• Title/Summary/Keyword: Standard Method

Search Result 13,852, Processing Time 0.039 seconds

Evaluation of Seismic Performance for Bridge Structure Using Capacity Spectrum Method (역량스펙트럼법을 이용한 교량의 내진성능평가)

  • 이창수;김승익;김현겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.75-80
    • /
    • 2000
  • Evaluation method of seismic performance has mainly used elastic spectrum analysis. This method has simplicity of analysis but deficiency of accuracy. And evaluation method of seismic performance using inelastic dynamic analysis reflects accurately inelasticity of material but hardly reflects site effects. This study suggested evaluation scheme of seismic performance for bridge structure using capacity spectrum method applied inelastic static analysis and standard design response spectrum of Korea Standard Specification for Highway Bridge. Two results, capacity spectrum method and inelastic dynamic analysis method, are very similar. As a result, this study appropriately supply both simplicity of analysis and accuracy of result.

  • PDF

The Multi-channel Bio-potential Similarity Research of Acupuncture Point (ST36) and Peripheral Region (다채널 생체전위 측정을 통한 족삼리 주변 피부의 전위 변화 유사도 연구)

  • Lee, Sang-Hun;Cho, Sung-Jin;Choi, Gwang-Ho;Ryu, Yeon-Hee;Kwon, O-Sang;Choi, Sun-Mi
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.41-48
    • /
    • 2011
  • Objectives : This study aimed to explore the passive multi-channel time series analysis method by measuring bio-potentials of acupuncture point and the peripheral region Methods : Bio-potential was measured at ST36 and the peripherical region of ST36 of 5 healthy volunteers at three times. The diagram of the potential changes over time were smoothed by moving average method and similarities of ST36 and the other points were calculated. Results : In the normal weight group, bio-potential similarity tended to decrease in proportion to the distance from the acupuncture point. In the obesity group, bio-potential similarity appeared in a very wide area. Bio-potential similarity had positive correlation with BMI value. Conclusions : The passive multi-channel time series analysis method showed the possibility be appropriate for the electrical characteristics study of meridians.

Assessment for the Comparability between Korean Ministry of Environment Standard and ISO Standard for the Determination of Heavy Metals in Soil (토양 중금속 함량 측정에 대한 토양오염공정시험기준과 국제표준간의 적합성 평가)

  • Shin, Gun-Hwan;Lee, Goon-Teak;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyong;Park, Hyun-Jeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.1-9
    • /
    • 2012
  • According to the agreement on WTO/TBT, we are under the situation to adopt international standard (ISO standard) as a national standard if it exists. However, in case of environmental area, it is a domestic legal obligation to use Korean environmental standard method(KESM) for analyzing various contaminants. Therefore it is necessary to assess the comparability between KEM and ISO standard prior to apply ISO standard to soil conservation law in Korea. The main purpose of this study is to assess the comparability of both methods for analyzing heavy metals in soil. We looked over various aspects like pre-treatment, calibration curve range, detection wavelength, soil organic matter content and so on. Apparently, the procedure of both methods is almost same. However in details, both methods are different in stationary time before aqua-regia extraction using reflux system, calibration curve range for Cu, Pb, Ni and measuring wavelength for Pb. According to the results of comparison test, the results were significantly different when the different calibration range was used. In case that all the extracts independent of methods were reanalyzed with the same calibration range of each method, both methods showed statistically same results. Other conditions like different stationary time, measuring wavelength of AAS and soil organic matter content did not have any influence on the analytical result. Therefore, we suggest to extend the calibration curve range to 0~8 mg/L which is used in KS I ISO standard(Korean standard related with environment which is translation version of ISO standard without any technical change). In case of $Cr^{6+}$, the results showed no significant differences between two methods even though the pretreatment, instrumentation and other analysis conditions were different. In addition to UV/Visble spectrometry of KESM for soil contamination, we suggest to adopt ion chromatography of ISO 15192(US EPA method 7199) for analyzing $Cr^{6+}$ with the consideration of laboratory work efficiency.

Research on Efficient Applicability Through Review on Standard for Selection of Construction Method for Railway Underground Crossing Transit (철도지하횡단 통과 공법 선정기준에 관한 검토를 통해 효율적인 적용성에 대한 연구)

  • Hwang, Young-Ho;Shon, Jung-Chul;Baek, Jong-Myeong
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.595-600
    • /
    • 2007
  • Greater expansion and more frequent operation of the railroad transportation system anticipated due to its characteristics including low cost, safety and mass transportation. Recently, effects on the railway structures due to expansion of newly constructed road, construction of subway, city gas pipeline, communication network, electric power network and construction of other railway underground crossing in accordance with urban planning and organization has influenced safe operation of trains. Accordingly, standard for selection of construction method that will enable construction of more economical and rational subway underground crossing structures by preventing problems occurring at the time of above construction works and accidents in safe operation of trains due to construction in advance is definitively necessary. Although there are numerous construction methods that can be applied at the time of construction of railway underground crossing, there are much difficulties in selection of appropriate construction method that considers characteristics of each construction method on non-excavation type construction method, train operation plan of number of operational routes and on-site circumstances. Therefore, this research aims to present rational standard for selection of construction method for such, and standard for slowdown speed and interception of train when passing the areas of slowdown in sectors under construction.

