• Title/Summary/Keyword: Stage equipment

Search Result 608, Processing Time 0.022 seconds

Simulation of Particle Behaviors within a Multi-stage Impact Crusher using Discrete Element Method (이산요소법을 이용한 다단 임팩트 파쇄기 내 입자 거동 모사)

  • Yu, Myoungyuol;Lee, Hoon
    • Resources Recycling
    • /
    • v.27 no.3
    • /
    • pp.86-92
    • /
    • 2018
  • The amount of construction waste generated is steadily increasing every year, and the Law for Promotion of Recycling is enacted. However, it is difficult to use it as a recycled aggregate for concrete, which is presented in the quality standard of recycled aggregate with high water uptake and low density due to low separation of aggregate between concrete and cement paste. Therefore, in this study, a multi-stage impact crusher was used to remove mortar, which is essential for improving the quality of recycled aggregate. In analyzing the characteristics of the equipment, the spectrum of energy generated in each part between the particle and the equipment was calculated by using DEM. In order to generate an effective separation phenomenon, it was confirmed that the operation condition of 900 RPM was appropriate based on the ratio of the number of collisions (L/H) of the low energy group (L) to the number of collisions of the high energy group (H).

The effect of 100KHz PWM LED light irradiation on RAT bone-marrow cells (100kHz PWM LED 광조사가 백서 골수세포에 미치는 영향)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Kim, Young-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Yu, Seong-Mi;Lee, Hee-Gap;Kim, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.512-513
    • /
    • 2008
  • The study examined what effects 100kHz PWM LED light irradiation causes to bone marrow cells of SD-Rat when LED characterized cheap and safe is used onto the light therapy by replacing the low 1evel laser. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Consequent1y, the current value could be controlled by the change of 1eve1 in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of Rat bone marrow cells was verified in 100kHz PWM LED light irradiation group as compared to non-irradiation group.

  • PDF

Performance Status of Sanitary Management of School Food Service in the Jeonnam Area (전남지역 학교급식의 위생관리 실태)

  • 고무석;정난희;이전옥
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.51-67
    • /
    • 2004
  • This study analyzed the effects of nutrition technicians' hygiene education on cooking workers' performance of hygiene management in order to ensure the security of school meals. The situation of cooking workers' disposition in subject schools was elementary school(51.1%) and middle school(48.9%) and the type of meals was rural area type(54.2%), urban type(36.5%). and island and isolated area type(9.3%). The methods of meals management were single cooking(88.2%) and joint cooking and management(11.8%). The type of distributing meals was distributing in a dining room(93.5%), in a classroom(3.7%), and in both dining room and classroom(2.8%). Nutrition technicians' employment form included regular(53.5%) and daily(88.2%). Their education was junior college graduate(50.2%), university graduate(44.8%). and graduate school students(5.0%). Cooking workers' employment form included daily(88.2%) and regular (11.1%). suggesting that most were regular. Most cooking workers(77.4%) had at least high school certificate. Regarding the situation of cooking workers' disposition in subject schools, the number of student per one cooking worker was found as 91-120(37.2%), 61-90(22.6%). 60 and under(21.l %). 121-15006.7%). and 151 and over(2.5%). Cooking workers' level of performance of hygiene management was post-working stage(66.37/75 marks), pre-working stage(64.22/75 marks). and working stage(20.34/25 marks), The counting of meals articles in a pre-working stage(20.34/25 marks). temperature and required time in a working stage(18.78/25 marks), and machinery equipment and hygiene in a pre-working stage(21.40/25 marks) showed lowest of performance, which suggest poor service of hygiene. Cooking workers' performance of hygiene management by working stage showed the significant difference with school class(p<.001), type of schools with meals(p<.05). state of cooking workers' employment(p<.001), and cooking worker's disposition(p<.05). A working stage showed the significant difference with type of schools with meals(p<.05). A post-working stage showed the significant difference according to type of schools with meals(p<.05), and the methods of meals management(p<.05), and cooking workers' disposition(p<.05). In the execution of hygiene education, individual hygiene was highest(94.8%), followed by the management of machinery equipment and tools(89.7%), food poisoning and microorganism(94.7%), and the method of food treatment(76.4%). A yearly plan of hygiene education included established(83.9%) and not established(l6.1%). Regular education included not executed(25.1%), 2-3 times a month(l6.1%), and more than 4 a month(4.0%) and occasional education was not executed(57.0%), 1-3 times a month(26.3%), and more than 4 a month(l5.7%). In the methods for hygiene education, oral education(95.7%) was used most, followed by demonstration(10.5%), poster/photo(10.5%), video/slide(3.7%), and computer(3.7%). Frequency of improvement and complement of hygiene education included once a month(56.3%), once a year(20.7%), by quarter(l1.5%), and every six months(1l.5%). Newspaper was used most in materials of hygiene education, followed by internet, TV, nutrition technician's reeducation, information exchange between members, educational office's training, and reference book, and educational office's material. and symposium. Cooking workers' assessment of the effect of hygiene education was conducted through observation(56.8%), check table(l5.2%), question(l4.0%), and examination(14.0%). The reason of cooking workers' low level of performance included habitual custom(53.9%), lack of understanding(20.4%), overwork(l4.6%), and lack of knowledge(l1.l%) and the reason of difficulty in hygiene education included lack of time(55.3%), lack of understanding(27.6%), lack of knowledge and information(8.7%), and lack of budget(48.0%).

