• Title/Summary/Keyword: Stand types

Search Result 248, Processing Time 0.025 seconds

Classification of Quercus mongolica Stand Types at Mt. Joongwang, Kangwon-Do and Determination of Proper Future Tree Density for Forest Tending Work (중왕산(中旺山) 지역(地域) 신갈나무림(林)의 임분형(林分形) 구분(區分) 및 육림작업(育林作業)에 적절(適切)한 미래목(未來木) 본수(本數)의 결정(決定))

  • Choi, Seon Deok;Lee, Don Koo;Ma, Sang Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.4
    • /
    • pp.631-641
    • /
    • 1998
  • The objectives of this study were 1) to classify the types of Quercus mongolica stands at Mt. Joongwang and compare their quality, and 2) to determine the proper future tree number of Q. mongolica per ha and the appropriate distance between the future trees. The results from this study were as follows : Q. mongolica stands at Mt. Joongwang was classified into four types, pure Q. mongolica stand as stand type I, Q. mongolica - hardwood stand as stand type II, Q. mongolica - Pines densiflora stand as stand type III, Hardwood - Q. mongolica stand as stand type IV, according to mixture rate in stand volume. Stand type IV showed the best quality stem of Q. mongolica among the stand types, and the stem quality of Q. mongolica in Q. mongolica stand mixed with hardwood as stand types II and IV was better than those in pure Q. mongolica stand as stand type I and in Q. mongolica - P. densiflora stand as stand type III. If the management goal for Q. mongolica stand is to produce its high quality-timber, it is desirable to sustain proper mixture rate of Q. mongolica with another hardwoods. The proper number of future trees in pure Q. mongolica stand as stand type I was 122trees/ha and reasonable distance between the future trees was 9.15m. The distance between future trees in other stand types was 7.2m to 9.3m for stand types II and IV, while 8.0m for stand type III. Thus, the classification of Q. mongolica stand type based on stand character and maturity, and proper stem number of future tree and optimum distance between future trees would be a useful forest tending work.

  • PDF

The Influence of Shoes with Different Heels on Movement of Lower Limb Joints during Sit-to-stand (일어서기 동작 시 발 뒷굽의 형태가 하지 관절 움직임에 미치는 영향)

  • Kim, Yun-Jin;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.2
    • /
    • pp.117-125
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate changes in movement strategies of lower limb joints depending on the type of heel during sit-to-stand. Methods: Twenty healthy females participated in this study. All subjects performed sit-to-stand three times each with three different types of heels - bare feet, 9 cm high-heeled shoes, and unstable shoes. Trails were conducted in random order. Three-dimensional motion analysis systems were used for collection and analysis of the kinematic data of lower limb movements. Results: Results of this study showed kinematic differences in pelvis, hip joints, knee joints, and ankle joints during sit-to-stand based on the type of heels. At the initial sit-to-stand, hip joint flexion, knee joint flexion, ankle joint flexion, and ankle joint inversion showed significant differences. The maximal angles of hip joint flexion, hip joint adduction, knee joint flexion, ankle joint flexion, and ankle joint inversion were significantly different, while hip joint adduction, pelvic forward tilt, hip joint rotation, knee joint flexion, ankle joint flexion, and ankle joint inversion differed significantly during the terminal of sit-to-stand. Conclusion: Therefore, the type of heel played an important role in selection of lower limb movements during sit-to-stand which were essential parts of daily life movements.

Influencing Degree to the Air Temperature of Stratification in the Urban Green Space (도시녹지의 계층구조가 기온에 미치는 영향)

  • 윤용한;김원태
    • Asian Journal of Turfgrass Science
    • /
    • v.16 no.2
    • /
    • pp.107-114
    • /
    • 2002
  • In this study, We measured air temperature in a vegetated area to investigate if stand types and height affect air temperature. With the measured data, we analyzed the relation-ships between air temperature vs. ground cover type, vegetated area, stand structure, stand density, and tree volume by regression analysis. The results show that the paved area and open field have higher air temperatures than the vegetated area and water-related areas. Among the stand types, the stand with overstory and sub-overstory showed relatively low are temperature. The stand with overstory had lower air temperature than the stand with sub-overstory. Increasing stand density was effective for lowering air temperature.

