• Title/Summary/Keyword: Standard 2800

Search Result 10, Processing Time 0.029 seconds

A Study on the Lighting Environment Standard for Museum Exhibition Halls, with a Focus on Color Temperature (박물관 전시 공간 조명 환경 기준 연구(I) - 색온도를 중심으로)

  • Lee, Sungeun;Roh, Hyunsook
    • Conservation Science in Museum
    • /
    • v.18
    • /
    • pp.65-76
    • /
    • 2017
  • Following advances in technology and with the growing need for renewable energy, fluorescent and halogen lamps are being replaced by LED lighting in museum systems. This paper researched the setting of standards for the diverse lighting systems in addition to the LED lighting that are expected to be introduced in museums in the future. Contrary to previous belief, LEDs were shown to only barely emit in the ultraviolet region, but the visible rays were confirmed to produce discoloration depending on illuminance-hours. When the color change by LED lamps at the color temperature of 2800K, or warm white, was compared with 5500K, or white, the emission spectrum analysis confirmed that the blue spike increased at a higher color temperature and caused more discoloration. This suggests that in addition to illumination, color temperature should be considered by including the emission spectrum when museums set lighting environment standards.

Evaluation of Seismic performance of RC setback frames

  • Habibi, Alireza;Vahed, Meisam;Asadi, Keyvan
    • Structural Engineering and Mechanics
    • /
    • v.66 no.5
    • /
    • pp.609-619
    • /
    • 2018
  • When the irregularities occurred in buildings, affect their seismic performance. This paper has focused on one of the types of irregularities at the height that named setback in elevation. For this purpose, several multistorey Reinforced Concrete Moment Resisting Frames (RCMRFs) with different types of setbacks were designed according to new edition of Iranian seismic code. The nonlinear time history analysis was performed to predict the seismic performance of frames subjected to seven input ground motions. The assessment of the seismic performance was done considering both global and local criteria. Results showed that the current edition of Iranian seismic code needs to be modified in order to improve the seismic behaviour of reinforced concrete moment resisting setback buildings. It was also shown that the maximum damages happen at the elements located in the vicinity of the setbacks. Therefore, it is necessary to strengthen these elements by appropriate modification of Iranian seismic code.

Seismic vulnerability evaluation of a 32-story reinforced concrete building

  • Memari, A.M.;Motlagh, A.R. Yazdani;Akhtari, M.;Scanlon, A.;Ashtiany, M. Ghafory
    • Structural Engineering and Mechanics
    • /
    • v.7 no.1
    • /
    • pp.1-18
    • /
    • 1999
  • Seismic evaluation of a 32-story reinforced concrete framed tube building is performed by checking damageability, safety, and toughness limit states. The evaluation is based on Standard 2800 (Iranian seismic code) which recommends equivalent lateral static force, modal superposition, or time history dynamic analysis methods to be applied. A three dimensional linearly elastic model checked by ambient vibration test results is used for the evaluation. Accelerograms of three earthquakes as well as linearly elastic design response spectra are used for dynamic analysis. Damageability is checked by considering story drift ratios. Safety is evaluated by comparing demands and capacities at the story and element force levels. Finally, toughness is studied in terms of curvature ductility of members. The paper explains the methodology selected and various aspects in detail.

Fragility assessment of RC-MRFs under concurrent vertical-horizontal seismic action effects

  • Farsangi, Ehsan Noroozinejad;Tasnimi, Abbas Ali;Mansouri, Babak
    • Computers and Concrete
    • /
    • v.16 no.1
    • /
    • pp.99-123
    • /
    • 2015
  • In this study, structural vulnerability of reinforced concrete moment resisting frames (RC-MRFs) by considering the Iran-specific characteristics is investigated to manage the earthquake risk in terms of multicomponent seismic excitations. Low and medium rise RC-MRFs, which constitute approximately 80-90% of the total buildings stock in Iran, are focused in this fragility-based assessment. The seismic design of 3-12 story RC-MRFs are carried out according to the Iranian Code of Practice for Seismic Resistant Design of Buildings (Standard No. 2800), and the analytical models are formed accordingly in open source nonlinear platforms. Frame structures are categorized in three subclasses according to the specific characteristics of construction practice and the observed seismic performance after major earthquakes in Iran. Both far and near fields' ground motions have been considered in the fragility estimation. An optimal intensity measure (IM) called Sa, avg and beta probability distribution were used to obtain reliable fragility-based database for earthquake damage and loss estimation of RC buildings stock in urban areas of Iran. Nonlinear incremental dynamic analyses by means of lumped-parameter based structural models have been simulated and performed to extract the fragility curves. Approximate confidence bounds are developed to represent the epistemic uncertainties inherent in the fragility estimations. Consequently, it's shown that including vertical ground motion in the analysis is highly recommended for reliable seismic assessment of RC buildings.

