• Title/Summary/Keyword: Square pulse

Search Result 259, Processing Time 0.024 seconds

Development of Ultrasonic Pulse Compression Using Golay Codes (Golay 코드를 사용한 초음파펄스압축법 개발)

  • Kim, Young-H.;Kim, Young-Gil;Jeong, Peter
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer. However, these systems are limited in pulse energy. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse causes decrease of the resolution. Using the pulse compression, a long pulse of pseudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was implemented into an ultrasonic system. Golay code was used as a pseudorandom signal in this system, since pair sum of autocorrelations has no sidelobe. The equivalent input pulse of the Golay code was derived to analyze the pulse compression system. Throughout the experiment, the pulse compression technique has demonstrated for its improved SNR(signal to noise ratio) by reducing the system's white noise. And the experimental data also indicated that the SNR enhancement was propotional to the square root of the code length used. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  • PDF

Relations between 10 Primary Pulse Conditions Based on Doctors' Pulse Diagnoses (전문가 진단에 기반한 10대 맥상들 간의 연관성에 대한 연구)

  • Lee, Jae-Chul;Kang, Nam-Sik;Lee, Hae-Jung;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.6
    • /
    • pp.1077-1081
    • /
    • 2010
  • In this work, we report the diagnostic relations among some primary pulse conditions such as the floating/sunken, deficient/forceful, large/fine, and the long/short pulses. For this purpose, we carried out a clinical test, in which 11 Oriental medical doctors had participated to diagnose the pulses for 1566 healthy subjects. The subjects were divided into 11 subgroups and each subgroup was allocated to an individual doctor. It resulted in that, for 847 subjects (54%), two or more than two pulse conditions were felt simultaneously, for which we counted the frequency of the pairs of the pulse conditions. For the statistical analysis, we used a Chi-square test. As a result, at high frequency, the forceful, large, and the long pulses were diagnosed in pairs or in their triplet, and a similar close relation was found between the deficient, fine, and the short pulses. The pairwise diagnoses of the pulse conditions between the forceful, large, and the long pulses, and between the deficient, fine, and the short pulses imply their close relatedness in clinics. This result is supported by the theory of deficiency/excess syndromes. Moreover, we show that the close relatedness among the pulse conditions can be understood in terms of the geometric features of the radial artery near the prominent bone. This is the first work which reports the relatedness between the primary pulses by an objective clinical test.

Crosstalk Analysis accrording to Characteristics of Pulse Signal on the Multi Microstriplines unsing the SPICE (SPICE를 이용한 마이크로스트립 다중 전송선로에서 펄스 특성에 따른 선로의 누화특성 해석)

  • 김기래;이영철
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.79-85
    • /
    • 1999
  • The propagation properties of the high speed pulse signal in time domain using the equivalent circuits for the analysis by SPICE on the coupled microstrip lines are investigated. In this paper, the SPICE program is used for the crosstalk analysis on the coupled microstrip lines. The results of crosstalk of coupled microstrip lines compared to one by Branin and FDTD method. And the near-end and far-end crosstalk on coupled lines are analyzed for the square pulse and trapezoidal pulse. The results of this paper are apply To the determination for the geometric structure and the frequency of signal pulse in design of MIC and MMIC by the CAD program.

  • PDF

A Study on Weld Defect and Their Alternatives during Lap Welding of AZ31B Magnesium Alloy by Pulsed Nd: YAG Laser (Nd:YAG 펄스 레이저를 이용한 AZ31B 마그네슘 합금의 겹치기 용접에서 발생하는 용접결함과 그 대책에 대한 연구)

  • Kim, Jong-Do;Lee, Jung-Han;Kim, Young-Sik
    • Journal of Welding and Joining
    • /
    • v.29 no.3
    • /
    • pp.82-88
    • /
    • 2011
  • With a tendency for the application of thin magnesium alloy plates in portable electronic equipment such as cell phone and notebook PC, there is a requirement to develop a welding technology for the lap welding of these thin magnesium alloy. This paper presents the single pulsed laser welding of AZ31B magnesium alloy. The effects of fiber types and parameters such as peak power and pulse width on laser weldability were investigated. The results show that weld defects, especially solidification crack, were always generated in the weld. These defects couldn't be controlled by the simple square pulse, but could be improved through the application of variable pulse. It is because that variable pulse has effect of solidification delay by dropping peak power gradually.

Development of a Characteristic Point Detection Algorithm for the Calculation of Pulse Wave Velocity (맥파전달속도 계산을 위한 특징점 검출 알고리즘 개발)

  • Lee, Lark-Beom;Im, Jae-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.902-907
    • /
    • 2008
  • Shape of the pulse waveform is affected by the visco-elasticity characteristics of the arterial wall and the reflection waves generated at the bifurcations of arterial branches. This study was designed to improve the accuracy for the extraction of pulse wave features, then proved the superiority of the developed algorithm by clinical evaluation. Upstroke point of the pulse wave was used as an extraction feature since it is minimally affected by the waveform variation. R-peak of the ECG was used as a reference to decide the minimum level, then intersection of the least squares of regression line was used as an upstroke point. Developed algorithm was compared with the existing minimum value detection algorithm and tangent-intersection algorithm using data obtained from 102 subjects. Developed algorithm showed the least standard deviation of $0.29{\sim}0.44\;m/s$ compared with that of the existing algorithms, $0.91{\sim}3.66\;m/s$. Moreover, the rate of standard deviation of more than 1.00m/s for the PWV values reduced with the range of $29.0{\sim}42.4%$, which proved the superiority of the newly developed algorithm.

