• 제목/요약/키워드: Standard Measuring Technology

검색결과 390건 처리시간 0.027초

수학적 알고리즘에 기초한 스퍼기어 및 헬리컬 기어 모델링에 관한 연구 (A Study on the Modeling of Spur and Helical Gear based on Mathematical Algorithm)

  • 김태호;이승수;김민주;전언찬
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.28-31
    • /
    • 2002
  • In this study, we develop automatic design program, which create 3D model of spur gear and helical gear used VisuaILISP and create helical gear in the CATIA using 2D profile of gear. This model become the standard model, which give not only in itself mold information but also computer processed product with measuring date. Spur gear require mathematical examination of involute curve and trocoidal fillet curve. Automatic design program, which have a mathematical development create the profile of spur gear.

  • PDF

로보틱 토노메트리 센서를 이용한 요골 동맥 파형 정밀 측정 방법 (Precise Measurement Method of Radial Artery Pulse Waveform using Robotic Applanation Tonometry Sensor)

  • 김영민
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.135-140
    • /
    • 2017
  • In this paper, a novel measurement method of radial artery pulse waveform using robotic applanation tonometry (RAT) was present to reduce the errors by the pressing direction of the vessel. The RAT consisted of an array of pressure sensors and 2-axis tilt sensor, which was attached to the universal joint with a linear spring and five-DOF robotic manipulator with a one-axis force sensor. Using the RAT mechanism, the pulse sensor could be manipulated to perpendicularly pressurize the radial artery. A pilot experimental result showed that the proposed mechanism could find the optimal pressurization angles of the pulse sensor within ${\pm}3^{\circ}$standard deviations. Coefficient values of variation of maximum pulse peaks extracted from the pulse waveforms were 4.692, 6.994, and 11.039 % for three channels with the highest magnitudes. It is expected that the proposed method can be helpful to develop more precise tonometry system measuring the pulse waveform on the radial artery.

Water-Side Oxide Layer Thickness Measurement of the Irradiated PWR Fuel Rod by ECT Method

  • Park, Kwang-June;Chun, Yong-Bum
    • Nuclear Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.175-180
    • /
    • 1997
  • It has been known that eater-side corrosion of fuel rods in nuclear reactor is accompanied with the metallic loss of wall thickness and hydrogen pickup in the fuel dadding tube. The fuel dad corrosion is one of the major factors to be controlled to maintain the fuel integrity during reactor operation. An oxide later thickness measuring device equipped with ECT probe system was developed by KAERI, and whose performance test was carried out in NDT(Non-destructive Test) hot-cell or PIE(Post Irradiation Examination) Facility. At first, the calibration/performance test was executed for the unirradiated standard specimen rod fabricated with several kinds of plastic thin films whose thickness ore predetermined, and the result of which showed a good precision within 10% of discrepancy. And then, hot test us peformed for the irradiated fuel rod selectively extracted from J44 fuel assembly discharged from Kori Unit-2. The data obtained with this device were compared with the metallographic result obtained from destructive examination in PIEF hot-cell on the same fuel rod to verify the validity of the measurement data.

  • PDF

소형엔진의 배출가스측정방법에 따른 질소산화물 및 매연에 관한 연구 (A Study on NOx and Smoke by Exhaust Gas Measuring Method of Light-Duty Engine)

  • 한영출;나완용;오용석;문병철;박봉규;박귀열
    • 한국공작기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.7-11
    • /
    • 2001
  • Recently, increasing usage of diesel vehicle, many countries try to reduce the pollutant materials by emission regulation standard. Particularly in our country, the supplement ration of diesel vehicle is high, and air pollution by vehicle exhaust gas is very serious. So, in study, we tested exhaust gas by various mode in-light duty diesel engine. Therefore, we can know about NOx and smoke seriousness.

  • PDF

데오드라이트 시스템의 측정 정확도에 대한 연구(II) -기준자 측정 높이에 따른 측정 정확도 (A Study on Measurement Accuracy of Theodolite System(II) -A Measurement Accuracy for a Height of Scale Bar)

  • 윤용식;이동주;정종길
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.37-43
    • /
    • 2004
  • A measurement accuracy of theodolite system may be affected by a measurement environment, a measurement distance change and so on. This study was performed for measuring an accuracy when the height of scale bar is changed 0.05m, 0.5m, 1m and 1.5m under the distance 3m between two theodolites, the distance 4m from the theodolite system to scale bar and the distance 5m from the thodolite system to the horizontal target bar. And we could know that the best height is 0.05m and 1m.

