DOI QR코드

DOI QR Code

Seismic vulnerability evaluation of a 32-story reinforced concrete building

  • Memari, A.M. (Department of Civil and Environmental Engineering, The Pennsylvania State University) ;
  • Motlagh, A.R. Yazdani (International Institute for Earthquake Engineering and Seismology) ;
  • Akhtari, M. (International Institute for Earthquake Engineering and Seismology) ;
  • Scanlon, A. (The Pennsylvania State University) ;
  • Ashtiany, M. Ghafory (International Institute for Earthquake Engineering and Seismology)
  • Published : 1999.01.25

Abstract

Seismic evaluation of a 32-story reinforced concrete framed tube building is performed by checking damageability, safety, and toughness limit states. The evaluation is based on Standard 2800 (Iranian seismic code) which recommends equivalent lateral static force, modal superposition, or time history dynamic analysis methods to be applied. A three dimensional linearly elastic model checked by ambient vibration test results is used for the evaluation. Accelerograms of three earthquakes as well as linearly elastic design response spectra are used for dynamic analysis. Damageability is checked by considering story drift ratios. Safety is evaluated by comparing demands and capacities at the story and element force levels. Finally, toughness is studied in terms of curvature ductility of members. The paper explains the methodology selected and various aspects in detail.

Keywords

References

  1. Adachi, M. and Nagata M. (1990), "Structural design and analysis of new Tokyo City Hall Tower", Proceedings, 4th World Congress, Tall Bnildings: 2000 and Beyond, Council on Tall Buildings and Urban Habitat, Hong Kong, 833-843.
  2. American Concrete Institute. (1989), "Building code requirements for structural concrete," ACI 318-89, Farmington Hills, MI.
  3. Applied Technology Council. (1978), "Tentative provisions for the development of seismic regulations for buildings" , ATC Publication 3-06.
  4. Anderson, J.C. and Agbabian, M.S. (1994), "Failure analysis of a ten story building in Armenia", Proceedings, 5th U.S. Conference on Earthquake Engineering, Chicago, Ill, 421-430.
  5. Building and Housing Research Center (BHRC). (1988), "Iranian code for seismic resistant design of buildings" , Standard 2800.
  6. Burns, N.H. and Siess, CP. (1962), "Load-deformation characteristics of beam-column connection in reinforced concrete", Civil Engineering Studies, Structural Research Series No. 234, University of Illinois.
  7. Crawford, R. and Ward, H.S. (1964), "Determination of natural periods of buildings", Bulletin of Seismological Society of America, 54 1743-1756.
  8. Federal Emergency Management Agency. (1994), NEHRP Recommended Provisions for Seismic Regulations for New Buildings, 1994 Edition, FEMA 222A/May 1995, Building Seismic Safety Council, Washington, D.C
  9. Fintel, M. and Ghosh, S.K. (1991), "Explicit inelastic dynamic design procedure for earthquake resistant structures", Earthquake-Resistant Concrete Structures Inelastic Response and Design, Edited by S. K. Ghosh, ACI SP-127, 503-538.
  10. Housner, G.W. (1959), "Behavior of structures during earthquakes", Proceedings, ASCE, 85(EM4), 109-129.
  11. Habibullah, A. (1986), "Extended three dimensional analysis of building systems", Computers and Structures, Inc., Berkeley, Calif.
  12. Hosahalli, S., Toksoy, T., and Aktan, A.E. (1992), "Closed-loop modal testing of a 27-story concrete flat plate-core building", NCEER Bulletin-April 1992, 7-11.
  13. International Institute for Earthquake Engineering and Seismology (IIEES), (1991), Manjil-Roudbar Earthquake of June 20, 1990, Pub. 70-1.
  14. Jeary, A.P. and Ellis, B.R. (1981), ''Vibration tests of structures at varied amplitudes", Proceeings of the Second Specialty Conference on Dynamic Response of Structures: Experimentation, Observation, Prediction, and Control, ASCE, Atlanta, Georgia, 281-294.
  15. Kent, D.C. and Park, R. (1971), "Flexural members with confined concrete", Journal of Structural Division, ASCE, 97(ST 7), 1969-1990.
  16. Khan, F.R. and Amin, N.R. (1973), "Analysis and design of framed tube structures for tall concrete buildings", Response of Multistory Concrete Structures to Lateral Forces, ACI/SP36-3, 39-60.
  17. Newmark, N.M. and Hall, W.J. (1973), "Procedures and criteria for earthquake resistant design", Proceedings of the Workshop on Building Practices for Disaster Mitigation, National Bureau of Standards Building Science Series 46, Boulder Colorado, 209-236.
  18. Park, R. and Paulay, T. (1975), Reinforced Concrete Structures, John Wiley & Sons.
  19. Schuster, N.D., Ventura, C.E., Felber, A. and Pao, J. (1994), "Dynamic characteristics of a 32-story high-rise building during construction", Proceedings of Fifth U.S. National Conference on Earthquake Engineering, Chicago, Ill, 701-710.
  20. Stephen, R.M., Wilson, E.L. and Stander, N. (1985), "Dynamic properties of a thirty-story condominium tower building" , Earthquake Engineering Research Center, Report No. EERC-85/03, Berkeley, CA.
  21. Taoka, G. (1981), "Damping measurements of tall buildings", Proceeings of the Second Specialty Conference on Dynamic Response of Structures: Experimentation, Observation, Prediction, and Control, ASCE, Atlanta, Georgia, 308-321.
  22. Trifunac, M.D. (1970), "Ambient vibration of a thirty-nine story steel frame building", Earthquake Engineering Research Laboratory, EERL 70-02, Pasadena, Calif.
  23. Trifunac, M.D. (1970), "Wind and microtremor induced vibration of a twenty-two story steel frame building," Earthquake Engineering Research Laboratory, EERL 70-01, Pasadena, Calif.
  24. Ward, H.S. and Crawford, R. (1966), "Wind induced vibrations and building modes", Bulletin of Seismological Society of America, 56, 793-813.
  25. Wood, S.L., Stark, R. and Greer, S.A. (1991), "Collapse of eight-story RC building during 1985 Chile Earthquake", Journal of Structural Engineering, ASCE 117(2), 600-619. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:2(600)
  26. Yagi, S., Yoshioka, K., Eto, H. and Nishimura, K. (1990), "Seismic design of a 41-story reinforced-concrete tube structure", Proceedings, 4th World Congress, Tall Buildings: 2000 and Beyond, Council on Tall Buildings and Urban Habitat, Hong Kong, 1123-1137.

Cited by

  1. Classes of exact solutions for several static and dynamic problems of non-uniform beams vol.12, pp.1, 2001, https://doi.org/10.12989/sem.2001.12.1.085
  2. A technique to avoid aspect-ratio locking in QUAD8 element for extremely large aspect-ratios vol.37, pp.6, 1999, https://doi.org/10.12989/sem.2011.37.6.633