vibration characteristics transmitted from excitation room to adjacent rooms.

  • PDF

A Study on the Corrosion Resistance Test of Smoke Detectors (연기감지기의 내식시험에 관한 연구)

  • Kim, Hyeong-Gweon;Yoon, Hun-Ju;Kwon, Seong-Pil;SaKong, Seong-Ho;Back, Chang-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.155-158
    • /
    • 2008
  • In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.

  • PDF

A Study on the Methods of the Overhead Standard Setting and the Overhead Variance Analysis in Standard Cost Accounting (표준원가계산에 있어서 제조간접비표준의 설정과 차이분석기법)

  • 김선정
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.6 no.8
    • /
    • pp.81-91
    • /
    • 1983
  • In this study the methods of the overhead standard setting and the overhead variance analysis, which raise problems especially in business practice in case that small businesses introduce the standard cost accounting system, were examined by hypothetical examples. As the result of this study small businesses are advised to take the following in setting the overhead cost. (1) To divide the mixed cost into variable overhead and fixed overhead, it is desirable to take Beast square method. (2) In setting the overhead standard, it is desirable to fake the flexible budget system and to make a budget by the inspection method, after dividing the overhead into variable overhead and fixed overhead. (3) After dividing the overhead variance into variable overhead variance and fixed overhead variance, it is desirable to analyze them as follows. (A) Variable overhead variance is analyzed into spending variance and efficiency variance. (B) Fixed overhead valiance is analyzed into budget variance and denominator variance.

  • PDF

A study on Standard Safety Operation Evaluation Method for Improving Safety Activity (안전활동 개선을 위한 표준 안전작업 평가기법 설계)

  • Yang, Kwang-Mo;Yang, Hyun-Hoo;Kang, Yun-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.4
    • /
    • pp.39-47
    • /
    • 2007
  • An industrial injury prevention has a basis on fundamental spirit of human respect rather than only injury prevention in company. The employer should recognize employee as a core part of an industrial management and use as a starting point of safety and health management rather than means of production. There are many reason for unsafety action without safety operation. The reason is no standard safety operation in company or the workers never get a enough education. Standard safety operation is prepared by paper for accurate directions and orders and operators must read the paper to prevent an error of action. Also an essential particular is safety of equipment and machine must be assumed to establish standard safety operation then safety of operations will be possible.

Precise Determination of Silicon in Ceramic Reference Materials by Prompt Gamma Activation Analysis at JRR-3

  • Miura, Tsutomu;Matsue, Hideaki
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.299-303
    • /
    • 2016
  • Prompt gamma activation analysis using a thermal neutron-guided beam at Japan Atomic Energy Agency JRR-3M was applied for the precise determination of Si in silicon nitride ceramic reference materials [Japan Ceramic Reference Material (JCRM) R 003]. In this study, the standard addition method coupled with internal standard was used for the nondestructive determination of Si in the sample. Cadmium was used as internal standard to obtain the linear calibration curves and to compensate for the neutron beam variability. The analytical result of determining Si in JCRM R 003 silicon nitride fine powder ceramic reference materials using prompt gamma activation analysis was in good agreement with that obtained by classical gravimetric analysis. The relative expanded measurement uncertainty (k = 2) associated with the determined value was 2.4%.

The Structural Characteristics of Non-slip Device in Connecting Method Between Steel Pipe Pile and Footing (미끌림 방지턱을 이용한 강관말뚝 머리 결합부의 구조특성에 관한 실험적 연구)

  • 박영호;김낙영
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.227-243
    • /
    • 2003
  • To find the structural characteristics of non-slip device in connecting method B between steel pipe pile and concrete footing, compression and uplift test was performed for full sized specimens not having non-slip device, those having non-slip device with two curved steel plate bars welded inside the steel pipe pile(standard method), and those having non-slip device with serveral curved steel plate bars bolted inside the steel pipe pile(new method). As a result, specimens not having non-slip device had chemical debonding failure at 15.6tonf of peak uplift load and 27.57tonf of peak compression load. And the standard method and the new method showed about 8.9 times of peak uplift load and 6.2 times of peak compression load higher than specimens not having non-slip device. The load transfers of lower non-slip devices of the standard method and the new method were similar in behavior, while the higher non-slip device of the new method showed higher ratio of load transfer than that of the standard method. And these two methods had nearly the same composite action and structural capacity caused by non-slip devices.