  • PDF

A Study on the Methods of Building Tools and Equipment for Digital Forensics Laboratory (디지털증거분석실의 도구·장비 구축 방안에 관한 연구)

  • Su-Min Shin;Hyeon-Min Park;Gi-Bum Kim
    • Convergence Security Journal
    • /
    • v.22 no.5
    • /
    • pp.21-35
    • /
    • 2022
  • The use of digital information according to the development of information and communication technology and the 4th industrial revolution is continuously increasing and diversifying, and in proportion to this, crimes using digital information are also increasing. However, there are few cases of establishing an environment for processing and analysis of digital evidence in Korea. The budget allocated for each organization is different and the digital forensics laboratory built without solving the chronic problem of securing space has a problem in that there is no standard that can be referenced from the initial configuration stage. Based on this awareness of the problem, this thesis conducted an exploratory study focusing on tools and equipment necessary for building a digital forensics laboratory. As a research method, focus group interviews were conducted with 15 experts with extensive practical experience in the digital forensic laboratory or digital forensics field and experts' opinions were collected on the following 9 areas: network configuration, analyst computer, personal tools·equipment, imaging devices, dedicated software, open source software, common tools/equipment, accessories, and other considerations. As a result, a list of tools and equipment for digital forensic laboratories was derived.

A Study on CO2 Emissions to Establish a LCI DB at the Disuse Stage (폐기단계에서 LCI DB구축을 위한 CO2 발생량에 관한 연구)

  • Choi, Doo-Sung;Park, Jin Jong;Chun, Hung Chan
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.103-110
    • /
    • 2013
  • This study aims to calculate the $CO_2$ emissions by the properties of construction waste to establish a LCI DB of construction waste generated at the disuse stage. The $CO_2$ emissions from apartment houses was calculated by calculating the energy consumptions by treatment steps to calculate the $CO_2$ emissions by the treatment steps of construction waste. As a result of analyzing the $CO_2$ emissions from a total of 27 complexes, maximum 46,791g-$CO_2/m^2$, minimum 34,893g-$CO_2/m^2$ and average 38,713g-$CO_2/m^2$ were generated, and were varied by the quantity of construction waste in general, but were affected by the transportation distance in case of transportation steps as well. As a result of analyzing the $CO_2$ emissions by the properties of construction waste, average 19,815.50g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage in case of construction wastes, and 1.72g-$CO_2/m^2$ was generated, the lowest, during reclamation. In case of combustible waste, average 11,495.63g-$CO_2/m^2$ was generated, the highest, from the example complex during incineration of wastes, and 21.48g-$CO_2/m^2$ was generated, the lowest, at the waste transportation stage. In case of noncombustible waste, average 522.43g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage, and 1.07g-$CO_2/m^2$ was generated, the lowest, at the transportation stage. In case of other construction wastes, average 645.42g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage, and 47.38g-$CO_2/m^2$ was generated, the lowest, at the middle treatment stage.

Application of Discrete Event Simulation on Tunnel Muck Hauling Operations (터널 버력처리 공정의 시뮬레이션 적용성에 관한 연구)

  • Kim, Kyoung-Min;Seo, Hyeong-Beom;Hwang, Ho-Jung;Kim, Kyong-Ju
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.1 s.35
    • /
    • pp.141-149
    • /
    • 2007
  • Simulation has considerable potential as the tool of construction management, but in the case of domestic, it is at an early stage applying simulation to micro-process assesment. For applying simulation to the construction process, much effort is needed to collect input data and to build the model including the characteristics of site. This study introduces the methodology to collect operation data of construction equipment and build the simulation model, then verifies the model with the operation data. In addition, this study identifies main factors to determine the cycle time of the muck hauling system so that it suggests the method of construction process planning through operation and combination of construction equipments.