Effect of Aroma Therapy on the Anxiety, Blood Pressure and Pulse of Uterine Leiomyoma Patients before Surgery (아로마 향기요법이 자궁근종 여성의 수술전 불안, 혈압 및 맥박에 미치는 효과)

  • Oh, Jin-A;Kim, Hyun-Jin;Park, Jung-Hyun
    • Women's Health Nursing
    • /
    • v.14 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: The study was performed to evaluate effects of aroma therapy on the anxiety, blood pressure and pulse of uterine leiomyoma patients before surgery and to apply it as the actual nursing intervention. Method: From Aug1st to Nov. 30th, 2007, the experimental group (n=30) and the control group (n=30) were selected in 1 hospital, Busan. Lavender and Bergamot oil mixed together at a 3:2 ratio was applied to the experimental group two times at 8-9 pm the day before surgery and twice 30 minutes before the surgery. Anxiety, VAS, blood pressure, and pulse were measured to evaluate the effects of aroma therapy. The data analysis was done using the SPSS/PC 12.0 program using chi-square test and t-test. Results: Hypothesis 1 was supported. The VAS of the experimental group was lower than control group after aroma therapy. Hypothesis 2 was partly supported. The systolic blood pressure and pulse of experimental group was significantly decreased, but diastolic blood pressure wasn't difference. The VAS, systolic blood pressure and pulse of control group were increased. Conclusion: The study verified that the aroma therapy is a very effective nursing intervention that can reduce anxiety before surgery. It is recommended to apply aroma therapy actively to patients experiencing anxiety before surgery procedure.

  • PDF

A Basic Study for the Development of Electrio-Cell Fusion Device and Performance-Improvement (전기적 세포융합기의 제작 및 성능 개선을 위한 기초 연구)

  • 이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Electrofusion of cabbage protoplasts was performed with a developed equipment which consists of a parallel wire electrode, a AC field generator, and a pulse generator. Exposure of protoplasts to an alternating current field of 450 KHz causes attraction to each other which leads to chains of protoplasts extending from the electrode. Intra-specific protoplast fusion was effectively induced within the pearl chains by the additional application of a single high-intensity DC square wave pulse of 1 KV/cm for 1-3 msec. To improve the performance, micro fusion electrode fabricated from the semiconductor technology and microcontroller based field an, d pulse generator was proposed. The viability of protoplasts after an application of electric field at optimum condition was reduced by only 5 % compared with that of pre-application. A prototype of fusion electrode, which consists of insulator-structure, was successfully fabricated by using photosensitive polyimide.

  • PDF

A Study on the Performance Improvement in Sidelobe Suppression for Pulse Compression of LFM Signal (LFM 신호의 펄스압축에 대한 부엽억제 성능향상 기법연구)

  • Shin, Jeong-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.95-100
    • /
    • 2006
  • The pulse compression technique using Linear FM signal is commonly used for improving the performance of both the detection range and range resolution in radar system. In general, the compressed LFM waveform has relatively large sidelobe level which may prevent a target from being detected when strong jammer or clutter signal is near the target signal. In this paper, we propose a new weighting method which uses the square-root weight to suppress the sidelobe level. Typical applications are missile seekers and tracking radar systems where target tracking range is available prior to the signal processing. By computer simulation, we show that the performance of the proposed method is better than that of the conventional weighting methods in terms of sidelobe suppression.

MM PWM Scheme for High Performance and Harmonic Effects Minimization of VSI-IM Drive System (VSI-IM 구동시스템의 고동작 및 고주파영향 최소화를 위한 MM PWM 방식)

  • Min Soo Kim
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.1
    • /
    • pp.42-48
    • /
    • 1988
  • MM(multimode) PWM(pulse width modulation) Suitable for high performance and harmonic effects minimization of VSI (voltabge source invertetr)-IM (induction motor)drive system is proposed. The approximated optimal, suboptimal and optimal PWM are implemented in the low frequency range, while square wave operation is realized in the hibh frequency range. The pulse width Modulator is capable of generating control signals to a transistorized inverter operating at about 1KHz. All functions except digital comparison have been implemented in softyware making the scheme economical, flexible and reliable. Pulse width modulator is built and tested experimentally. In order to confirm the effectiveness and the reliability of the theoretical proposition, this scheme is applied to 1Hp, Three phase IM. As results, it is concluded that the scheme of MM PWM is superior to other conventional switching scheme through the discussions or analysis carried out on the items such as line-to-line voltage, current and spectrum of current harmonic components observed at the output terminal of inverter, noise level of motor.

  • PDF

Micro Electrochemical Machining of Stainless Steel Using Citric Acid (구연산을 이용한 스테인레스 스틸의 미세 전해가공)

  • Ryu, Shi-Hyoung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.134-140
    • /
    • 2008
  • Micro electrochemical machining (ECM) is conducted on stainless steel 304 using non-toxic electrolyte of citric acid. Electrochemical dissolution region is minimized by applying a few hundred second duration pulses between the tungsten SPM tip and the work material. ECM characteristics according to citric acid concentration, feeding velocity and electric conditions such as pulse amplitude, pulse frequency, and offset voltage are investigated through a series of experiments. Micro holes of $60{\mu}m$ in diameter with the depth of $50{\mu}m$ and $90{\mu}m$ in diameter with the depth of $100{\mu}m$ are perforated. Square and circular micro cavities are also manufactured by electrochemical milling. This research can contribute to the development of safe and environmentally friendly micro ECM process.