Development of Enhanced Analytical Method for Perchlorate in Food by IC-MS/MS with an Internal Standard (IC-MS/MS와 내부표준물질을 이용한 식품 중 perchlorate 분석법 개선)

  • Yang, Min-June;Kim, Jong-Sung;Han, Jong-Hun;Her, Nam-Guk
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.532-536
    • /
    • 2011
  • The internal standard method using ion chromatography combined with tandem mass spectrometry (IC-MS/MS) for quantifying perchlorate in different types of food was established. Because the presence of ions and other biomolecules in matrices usually interrupts accurate determination of perchlorate, it is necessary to develop efficient, reproducible method to determine perchlorate concentrations in food. In this study, the internal standard method was compared with the external standard method to determine perchlorate concentrations in standard samples. The obtained method detection limit (MDL) for perchlorate was 0.005 ${\mu}g/L$ for bottled water, 0.12 ${\mu}g/L$ for milk, 0.27 ${\mu}g/kg$ for rice, 0.16 ${\mu}g/kg$ for vegetables, and 0.07 ${\mu}g/kg$ for seaweed, respectively. The limit of quantitation (LOQ) was calculated by multiplying the MDL by 7. The recoveries of perchlorate from food samples spiked with perchlorate ranged from 98 to 105% and their percent relative standard deviation (%RSD) levels were <20%. This method was successfully applied for the quantitative determination of perchlorate in various kinds of food.

A Study on the Development and the Uncertainty Analysis of Oil Flow Standard System (기름 유량표준장치의 개발 및 측정 불확도에 관한 연구)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1071-1080
    • /
    • 2003
  • A national standard system was developed in order to calibrate and test the oil flowmeters for the petroleum field. A stop valve and a gyroscopic weighing scale were employed for the primary standard of the flow quantity. It is operated by the standing start and finish mode and the static weighing method. The model equation for uncertainty evaluation was based on the calibration principle of standard system. The sources of the uncertainties were quantified and combined according to the GUM(Guide to the Expression of Uncertainty in Measurement). It was found that the standard system had the relative expanded uncertainty of 0.04 % in the range of 18 - 350 ㎥/h. According to the uncertainty budget, the uncertainties of the fluid density and the volume of pipeline, which were temperature dependent, contributed 92% of final uncertainty in the oil flow standard system.

Color Correction Method of Non-standard Display Using Standard Color Space (표준 색공간을 이용한 비표준 디스플레이의 색 보정 방법)

  • Kim, Eun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2151-2157
    • /
    • 2015
  • A standard default color space, sRGB, provides compatibility for the transmission of color within the Internet color operating systems and device drivers. However, a display monitor we use generally have non-standard primaries and gamma characteristic different from those specified by sRGB. In this paper, correction methods of chromatic error for a non-standard display monitor are proposed. Experimental results show that the proposed method using the correction matrix reduced chromatic errors at in compared with the non-corrected image's on a non-standard display.

Supplementation of Regulation on the Offshore Oil Pipeline for Maintenance (해저 송유배관 유지관리를 위한 기준 보완 제시)

  • Kang, Chan-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.8 no.2
    • /
    • pp.70-81
    • /
    • 2012
  • The study aims to supplement facility management plan and safety regulations & standard of oil pipeline by searching and reviewing related regulation & standard inside and outside of the country. Korean regulation & standard is reviewed based on harbor and fishery design standard of the ministry of maritime affairs and fisheries, general technology standard of oil pipeline safety regulation, gas excavation construction and safety maintenance indicator of Korea gas corporation. Global regulation & standard is reviewed based on U.S standard inspection for offshore pipeline and Europe/Mexico standard inspection for offshore pipeline. The contents of offshore pipeline installation is inserted into pipeline sector for objected facilities of safety inspection regulation & standard and, the standard of safety inspection for offshore pipeline is newly presented into pipeline maintenance part of the planning facilities management with its inspection period and method.