Application of the Geothermal Hybrid System for Huge Size Common Structures with Heating & Cooling System (지열 Hybrid System 개발을 통한 대형 공동구조물 지열에너지 적용성 평가)

  • Park, Si-Sam;Na, Sang-Min;Park, Jong-Hun;Rhee, Keon-Joong;Kim, Tae-Won;Kim, Sung-Yub
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.588-591
    • /
    • 2009
  • Ground source heat pump system; GSHPs is close to most practical use for early stage investment cost and energy efficiency in new renewable energies, and currently considered utilizing to the heat and cooling system of a building. Particularly, the case to utilize 'Standing Column well heat source gathering method' in the open standards process to have the excellent capability of gathering geothermal source is increased. But the research for the optimal design technology and the assessment of a pollution level of the ground to utilize a single well for gathering geothermal is insignificant and the design is insufficient. The heating and cooling system and the equipment to utilize a large size residential development to have over 1000 households have not developed yet. Therefore, our company developed 'geothermal hybrid system' which can construct the heat and cooling system using geothermal energy for a large size residential development of over 1000 households and conducted the evaluation of economic feasibility. Moreover we developed automatic equipment for gathering geothermal source and PLC (Programmable logic controller) to have optimal efficiency and FCU (fan coil unit) considering the floors of large size apartments.

  • PDF

Validation of Availability, Maintainability and Safety for Subway Elevating Equipment (도시철도 승강설비의 가용성, 유지보수성 및 안전성 입증)

  • Lee, Hwan-Deok;Jung, Won
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.272-279
    • /
    • 2016
  • Purpose: In order to fulfill the RAMS (Reliability Availability Maintainability and Safety) requirements in Korean railway systems, specific target metrics should be measured and met the requirements when ordering a new system. This paper presents a procedure to predict and demonstrate the availability, maintainability and safety of subway elevators, escalators and PSD (platform screen doors) systems. Methods: The system manufacturer predicts availability and maintainability with lab and field tested data. After installation, availability and maintainability are demonstrated based on the actual operational data. The data was collected from the FRACAS (Failure Report and Corrective Action System). Results: Methods and process of assessing and analyzing the availability, maintainability and safety are presented for elevating services and PSD systems. The data obtained through the actual operation of the equipment is analyzed and maintained to predict the RAMS based on the component and system level failure data acquired. Conclusion: This study presented an application using IEC 62278 and operational data which can be used in the design and development stage to achieve the RAMS target value of the subway elevators, escalators and PSD systems.

Liner Analysis of IMV Proportional Flow Control Valve Static Characteristics (IMV 비례 유량제어밸브 정특성 선형해석)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.56-64
    • /
    • 2019
  • Recently, as the environmental regulation for earth moving equipment has been tightened, advanced systems using electronic control have been introduced for energy savings. An IMV(Independent Metering Valve), which consists of four 2-way valves, is one of the electro-hydraulic control systems that provides more flexible controllability and potential for energy savings in excavators, when compared to the conventional 4-way spool valve system. To fully realize an IMV, a two-stage bi-directional flow control valve which can regulate the large amount of flow in both directions, should be developed in advance. A simple design that allows proportional flow control to apply the pilot pressure from the current-controlled solenoid to the spring loaded flow control spool and thus valve displacement, is proportional to the solenoid current. However, this open-loop type valve is vulnerable to flow force which directly affects the valve displacement. Force feedback servo of which the position loop is closed by the feedback spring which interconnects the solenoid valve and flow control spool, could compensate for the flow force. In this study, linearity for the solenoid current input and robustness against load pressure disturbance is investigated by linear analysis of the static nonlinear equations for the IMV proportional flow control valve with feedback spring. Gains of the linear system confirm the performance improvement with the feedback spring design.

Simulation Based Production Using 3-D CAD in Shipbuilding

  • Okumoto, Yasuhisa;Hiyoku, Kentaro;Uesugi, Noritaka
    • International Journal of CAD/CAM
    • /
    • v.6 no.1
    • /
    • pp.3-8
    • /
    • 2006
  • The application of three-dimensional (3-D) CAD has been popularized for design and production and digital manufacturing has been spreading in many industrial fields. By simulation of the production process using 3-D digital models, which are the core of CIM (Computer Integrated Manufacturing) system, the efficiency and safety of production are improved at each stage of work, and optimization of manufacturing can be achieved. This paper firstly describes the concept of "simulation based production" in shipbuilding and also digital manufacturing; the 3-D CAD system is indispensable for effective simulation because ship structure is three dimensionally complex. By simulation, "computer optimized manufacturing" can be possible. The most effective fields of simulation in shipbuilding are in jobs where many parties have to cooperate, while existing two-dimensional drawings are hardly observed the whole structures due to interference between structures or equipment of complex shape. In this paper some examples of the successful application in IHIMU (IHI Marine United Inc.) are shown: assembly of a pipe unit, erection of a complex hull block, carriage of equipment, installation of a propeller, and access in an engine room.