• Title/Summary/Keyword: Standard Method

Search Result 13,852, Processing Time 0.039 seconds

Development of a Software PLC for PC Based on IEC 61131-3 Standard (IEC 61131-3 표준을 따른 PC용 소프트웨어 PLC의 개발)

  • Lee, Cheol-Soo;Jeong, Gu;Lee, Je-Phil;Sim, Ju-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.61-69
    • /
    • 2002
  • This paper describes a converting algorithm between programmable languages of a software PLU. It is based on IEC 61131-3 standard and PC. The proposed control logic is designed by the software model and common element with data type, variables, POUs(program organization unit) and execution control unit commonly used within programmable languages of IEC 61131-3 Standard. The generation method of object file is proposed on five programmable language based on IEC 61131-3. It is represented as fo11ows; 1) the generation method using conversion algorithm from LD to IL with FBD(function block diagram), 2) the generation method using f code generation algorithm from SFC using the SFC execution sequence with FBD and ST(structured text). The proposed control logic generator was implemented by Visual C++ 6.0 and MFC on MS-windows NT 4.0.

A Transformation-Based Learning Method on Generating Korean Standard Pronunciation

  • Kim, Dong-Sung;Roh, Chang-Hwa
    • Proceedings of the Korean Society for Language and Information Conference
    • /
    • 2007.11a
    • /
    • pp.241-248
    • /
    • 2007
  • In this paper, we propose a Transformation-Based Learning (TBL) method on generating the Korean standard pronunciation. Previous studies on the phonological processing have been focused on the phonological rule applications and the finite state automata (Johnson 1984; Kaplan and Kay 1994; Koskenniemi 1983; Bird 1995). In case of Korean computational phonology, some former researches have approached the phonological rule based pronunciation generation system (Lee et al. 2005; Lee 1998). This study suggests a corpus-based and data-oriented rule learning method on generating Korean standard pronunciation. In order to substituting rule-based generation with corpus-based one, an aligned corpus between an input and its pronunciation counterpart has been devised. We conducted an experiment on generating the standard pronunciation with the TBL algorithm, based on this aligned corpus.

  • PDF

The Study on the Standard of Test Method for Estimation of Safety and Performance of Ultrasonic Stimulator for Medical Use (초음파자극기의 안전성 및 성능평가를 위한 표준시험방법 연구)

  • Park, S.K.;Na, K.I.;Moon, I.H.;Cha, J.H.;Park, K.J.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 2010
  • Ultrasonic wave stimulator need estimation of quality and security of safety by courtesy call about malfunction or side effect. Need a standard of test method for estimation of safety and performance in type test before marketing or removal examination after marketing for this. In this paper, studied standard of test method for estimation of essential electrical safety and performance for ultrasonic wave stimulator.

Design of Quantization Tables and Huffman Tables for JPEG Compression of Medical Images (의료영상의 JPEG 압축을 위한 양자화 테이블과 허프만 테이블 설계)

  • 양시령;정제창;박상규
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.453-456
    • /
    • 2004
  • Due to the bandwidth and storage limitations medical images are needed to be compressed before transmission and storage. DICOM (Digital Imaging and Communications in Medicine) specification, which is the medical images standard, provides a mechanism for supporting the use of JPEG still image compression standard. In this paper, we explain a method for compressing medical images by PEG standard and propose two methods for JPEG compression. First, because medical images differ from natural images in optical feature, we propose a method to design adaptively the quantization table using spectrum analysis. Second, because medical images have higher pixel depth than natural images do, we propose a method to design Huffman table which considers the probability distribution feature of symbols. Simulation results show the improved performance compared to the quantization table and the adjusted Huffman table of JPEG standard.

On Extending JPEG Compression Method Using Line-based Differential Coding (행/열 단위 증분 부호화를 이용한 JPEG 압축 기법 확장에 관한 연구)

  • Park, Dae-Hyun;Ahn, Young-Hoon;Shin, Hyun-Joon;Wee, Young-Cheul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.15 no.3
    • /
    • pp.11-18
    • /
    • 2009
  • In this paper, we introduce a novel method to extend the JPEG standard, which is the most widely used for lossy image compression, in order to improve compression ratio. To employ two of the most successful methodologies for the data compression: differential coding and quantization simultaneously, we propose a line-based approach. For each line in a block, we apply one-dimensional discrete cosine transformation to the increments instead of the pixel values. Those values are quantized and entropy-coded similarly to the JPEG standard. To further increase compression ratio, the proposed method is plugged into the JPEG standard to form a new compression method, in which the proposed method are applied to only selected JPEG blocks. In our experiment, we found that the proposed method outperform the JPEG standard when the qualities of the coded images are set to be high. We believe the proposed method can be simply plugged into the standard to improve its compression ratio for higher quality images.