The Comparison of 'Knowledge of Result' and 'Knowledge of Performance' in the Children with Cerebral Palsy

  • Lee, Hye-Young;Lee, In-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.81-84
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the effect of 'knowledge of result' and 'knowledge of performance', two types of extrinsic feedbacks, during the sit-to-stand movement in children with hemiplegic cerebral palsy. Methods: A total of ten children with hemiplegic cerebral palsy (ages 8 to 12 years) were recruited for the study. Subjects with hemiplegic cerebral palsy performed sit-to-stand movement in front of a mirror. Their performance was supervised and revised for normal movement by a pediatric physiotherapist. In the knowledge of the result, subjects performed sit-to-stand using a chair with an armrest in their mind with normal movement. In the knowledge of performance, subjects performed sit-to-stand under verbal instructions. Randomized cross over trials were used in this study. Main outcome measurements were as follows: mediolateral speed, anteroposterior speed, velocity moment, extent in mediolateral direction, extent in anteroposterior direction, and vertical distance of the center of pressure. Results: The mediolateral speed and extent of center of pressure was higher for 'knowledge of performance' in comparison with the other type of extrinsic feedbacks (p<0.05). The other parameters, including anteroposterior speed and extent, and vertical speed of the center of pressure, did not differ between the two types of extrinsic feedbacks (p>0.05). Conclusion: These findings suggested that training in sit-to-stand movement with 'knowledge of result' may result in better use of extrinsic feedback.

Growth Characteristics of Trees following Different Types of Cutting in Quercus acutissima Stand (상수리나무 임분 내에서 벌채 유형에 따른 조림목의 생장 특성)

  • Shin, Yu-Seung;Song, Sun-Hwa;Yang, A-Ram;Hwang, Jaehong;Park, Yong Mok
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1075-1083
    • /
    • 2014
  • The objective of this study was to evaluate the effect of cutting types on microclimate and growth characteristics of afforested tree in Quercus acutissima stand after different types of cutting. The difference in temperature reaching $5.2^{\circ}C$ was shown in between clear cutting and selective cutting treatments. On July and August days with temperatures more than $35^{\circ}C$ often appeared in clear cutting stand. The values of VPD in July and August were higher than those in other months. Maximum VPD of 3.99 kPa was shown in clear cutting stand on May 23 as a prolonged rainless days appeared. However, VPD in selective cutting stand always stayed under 3.0 kPa throughout growing season. A higher intensity was shown in clear cutting and strip clear cutting stands, reaching to more than $1,600{\mu}mol\;m^{-2}s^{-1}$ at midday on early August, while that in selective cutting stand stayed about 1,500. In relative growth rate selective cutting stand showed a significantly higher relative growth rate in plant height than those in other cutting stands (p<0.05). The number of leaf in current-year branches significantly increased in selective cutting stand, whereas no increase was shown in clear cutting and strip clear cutting stands (p<0.05). In addition, relative elongation rate of current year branch also showed higher values in selective cutting stand compared with that in strip clear cutting stand (p<0.05). However, leaf mass per unit area (LMA) was higher in order of strip clear cutting, clear cutting, and selective cutting stands. From these results it is concluded that environmental conditions in clear cutting and strip clear cutting stands during growing season are more stressful to afforested tree species, resulting in lower relative growth in plant height, elongation of current-year branches, and leaf number per branch compared with those in selective cutting stand. Consequently, more data must be accumulated in the field to find out best cutting type in plantation considering the adaptational characteristic of each tree species varies with species and life span of tree is long.

A Review of Forest Development Patten by the Length of Protection Period in Gangwondo Baekdudaegan Mountains (강원지역 백두대간 산림의 보호기간에 따른 임분 발달 양상 검토)

  • Chung, Sang Hoon;Hwang, Kwang Mo;Lim, Seon Mi;Kim, Ji Hong
    • Journal of Forest and Environmental Science
    • /
    • v.30 no.1
    • /
    • pp.133-144
    • /
    • 2014
  • This study was carried out to review the pattern of forest stand development for six Gangwondo Baekdudaegan Mountains which experienced different type and duration of intensive legal protection. Vegetation data from point sampling method were employed to classify community types by cluster analysis on the basis of the importance values of canopy tree species for the study areas. The names of classified communities were given by the composition of dominant tree species. The communities were also compared one another in terms of stand structure by species diversity index. The results indicated that National Parks (Seoraksan and Odaesan) had greater proportion of mixed mesophytic forest type which was supposed to progress further forest succession process so as to have more complex and diversified stand structure. On the other hand, ordinary forest areas (Seokbyeongsan and Deokhangsan) had greater proportion of the forest types which was dominatively composed of Quercus mongolica and Pinus densiflora. The forest types with large amount of these two species would tend to develop for relatively short period of time of 40-50 years after artificial disturbances. Hyangnobong of Natural Protection Area and Hambaeksan of Natural Ecosystem Conservation Area showed intermediate stand development pattern in between National Parks and ordinary forest areas. The period of intensive legal protection of the forest area was positively correlated with species diversity index (R=0.736), and noted that the forest which received intensive protection regulation for longer period tended to show more complex and diversified stand structure.