Sensitivity study of the Yfiler® PLUS PCR Amplification Kit in forensic casework samples (법과학 현장시료에서 Yfiler® PLUS PCR Amplification Kit의 민감도 연구)

  • Jung, Ju Yeon;Kim, Kyoung Sook;Park, Sun Wha;Lim, Si Keun;Lee, Dong Sub;Lee, Yang Han
    • Analytical Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.43-48
    • /
    • 2016
  • A variety of Y-STR analysis kits have been developed and used in the forensic field. Prior to the forensic application of a new kit, laboratory validation and sensitivity tests are essential processes in selecting suitable alternatives and for assuring that standard operating procedures are followed. In this paper, we have performed a sensitivity study of a new commercial kit, the Yfiler® PLUS PCR Amplification Kit (Yfiler plus kit, released in 2014) by comparing it with the AmpF/STR® YfilerTM PCR Amplification Kit (Yfiler kit, released in 2004). The Yfiler plus kit includes the 17 Y-STR loci of the Yfiler kit and has been supplemented with 10 new Y-STR loci. First, we analyzed the sensitivity difference between the two kits using commercial control DNA 2800M and 007. In addition, we compared the detection rate between the two kits from the 16 selected forensic casework samples of less than 0.5 ng concentrations. The results show that the sensitivity and detection rate of the Yfiler plus kit are higher than the corresponding rates of the Yfiler kit. In addition, we were able to obtain more Y-STR profiles with the use of the new kit. Thus, we suggest that Yfiler plus kit is a more effective forensic tool to detect Y-STR profiles from forensic casework samples of low concentrations.

Comparison of InGaef etching $BCl_3,\;BCl_3/Ar\;and\;BCl_3/Ne$ inductively coupled plasmas ($BCl_3,\;BCl_3/Ar,\;BCl_3/Ne$ 유도결합 플라즈마에 의한 InGaP 건식 식각 비교)

  • Baek, In-Kyoo;Lim, Wan-Tae;Lee, Je-Won;Jo, Guan-Sik;Jeon, Min-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.361-365
    • /
    • 2003
  • Planar Inductively Coupled Plasma (PICP) etching of InGaP was performed in $BCl_3,\;BCl_3/Ar\;and\;BCl_3/Ne$ plasmas as a function of ICP source power ($0\;{\sim}\;500\;W$), RIE chuck power ($0\;{\sim}\;150\;W$), chamber pressure ($5\;{\sim}\;15\;mTorr$) and gas composition of $BCl_3/Ar\;and\;BCl_3/Ne$. Total gas flow was fixed at 20 sccm (standard cubic centimeter per minute). Increase of ICP source power and RIE chuck power raised etch rate of InGaP, while that of chamber pressure reduced etch rate. We also found that some addition of Ar and Ne in $BCl_3$ plasma improved etch rate of InGaP. InGaP etch rate was varied from $1580\;{\AA}/min$ with pure $BC_3\;to\;2800\;{\AA}/min$ and $4700\;{\AA}/min$ with 25 % Ar and Ne addition, respectively. Other process conditions were fixed at 300 W ICP source power, 100 W RIE chuck power and 7.5 mTorr chamber pressure. SEM (scanning electron microscopy) and AFM (atomic force microscopy) data showed vertical side wall and smooth surface of InGaP at the same condition. Proper addition of noble gases Ar and Ne (less than about 50 %) in $BCl_3$ inductively coupled plasma have resulted in not only increase of etch rate but also minimum preferential loss and smooth surface morphology by ion-assisted effect.

  • PDF

Discrete-Time Analysis of Throughput and Response Time for LAP Derivative Protocols under Markovian Block-Error Pattern (마르코프 오류모델 하에서의 LAP 계열 프로토콜들의 전송성능과 반응시간에 대한 이산-시간 해석)

  • Cho, Young-Jong;Choi, Dug-Kyoo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.11
    • /
    • pp.2786-2800
    • /
    • 1997
  • In this paper, we investigate how well the channel memory (statistical dependence in the occurrence of transmission errors) can be used in the evaluation of widely used error control schemes. For this we assume a special case named as the simplest Markovian block-error pattern with two states, in which each block is classified into two classes of whether the block transmission is in error or not. We apply the derived pattern to the performance evaluation of the practical link-level procedures, LAPB/D/M with multi-reject options, and investigate both throughput and user-perceived response time behaviors on the discrete-time domain to determine how much the performance of error recovery action is improved under burst error condition. Through numerical examples, we show that the simplest Markovian block-error pattern tends to be superior in throughput and delay characteristics to the random error case. Also, instead of mean alone, we propose a new measure of the response time specified as mean plus two standard deviations 50 as to consider user-perceived worst cases, and show that it results in much greater sensitivity to parameter variations than does mean alone.

