• 제목/요약/키워드: Standard Dose

검색결과 959건 처리시간 0.031초

Cucumber (Cucumis sativus L.) Fruit and Combination with Losartan Attenuate the Elevation of Blood Pressure in Hypertensive Rats Induced by Angiotensin II

  • Tomi Hendrayana;Klaudia Yoana;I Ketut Adnyana;Elin Yulinah Sukandar
    • 대한약침학회지
    • /
    • 제26권4호
    • /
    • pp.298-306
    • /
    • 2023
  • Objectives: Cucumis sativus L. (C. sativus) is vegetable commonly used for managing blood pressure and often consumed in combination with standard antihypertensive therapy, despite lack of scientific evidence supporting their use. Combination of herbs and standard medication could have positive or negative effects. Therefore, this study aimed to evaluate the antihypertensive activity of C. sativus and the combined effect with losartan in the hypertensive rat model induced by angiotensin II. Angiotensin II is a component of the renin-angiotensin-aldosterone system that, upon binding to its receptor, constricts blood vessels leading to elevation of blood pressure. Methods: In an antihypertensive study, rats received C. sativus orally at doses of 9, 18, 27, and 36 mg/kg (full dose); while in a combination study, animals received losartan 2.25 mg/kg combined by either with C. sativus 9 or 18 mg/kg. The standards group received losartan 2.25 mg/kg or 4.5 mg/kg (full dose). Results: Blood pressure was measured using the tail-cuff method. C. sativus significantly attenuated angiotensin II-induced hypertension as observed in groups receiving C. sativus at 9, 18, 27, and 36 mg/kg at 30 minutes after induction showed the average change (Δ) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) with respect to time zero were 28.8/18.3, 24.8/15.8, 22.8/15.5, and 11.5/9.0 mmHg, respectively. Whereas the average change (Δ) of SBP and DBP in the rats receiving the combination of half doses of C. sativus and losartan were 8.8/9.0 mmHg, respectively. These diminished effects were better than a full dose of C. sativus and comparable with a full dose of losartan (6.5/7.8 mmHg). Conclusion: The present findings indicate that C. sativus dose-dependently blocks blood pressure elevation induced by angiotensin II. The combination of half dose of C. sativus and losartan has an additive effect in lowering blood pressure.

흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교 (Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol)

  • 이원정;안봉선;박영선
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.84-89
    • /
    • 2012
  • 임상에서 사용하고 있는 흉부 CT촬영의 저선량 프로토콜과 표준선량 프로토콜 간의 선량과 화질을 비교 분석하였다. 흉부 저선량 프로토콜(120 kVp, 30 mAs)과 표준선량 프로토콜(120 kVp, 180 mAs)로 촬영($Brilliance^{TM}$ CT 16slice, PHILIPS)한 61명의 조영제를 사용하지 않은 영상에서 기관 분기부 위치의 종격동 영상을 본 연구를 위해 사용하였다. 상행대동맥과 가시아래근에서 CT number와 잡음을 측정하였고, Back-ground 잡음을 측정하여 신호대잡음비(signal-to-noise ratio. SNR)와 대조도잡음비(contrast-to-noise ratio, CNR)를 구하였다. 두부 아크릴 팬텀을 이용하여 선량을 측정하였고, 워터 팬텀으로 얻은 영상에서 CT number와 잡음을 측정하였다. 모든 측정은 3회 실시하여 평균값을 SPSS 프로그램(version 14.0)으로 분석하였고, 그래프는 시그마 플롯 프로그램(version10.0)을 사용하였다. 결과: 상행대동맥과 가시아래근에서 저선량 프로토콜 영상이 표준선량 프로토콜 영상 보다 유의하게 높은 잡음을 보였고, SNR과 CNR은 유의하게 낮았다. 두 영상에서 비만지수에 대한 잡음은 양의 관련성을 보였지만, SNR과 CNR은 음의 관련성을 보였다. 팬텀 결과에서 저선량 프로토콜의 선량이 표준선량 프로토콜 보다 유의하게 낮았지만(0.35 mGy vs. 1.95 mGy, p=0.008), 잡음은 저선량 프로토콜에서 유의하게 높았다(p=0.029). 저선량 프로토콜이 표준선량 프로토콜 보다 유의하게 낮은 선량을 보였지만, 화질 평가도 유의하게 낮은 결과를 보임으로서 임상에서 사용하는 저선량 프로토콜의 노출 선량은 화질을 고려하여 상향 조정할 필요가 있다.

몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가 (Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation)

  • 조일성;곽정원;조병철;김종훈;안승도;박성호
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.81-90
    • /
    • 2012
  • 방사선 치료에서 부정확한 환자 셋업이 표적에 전달되는 선량에 미치는 영향과 치료 마진과의 연관성을 몬테칼로 기법을 사용한 전산모사를 통하여 분석하였다. 실제 방사선 치료를 받은 직장암 환자에 대한 임상표적체적(CTV: Clinical Target Volume) 및 주요장기의 구조와 치료계획 시스템(Eclipse 8.9, USA)을 이용하여 수립된 세기조절 방사선치료계획에서의 선량분포에 대한 데이터를 전산모사에서 사용하였다. 전산모사 프로그램은 리눅스환경에서 오픈소스인 ROOT 라이브러리와 GCC를 기반으로 본 연구를 위하여 개발되었다. 환자셋업오차의 확률분포를 정규분포로 가정한 것에 따라 무작위로 생성된 크기만큼 셋업이 부정확한 경우를 모사하여 임상표적체적에서의 선량분포의 변화와 오차크기에 따른 마진크기를 3차원입체조형 방사선치료에 사용되는 마진공식과 비교분석 하였다. 셋업오차 생성에 사용된 정규분포의 표준편차 크기는 1 mm부터 10 mm까지 1 mm간격으로 두었으며 계통오차와 통계오차별로 2,000번 전산모사했다. 계통오차의 경우 전산모사에 사용된 표준편차가 커질수록 임상표적체적에 조사되는 최소선량 $D_{min}^{stat{\cdot}}$은 100.4%에서 72.50%로 감소하였고 평균선량 $\bar{D}_{syst{\cdot}}$도 100.45%에서 97.88%로 감소한 반면에 표준편차${\Delta}D_{sys}$는 0.02%에서 3.33%로 증가하였다. 통계오차의 경우 최소선량 $D_{min}^{rand{\cdot}}$은 100.45%에서 94.80%감소하였고 평균선량 $\bar{D}_{syst{\cdot}}$도 100.46%에서 97.87%로 감소하였으며 표준편차 ${\Delta}D_{rand}$는 0.01%에서 0.63%로 증가하였다. 그리고 마진공식으로부터 전산모사에 사용된 셋업오차에 해당되는 마진크기를 구하고 모집단비율(population ratio)을 정의하여 기존 마진공식의 목적이 세기조절방사선치료에 만족함을 확인했다. 개발된 전산모사 프로그램은 해당 환자의 치료계획 정보를 직접 사용하므로 직장암만 아니라 두경부암, 전립선암 등 여러 환부에 적용 가능하며 셋업오차 및 선량변화에 연관된 연구에도 사용할 수 있을 것으로 사료된다.

대향2문조사시 Target Volume의 위치에 따른 Beam Weight의 최적화

  • 이진국;김지한;임익수;최영헌
    • 대한방사선치료학회지
    • /
    • 제5권1호
    • /
    • pp.68-73
    • /
    • 1992
  • If the same weight is used in parallel opposed 6 and 10 MV x-ray beams, the lowest dose is achieved at SAD. Therefore, dose homogeneity in the target volume is decreased when SAD is taken at center of target volume than center of phantom or patient. With Standard deviation of ${\pm}6\%$ that repuesented the dose homogeneity in tarhet volume, we studied the optimized beam weights at which hot spot dose was least in parallel opposed beams. The optimized beam weights that maximally decrease the hot spot dose, wer 1.29, 1.19, 2.71, 3.50, and 4.70 in 6 MV x-ray and 1.25, 1.53, 1.90, 2.36, 3.01, and 3.7 in 10 MV x-ray, reapectively, when center of target volume was changed to 2,4,6,8,10, and 12cm from center plan of phantom along the centeral axis of beams.

  • PDF

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

Aspartate함유 복합성분과 Ethanol의 약물동태학적 거동 (Pharmacokinetics of Ethanol After Oral Administration of Aspartate-Containing Compositions)

  • 김태완;이범진;최한곤;김종국;신희종;김정우
    • Journal of Pharmaceutical Investigation
    • /
    • 제27권3호
    • /
    • pp.181-187
    • /
    • 1997
  • The purpose of this work was to investigate pharmacokinetics of alcohol as a function of dose and time of administration of ethanol. The pharmacokinetics of alcohol 15 min after and before oral administration of aspartate-containing compositions to rats were also evaluated. The retention time of acetaldehyde, alcohol and isopropyl alcohol an internal standard in gas chromatogram was 3.6, 6.0 and 10.5 min, respectively. The maximum concentration of alcohol $(C_{max})$ and area under the blood concentration (AUC) were significanly increased as a function of ethanol dose in a nonlinear fashion. The significant diurnal variation of alcohol pharmacokinetics was also noted, showing fast metabolism and elimination when given orally in the night time. When APAP was given after administration alcohol (1g/kg) to rats, AUC and $C_{max}$ were increased when compared to alcohol only. However, AUC and $C_{max}$ were decreased when aspartate or standard complex compositions containing aceaminophen (APAP, 250mg). sodium L-aspartate(25 mg), dl-methionine (125 mg) and anhydrous caffeine (25 mg) was orally given by coupling malate/asparate shuttle in hepatocyte. The blood alcohol concentration profiles between aspartate and standard complex compositions were similar when given before or after administration alcohol (1g/kg) to rats. No significant difference of administration sequence was observed. However, it was noted that AUC and $C_{max}$ of standard complex compositions given before alcohol administration were significantly lower when compared with alcohol only. Based on these findings, dose, time of administration and composition of drugs to improve alcohol metabolism and elimination were considered to be important in the pharmacokinetics of alcohol. The administration sequence of drug compositions and alcohol might be also considerd.