  • PDF

Applicability of Huff Model & ABM Method for Discharge Capacity of Sewer Pipe (하수관거 통수능 해석을 위한 Huff 모형과 ABM 법의 적용성 분석)

  • Hyun, Inhwan;Jeon, SeungHui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.4
    • /
    • pp.229-237
    • /
    • 2022
  • The sewer capacity design have been based on the Huff model or the rational equation in South Korea and often failed to determine optimal capacity, resulting in frequent urban flooding or over-sizing. A time distribution of rainfall (i.e., Huff or ABM method) could be used instead of a rainfall hyetograph obtained from statistical analysis of previous rainfalls. In this study, the Huff method and the ABM method, which predict the time distribution of rain intensity, which are widely used to calculate sewage pipe drainage capacity using the SWMM, were compared with the standard rainfall intensity hyetograph of Seoul. If the rainfall duration was 30 minutes to 180 minutes, the rainfall intensity value calculated by the Huff model tended to be less than the rainfall intensity value of the standard rainfall intensity in the initial 5-10 minutes. As a result, more than 10% to 30% of under-design would be made. In addition, the rainfall intensity value calculated by the Huff model from the section excluding the initial 5-10 minutes of rainfall to the rainfall duration was calculated larger than the value using the standard rainfall intensity equation, which would result in an over-design of 10% to 30%. In the case of a relatively long rainfall duration of 360 minutes (6 hours) to 1,440 minutes (24 hours), it showed an lower rainfall intensity of 60 to 90% in the early stages of rainfall, but the problem of under-design had been solved as the rainfall duration time had elapsed. On the other hand, in the alternating block method (ABM) method, it was found that the rainfall intensity at the entire period at each assumed rainfall duration accurately matched the standard rainfall intensity hyetograph of Seoul.

The use of neural networks for the prediction of the settlement of pad footings on cohesionless soils based on standard penetration test

  • Erzin, Yusuf;Gul, T. Oktay
    • Geomechanics and Engineering
    • /
    • v.5 no.6
    • /
    • pp.541-564
    • /
    • 2013
  • In this study, artificial neural networks (ANNs) were used to predict the settlement of pad footings on cohesionless soils based on standard penetration test. To achieve this, a computer programme was developed to calculate the settlement of pad footings from five traditional methods. The footing geometry (length and width), the footing embedment depth, $D_f$, the bulk unit weight, ${\gamma}$, of the cohesionless soil, the footing applied pressure, Q, and corrected standard penetration test, $N_{cor}$, varied during the settlement analyses and the settlement value of each footing was calculated for each method. Then, an ANN model was developed for each traditional method to predict the settlement by using the results of the analyses. The settlement values predicted from the ANN model were compared with the settlement values calculated from the traditional method for each method. The predicted values were found to be quite close to the calculated values. It has been demonstrated that the ANN models developed can be used as an accurate and quick tool at the preliminary designing stage of pad footings on cohesionless soils without a need to perform any manual work such as using tables or charts. Sensitivity analyses were also performed to examine the relative importance of the factors affecting settlement prediction. According to the analyses, for each traditional method, $N_{cor}$ is found to be the most important parameter while ${\gamma}$ is found to be the least important parameter.

Comparison and Evaluation of Performance for Standard Control Limits and Bootstrap Percentile Control Limits in $\bar{x}$ Control Chart ($\bar{x}$ 관리도의 표준관리한계와 부트스트랩 백분률 관리한계의 수행도 비교평가)

  • 송서일;이만웅
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.52
    • /
    • pp.347-354
    • /
    • 1999
  • Statistical Process Control(SPC) which uses control charts is widely used to inspect and improve manufacturing process as a effective method. A parametric method is the most common in statistical process control. Shewhart chart was made under the assumption that measurements are independent and normal distribution. In practice, this assumption is often excluded, for example, in case of (equation omitted) chart, when the subgroup sample is small or correlation, it happens that measured data have bias or rejection of the normality test. A bootstrap method can be used in such a situation, which is calculated by resampling procedure without pre-distribution assumption. In this study, applying bootstrap percentile method to (equation omitted) chart, it is compared and evaluated standard process control limit with bootstrap percentile control limit. Also, under the normal and non-normal distributions, where parameter is 0.5, using computer simulation, it is compared standard parametric with bootstrap method which is used to decide process control limits in process quality.

  • PDF

Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement (급수기구 발생음의 실험실 측정방법 제1부 : 측정방법)

  • 양관섭;정갑철;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.845-850
    • /
    • 2003
  • Noise caused by water installations may lead to annoyance in adjacent rooms, for example in dwellings. hospitals and hotels. This part of standard describes a method of measurement allowing comparable results to be obtained in laboratory measurements. The test conditions described herein constitute the standard reference conditions essential for comparisons between laboratories.

  • PDF

System Level Design of Multi-standard Receiver Using Reconfigurable RF Block

  • Kim, Chang-Jae;Jang, Young-Kyun;Yoo, Hyung-Joun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.3
    • /
    • pp.174-181
    • /
    • 2004
  • In this paper, we review the four receiver architectures and four methods for multi-standard receiver design. Propose reconfigurable RF block can be used for both low-IF and direct conversion architecture. Also, using reconfigurable mixer method, it can be operated at $2{\sim}6$ GHz range for multi-standard receiver. It consists of wideband mixer, filter, and automatic gain control amplifier and to get wide-band operation, $2{\sim}6$ GHz, wide-band mixer use flexible input matching method. Besides, to design multi-standard receiver, LNA bank that support each standard is necessary and it has good performance to compensate the performance of wide-band mixer. Finally, we design and simulate proposed reconfigurable RF block and to prove that it has acceptable performances for various wireless standards, the LNA bank that supports both IEEE 802.11a/b/g and WCDMA is also designed and simulated with it.