  • PDF

Seismic vulnerability macrozonation map of SMRFs located in Tehran via reliability framework

  • Amini, Ali;Kia, Mehdi;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.78 no.3
    • /
    • pp.351-368
    • /
    • 2021
  • This paper, by applying a reliability-based framework, develops seismic vulnerability macrozonation maps for Tehran, the capital and one of the most earthquake-vulnerable city of Iran. Seismic performance assessment of 3-, 4- and 5-story steel moment resisting frames (SMRFs), designed according to ASCE/SEI 41-17 and Iranian Code of Practice for Seismic Resistant Design of Buildings (2800 Standard), is investigated in terms of overall maximum inter-story drift ratio (MIDR) and unit repair cost ratio which is hereafter known as "damage ratio". To this end, Tehran city is first meshed into a network of 66 points to numerically locate low- to mid-rise SMRFs. Active faults around Tehran are next modeled explicitly. Two different combination of faults, based on available seismological data, are then developed to explore the impact of choosing a proper seismic scenario. In addition, soil effect is exclusively addressed. After building analytical models, reliability methods in combination with structure-specific probabilistic models are applied to predict demand and damage ratio of structures in a cost-effective paradigm. Due to capability of proposed methodology incorporating both aleatory and epistemic uncertainties explicitly, this framework which is centered on the regional demand and damage ratio estimation via structure-specific characteristics can efficiently pave the way for decision makers to find the most vulnerable area in a regional scale. This technical basis can also be adapted to any other structures which the demand and/or damage ratio prediction models are developed.

Discrimination of dicentric chromosome from radiation exposure patient data using a pretrained deep learning model

  • Soon Woo Kwon;Won Il Jang;Mi-Sook Kim;Ki Moon Seong;Yang Hee Lee;Hyo Jin Yoon;Susan Yang;Younghyun Lee;Hyung Jin Shim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3123-3128
    • /
    • 2024
  • The dicentric chromosome assay is a gold standard method to estimate radiation exposure by calculating the ratio of dicentric chromosomes existing in cells. The objective of this study was to propose an automatic dicentric chromosome discrimination method based on deep convolutional neural networks using radiation exposure patient data. From 45 patients with radiation exposure, conventional Giemsa-stained images of 116,258 normal and 2800 dicentric chromosomes were confirmed. ImageNet was used to pre-train VGG19, which was modified and fine-tuned. The proposed modified VGG19 demonstrated dicentric chromosome discrimination performance, with a true positive rate of 0.927, a true negative rate of 0.997, a positive predictive value of 0.882, a negative predictive value of 0.998, and an area under the receiver operating characteristic curve of 0.997.

Effect of Cooling Water Capacity on the Engine Performance for Small Diesel Engine (냉각수(冷却水) 용량(容量)이 소형(小型) 디젤기관(機關)의 성능(性能)에 미치는 영향(影響))

  • Myung, Byung Soo;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.2
    • /
    • pp.265-278
    • /
    • 1986
  • This study was attempted to improve the thermal efficiency of 6 kW water-cooled diesel engine on power tiller. The engine performance tests were conducted to find out the effect of cooling water capacity of 2700cc, 2800cc, 2900cc, 3000cc, 3100cc on power, brake specific fuel consumption (BSFC), torque, temperature of cooling water and lubricating oil and friction losses of the engine with D. C. dynamometer. The results obtained in the study are summarized as follows: 1. The performance of the engine tested was adequated to Korea Industrial Standard but actual economy power was 10% higher than the labeled rated power of the engine. The BSFC of the engine tested 297.8g/kW-h which is belong a little higher level than hreign products. The temperature of cooling water was $101^{\circ}C$ which is higher than SAE standard ($88^{\circ}C$) 2. The friction losses of engine tested was 3.656 kW at 2200 rpm of rated rpm (piston speed 6.97m/sec) and is higher than those of foreign products. 3. When the cooling water capacity was increased from 2700cc to 3100cc the power output of the engine was increased from 6.7 kW to 7.13 kW at the rate of 6.4% and also the torque of the engine was increased from 28.85 N.m to 30.76 N.m at the rate of 6.39%. 4. When the cooling water capacity was increased from 2700cc to 3100cc, the BSFC was decreased 6.9g/kW-h from 310.9g/kW-h to 304.1g/kW-h, and after one half hour operation with full load, the temperature of cooling water was decreased $13^{\circ}C$ from $101^{\circ}C$ to $88^{\circ}C$ and also the temperature of lubricant oil was decreased $6.4^{\circ}C$ from $76.7^{\circ}C$ to $70.4^{\circ}C$. 5. The mechanical efficiency was increased from 70.08% to 71.08% when the cooling water capacity was increased from 2700cc to 3100cc.

  • PDF