Analysis Methology of Detailed Stand Age Classes in Forest Type Map (임상도 작성시 정밀 영급분석기법 연구)

  • Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.647-655
    • /
    • 2008
  • The purpose of the study is to find the problems related to the current state of the stand age classes and the method of calculating it defined in the existing forest type map and propose the more accurate method of calculating the stand age classes. The object for the study was selected as the forest scattered around the Geesan village Paju city in Kyunggi province. For the accurate method of calculating the stand age classes, such items as, the type of actual vegetation, establishment of grid-type standard area scaled down at the level of the 5% of the actual area, the types, number, DBH and age of tree found by the plots, were investigated. It was found out actual vegetation was divided into the total 24 types and the 20 types of them belonged to the growing tree areas. As the plots, the 125 places(unit area: $400m^2$) were established the types of the trees found were distributed in the range where the minimum was 1 type, the maximum was 9, the mean was $4.4{\pm}1.5$, and the mode was 4 types. The number of the trees found was distributed in the range where the minimum was 17, the maximum was 125, the mean was $4.4{\pm}1.5$, and the mode was 70. In the DBH, the minimum was 6 cm, the maximum was 30 cm, the mean was 13 cm and the mode was 10 cm. As the result of measuring the age of the 5 trees corresponding to the value of the mode in DBH, selected among the dominant species by the plots, less than 20 years was 17 places, the 115 places were included in the range from 21 to 30 years, and more than 31 years was the 6 places.

Analysis of Texture Information with High Resolution Imagery for Characterizing Forest Stand

  • KIM T. G.;LEE K. S.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.14-16
    • /
    • 2004
  • Although there have been wide range of studies to characterize forest stands based upon spectral information of satellite image, it was not fully understood the texture information of forest stand using high resolution data. The objective of this study is to evaluate several texture measures for characterizing forest stand structure, such as species composition, diameter at breast height(DBH), stand density, and age. High resolution IKONOS satellite imagery data were acquired in August 200 lover the forested area near Ulsan, Korea. Primary forest types were plantation pine, mixed forest, and natural deciduous forest of stand age ranging from 10 to 50 years old. Several GLCM-based texture measures were compared with forest stand characteristics. In overall, a texture measure (contrast) calculated using red band were better to differentiate species and age group than other texture measures and near infrared bands.

  • PDF

Influence of Vegetaton Type on the Intensity of Ammonia and Nitrogen Dioxide Liberation from Soil (토양으로부터 휘발되는 암모니아와 이산화질소의 소실에 대한 식피형의 영향에 대하여)

  • 김천민
    • Journal of Plant Biology
    • /
    • v.14 no.3
    • /
    • pp.43-46
    • /
    • 1971
  • Losses of nitrogenin the gaseous form were determined with closed systems in the filed under different vegetation types. Ammonia volatilization was greatest from the pine stand, and least from the sod stand, and was greatly reduced in all three sites in the rainy season due to the low temperature. There were only insignificant differences in the nitrogen dioxide volatilization from the soil of the three vegetation types. Losses of ammonia and nitrogen dioxide at various soil depth also showed little variation. Evidently the microbial activity responsible for the $NO_2$ loss was relatively unaffected by the changes in temperature and soil moisture content during the investigation.

  • PDF

A Study on the Facility Layout and Signal-fire Stand of Border Signal-fire in Chosun Dynasty (조선시대 연변봉수(沿邊烽燧)의 배치형식 및 연대(煙臺)에 관한 연구)

  • Lee, Chul-Young;Yoon, Jae-Woong
    • Journal of architectural history
    • /
    • v.15 no.5
    • /
    • pp.41-56
    • /
    • 2006
  • Signal fire was a communication system which deliver urgent news by smoke and light. It informed the condition of the border to the central government and the military base rapidly. This research was to analyze the border signal-fire which is the main facility of military protective duty for safety of sea side in chosun dynasty. The results of this research were described separately as follows. 1. The border signal-fire has three types of facility layout, The majority was one-site, near two-site, separate type. The majority was near two-site type. 2. Plan configuration of signal-fire stand which is separated with circle, oval, round-rectangular and rectangular type roughly was constructed with circle type generally. Four types of signal-fire stand was observed in southern and western sea side impartially. However, in eastern side, circle type of signal-fire stand was mainly found. Therefore, regional characteristics could be considered partially. 3. The height of signal-fire stand was about 8~10m. The diameter of combustion chamber on the signal-fire stand was 2~3m in circle type, and the dimension of rectangular type was about $1.9{\times}1.9{\sim}3.2{\times}3.0m$. 4. Building base that protect ground moisture and infilteration of rainfall was found in 10 border singal-fire, the height of it was about 0.3m~2.5m.

  • PDF