  • PDF

Process Planning Method under Make-to-Order Production System using Data Mining (데이터마이닝을 이용한 수주생산시스템의 공정계획방안)

  • Oh, Kyung-Mo;Park, Chang-Kwon
    • IE interfaces
    • /
    • v.18 no.2
    • /
    • pp.148-157
    • /
    • 2005
  • The manufacturing industry with Make-to-Order production system is difficult to decide the standard information for the product and the demand is variable to estimate. In this paper, we concerned with the process planning method using data mining in the manufacturing industry with Make-to-Order environment. The subject of our study is the industry transformer plant which is received an diverse order of customer and then produced the product. Currently, process planning method is classified the standard information by hand based on the acquired knowledge through the experience. The standard information stored the various information, such as work sequence, time and so on. This process planning method needs an experts which possesses the field experience for several years. For the product specification which is varied in each order, current process planning method is not efficient due to need many times To solve this problem, we extract the information using data mining process for each processing time, and then construct the knowledge base. We propose a method which is the process planning of the industry transformer product in Make-to-Order environment using the knowledge base.

Investigation of the ASTM International frost heave testing method using a temperature-controllable cell

  • Hyunwoo, Jin;Jangguen, Lee;Byung-Hyun, Ryu
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp. 583-597
    • /
    • 2022
  • Frost heave can cause uneven ground uplift that may damage geo-infrastructure. To assist damage-prevention strategies, standard frost heave testing methods and frost susceptibility criteria have been established and used in various countries. ASTM International standard testing method is potentially the most useful standard, as abundant experimental data have been acquired through its use. ASTM International provides detailed recommendations, but the method is expensive and laborious because of the complex testing procedure requiring a freezing chamber. A simple frost heave testing method using a temperature-controllable cell has been proposed to overcome these difficulties, but it has not yet been established whether a temperature-controllable cell can adequately replace the ASTM International recommended apparatus. This paper reviews the applicability of the ASTM International testing method using the temperature-controllable cell. Freezing tests are compared using various soil mixtures with and without delivering blow to depress the freezing point (as recommended by ASTM International), and it is established that delivering blow does not affect heave rate, which is the key parameter in successful characterization of frost susceptibility. As the freezing temperature decreases, the duration of supercooling of pore water shortens or is eliminated; i.e., thermal shock with a sufficiently low freezing temperature can minimize or possibly eliminate supercooling.

A Study on the Characteristics of Piling Vibration by SIP Method about Variation of Various Earth Conditions (지반조건의 변화에 따른 SIP 항타진동의 특성에 관한 실험적 연구)

  • Kwak, Kwang-Soo;Park, Jae-Young;Lee, Byeong-Yun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.927-932
    • /
    • 2000
  • Recently, construction vibration has caused annoyance for a number of dwellers in nearby construction field and that induced from operating of large construction equipment, has become a very serious issue in our living environment. But, construction vibration standard of our living environment. But construction vibration standard of our country is efficient. Especially, directly blow method(diesel piling method, oil pressure method, etc) has caused much problems of highly impactive vibration. Construction works, in order to solve these problem, will be used SIP(Soilcement Injected Precast Pile) method of low vibration equipment. In this point, this study attempts to survey on the characteristics of piling vibration by SIP method for various earth conditions in construction field. And this study intends to get the basic data to establish a standard about construction vibration.

  • PDF

Improving the Gumbel analysis by using M-th highest extremes

  • Cook, Nicholas J.
    • Wind and Structures
    • /
    • v.1 no.1
    • /
    • pp.25-42
    • /
    • 1998
  • Improvements to the Gumbel method of extreme value analysis of wind data made over the last two decades are reviewed and illustrated using sample data for Jersey. A new procedure for extending the Gumbel method to include M-th highest annual extremes is shown to be less effective than the standard method, but leads to a method for calibrating peak-over-threshold methods against the standard Gumbel approach. Peak-over-threshold methods that include at least the 3rd highest annual extremes, specifically the modified Jensen and Franck method and the "Method of independent storms" are shown to give the best estimates of extremes from observations.

A study on standard implementation method of defense CALS system (국방 CALS체계의 표준 적용방안에 관한 연구)

  • 김철환;송인출
    • Proceedings of the CALSEC Conference
    • /
    • 1999.11a
    • /
    • pp.75-84
    • /
    • 1999
  • CALS is a strategy to share integrated product data through a set of standards to achieve efficiencies in business and operational mission areas. In this research, we first studied current status for CALS standard and then analyzed the case of US DoD. The results can be summarized as implementing for two major standard in defense CALS system. They are STEP and XML. Our recommendations can be used to set direction for CALS standard implementation and standard selection process.

  • PDF