  • PDF

Status of Radiation Dose and Radioactive Contamination due to the Fukushima Accident

  • Baba, Mamoru
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.133-140
    • /
    • 2016
  • Backgrounds: The accident at Fukushima Daiichi Nuclear Power Plant (NPP), March 2011, caused serious radioactive contamination over wide area in east Japan. Therefore, it is important to know the effect of the accident and the status of NPP. Materials and Methods: This paper provides a review on the status of radiation dose and radioactive contamination caused by the accident on the basis of publicized information. Results and Discussion: Monitoring of radiation dose and exposure dose of residents has been conducted extensively by the governments and various organizations. The effective dose of general residents due to the accident proved to be less than a mSv both for external and internal dose. The equivalent committed dose of thyroid was evaluated to be a few mSv in mean value and less than 50 mSv even for children. Monitoring of radioactivity concentration has been carried out on food ingredients, milk and tap water, and actual meal. These studies indicated the percentage of foods above the regulation standard was over 10% in 2011 but decreasing steadily with time. The internal dose due to foods proved to be tens of ${\mu}Sv$ and much less than that due to natural $^{40}K$ even in the Fukushima area and decreasing steadily, although high level concentration is still observed in wild plants, wild mushrooms, animals and some kind of fishes. Conclusion: According to extensive studies, not only the effect of the accident but also the pathway and countermeasures against radioactive contamination have been revealed, and they are applied very effectively for restoration of environment and reconstruction of the area.

소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교 (Comparison of ESD and Major Organ Absorbed Doses of 5-Year-Old Standard Guidelines and Clinical Exposure Conditions)

  • 강아름;이인자;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.355-361
    • /
    • 2017
  • 소아는 성인보다 장기의 방사선에 대한 감수성이 크고 성장 중이기 때문에 더 민감하다. 피폭으로 인한 부작용을 겪는 기대수명이 길기 때문에 피폭선량의 관리가 어른의 경우보다 중요하게 다뤄진다. 본 연구는 10세 팬텀을 사용하여 현재 우리나라에 권고되어 있는 5세 소아의 촬영기준과 입사표면선량의 적합성을 확인하고 추가적으로 제시된 촬영기준으로 장기흡수선량을 측정해보았다. 임상에서 사용 중인 5세와 10세의 촬영조건과 장기흡수선량, 입사표면선량을 비교하였다. 임상 5세 촬영조건이 권고촬영조건보다 약간 높으며 임상 10세 촬영조건은 많이 높게 나타났다. 또한 권고 촬영조건으로 ESD를 측정한 결과 임상 촬영조건의 ESD가 43% 높게 나타났으며 10세의 ESD는 5세의 권고 촬영조건의 ESD 보다 126% 증가를 나타냈다. 5세의 권고된 ESD와 임상 촬영조건에 의한 ESD를 비교한 결과 31.6%의 차이를 나타냈다. 5세의 권고 촬영조건과 임상 촬영조건에 의한 장기흡수선량은 큰 차이는 없으나 흉부와 골반검사에서는 차이가 컸다. 그러나 10세의 임상 촬영조건에 의한 장기흡수선량을 비교하면 월등한 차이가 있었음을 알 수 있었다. 따라서 소아의 권고 선량에 대한 더욱 세분화된 기준안이 연구되어야 할 것으로 사료된다.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

Radiation exposure dose in human blood lymphocytes as assessed by the CBMN assay

  • Ryu, Tae Ho;Kim, Jin-Hong;Kim, Jin Kyu
    • Journal of Ecology and Environment
    • /
    • 제37권4호
    • /
    • pp.195-200
    • /
    • 2014
  • The chances of accidental exposure are augmented as the application of ionizing radiation increases in various fields. Such accidental exposures may occur at nuclear power plants, laboratories, and hospitals. Cytogenetic assays have been used for estimating radiation dose in the situation of the accidents. The micronucleus assay has several advantages over the other cytogenetic methods as it is simple and fast. The present study aimed at investigation of the micronuclei frequencies in cytokinesis-block cells in human blood lymphocytes after ${\gamma}$-irradiation and at establishment of a standard dose response relationship. The samples of peripheral blood were obtained from 6 different donors aged between 24 and 30 years old. The bloods were irradiated in vitro with 0-5 Gy. A linear quadratic dose-response equation was obtained by scoring the micronuclei in binucleated cells; $y=27.87x^2+46.13x+2.08$ ($r^2=0.99$). Irradiation caused a significant decrease in the nuclear division index. Necrotic and apoptotic cells increased in number after irradiation in a dose-dependent manner. In conclusion, the conventional cytokinesis-block micronucleus assay has proven to be the great technique in biological dosimetry. Dose-response calibration curve derived from CMBN assay could be used to estimate the exposure dose during a radiological emergency.