HEMP 시스템의 설계 요소 분석 (Analysis of Design Elements in HEMP Systems)

  • 이선의;김진영;박우철
    • 한국위성정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.6-11
    • /
    • 2013
  • 본 논문에서는 HEMP의 신호 특성을 설명하고 HEMP 방호시설에 영향을 미치는 요소들을 분석한다. 실제 시설 구축에 이용하기 위한 차폐룸의 규격을 정하기 위해 필요한 요소들을 찾는다. 수신 안테나의 거리와 주파수를 변화시켜 차폐 정도를 측정한다. 기준이 되는 미국 규격문서와 측정값을 비교하고 측정방법을 간소화해본다. 차폐룸 내부를 3가지 조건으로 만들어 변화에 따른 차폐 정도를 측정한다. 정방향 측정과 역방향 측정의 차이를 살펴보고 차폐룸 측정에 영향을 미치는 요소를 찾는다.

TSSG-pulling of Sillenite $Bi_{12}TiO_{20}$ for EOS Application

  • Miyazawa, Shintaro
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1999년도 PROCEEDINGS OF 99 INTERNATIONAL CONFERENCE OF THE KACG AND 6TH KOREA·JAPAN EMG SYMPOSIUM (ELECTRONIC MATERIALS GROWTH SYMPOSIUM), HANYANG UNIVERSITY, SEOUL, 06월 09일 JUNE 1999
    • /
    • pp.227-250
    • /
    • 1999
  • The reproducibility of successive growth of Bi12TiO20(BTO) single crystals using a top-seeded solution growth (TSSG) pulling method was evaluated by measuring the lattice constants and their standard deviations. A substantial phase diagram in the region close to the stoichiometric BTO was established experimentally for this purpose, and the existence of a retrograde solid solution close to a BTO was clarified. It was emphasize that a starting solution, with a 10.0~10.1 mol% TiO2 concentration, results in large single crystals with a highly homogeneous lattice constant of within $\pm$1x10-4$\AA$, when the solidified fraction of the grown crystal is less than about 45%. A wavelength dispersion of refractive index was measured for the first time, an it was verified that the refractive index of BTO is larger than that of BSO(Bi12TiO20), allowing the voltage sensitivity of EOS higher than the case with BSO as a probe head.

  • PDF

공압서보밸브 KS규격 정립에 관한 연구 (A Study of Korean (Industrial) Standards for Pneumatic Servo Valve)

  • 김동수;이원희;최병오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1231-1234
    • /
    • 2003
  • Pneumatic servo valve which is widely applied in industrial world is advanced technology compounded with electric, electronic and machine. And It is consist of Linear Force Motor. Spool Commutation Mechanism and Microprocessor. In this study, we accomplished test method of Linear Force motor test, Static characteristic test, Dynamic characteristic test for KS(Koran industrial standard) of Pneumatic servo valve. we accomplished study about the main item of Static characteristic test which is related to unload flow characteristic test. And Dynamic characteristic test was step input test and frequency response test. Specially about frequency response test, There was a difficulty resulting from the time delay problem caused by the basic compressibility of air. In order to solve the problem in this study. we proposed two methods. First, displacement of the servo valve spool was directly measured by using a laser sensor. Second, method of calculating control flow by measuring pressure and temperature of chamber.

  • PDF

Ethanol 및 그 Ester의 Fluorine Derivatives중(中) ${\beta}$-체(體)의 확인(確認) 및 정량(定量)에 관(關)한 연구(硏究) (Identification and Spectrophotometric Method for Determination of the ${\beta}-Fluorine$ Compounds in Fluorides of Ethanol and its Ester)

  • 심영기;이한표;구기서;김재백
    • Journal of Pharmaceutical Investigation
    • /
    • 제4권1_2호
    • /
    • pp.1-6
    • /
    • 1974
  • S-Benzylthiuronium chloride reacts with ethylene glycol, derived from hydrolysis of the fluorides, to produce a crystalline substances. Using this, the fluorides can be indentified by measuring melting point. And when the zirconium-alizarin solution reacts with ethylenefluoro hydrin or ${\beta}-fluoroethyl$ acetate, the red-violet color disappears to produce a yellow dye, which exhibits absorption maximum at about $530\;m{\mu}$ using the 250-microgram standard. Using these properties, the fluorine compounds can be determined conveniently by this method.

  • PDF

Correlation between microleakage and screw loosening at implant-abutment connection

  • Sahin, Cem;Ayyildiz, Simel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.35-38
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS. Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titanium) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (${\alpha}=0.05$). RESULTS. Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION. Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.