  • Field disease incidences of squash virus diseases in Jeonnam province were estimated to be 76.1% and of delayed planting on August-September (retarding culture) and on February-March (semi-forcing culture) on glass house were 55.0% and 0%, respectively, in 2000. Disease incidences of individual squash plant within a field were 100% and 3.6%, respectively, in wild culture and retarding culture. Total of 61 samples suspected to be infected with viruses were collected in 2000 and tested by RT-PCR using specific oligonulceotide primer sets designed for the detection of Cucumber green mottle mosaic virus (CGMMV), Kyuri green mottle mosaic virus (KGMMV), Zucchini yellow mosaic virus (ZYMV), Papaya ring spot virus (PRSV), Watermelon mosaic virus (WMV), and Cucumber mosaic virus (CMV). Each specific primer set for WMV, ZYMV, and PRSV amplified expected size of DNA fragments from 16, 10, and 2 samples in wild culture, respectively. Double or triple infection were observed in 7 samples tested. In contrast, each specific primer set for WMV, ZYMV, and PRSV confirmed virus infection from 7, 6, and 6 samples, respectively, in samples collected from semi-forcing culture. Double infection of WMV and PRSV was observed in only one sample. However, no DNA fragment was amplified from RT-PCR using CGMMV, KGMMV, and CMV specific oligonucleotide primer sets indicating no CGMMV, KGMMV, or CMV infection in squash fields in Jeonnam province in 2000.

A study on the Effectivness of Hand-made Paraffin Thyroid Phantom (Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구)

  • Park, Soung-Ock;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.237-243
    • /
    • 2007
  • Phantoms are very necessary for quality assurance of radio nuclides imaging systems to maintain standards and to ensure reproducibility of test. General quality assurance and instrument quality control are essential in every hospital. The human tissue equivalent materials are aluminum, areryl, water and epoxy..etc. It is very important to select optimum equivalant materials for a phantoms in QC. Especially, paraffin is very similar with human soft tissue in X or Gamma-ray physical characteristics and easy to buy with economically. We made a paraffin thyroid phantom and compare with thyroid areryl phantom, also used commercially in practice. Two small size cold spots(3 and 6 mm diameter) and a hot spot(3 mm diameter) embeded in paraffin phantom. And imaged with $^{99m}TcO_4$ by camera for analysis about spatial resolution and noise at the hot and cold spots. We got some results as below : 1. No difference in counting rate and noise between both arcryl and paraffin thyroid phantoms. 2. The best spatial resolution can be seen 6 cm distance between pinhole collimator and thyroid phantoms(arcryl and paraffin). 3. More optimal spatial resolution could acquired in paraffin thyroid phantom. Paraffin is very similar with human soft tissue in atomic number, density and relative absorbtion function, and can be shaped easily what we wanted. So we can recommendation paraffin as quality assurance phantom because its usefulness, economical benefit and purchasability.

  • PDF

Real Time Safety Management Framework at Construction Site based on Smart Mobile (스마트모바일 기반의 실시간 현장안전관리 프레임워크)

  • Park, Moonseo;Kim, Euijun;Lee, Hyun-Soo;Lee, Kwangpyo;Suh, Sang-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.4
    • /
    • pp.3-14
    • /
    • 2013
  • Recently, as the size of construction projects is getting bigger and higher, construction disasters have been being serious such as death, also it is hard to manage efficiently since there are plenty of informations about safety management. Thus on the spot & real time safety management is required and one of the ways to support these needs, conjunction with Information Technology(IT) has been being noticed. Accordingly, Personal Digital Assistant(PDA), Palmtop Computer and Tablet Personal Computer and so on have been adopted. However another inefficient sides are showed up such as limitation of equipment(weight, inconvenience of control and others). Meanwhile, exchanging and processing data are improved at wide area due to advance of mobile communication and introduction of smart mobile, which is a simple and convenient, is a proven at many aspects. In this research, to support effective safety management, the framework is realized in connection with smart mobile with finding the problems of safety management and deriving demands. Two smart mobile applications, which are Safety Management application and Safety Guideline application, enable that safety management in real time, less re-work and using safety information.

Changes of Various Balls Velocity under the Different Surface Conditions after Impact (충돌 후 지면 조건에 따른 다양한 볼의 속도변화에 관한 연구)

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.91-97
    • /
    • 2007
  • The purpose of this study was to investigate the changes of various balls velocity under the different surface conditions after impact. For this study, four different balls were used which are golf ball, tang-tang ball, table tennis ball, and iron ball. And two different types of ground conditions were used which are artificial grass green and glass green. Movements of putter head and ball were recorded with 2 HD video cameras(60 Hz, 1/500s shutter speed). Small size control object($18.5cm{\times}18.5cm{\times}78.5cm$) was used in this study. To transfer the same amount of kinetic energy to the ball, pendulum putting machine was used. Analyzing the process of impact and the ball movement, a putter was digitized the whole movement but the ball was digizited within the 50cm movement. Velocities were calculated by the first central difference method(Hamill & Knutzen, 1995). Putter head velocities were about 112.2cm/s-116.2cm/s at impact. Maximum ball velocities were appeared 0.08s-0.10s after impact no matter what the ground conditions are. Table tennis ball recorded higher ball velocities than the other ball velocities and iron ball recorded the lowest ball velocity in this group. But Table tennis ball was influenced with the frictional force and immediately was decreased at the artificial grass green condition. If an object is received the kinetic energy under the static condition(v=0cm/s), the object recorded the maximum velocity shortly after the impact and then decreased the velocity because of the frictional force. The ball distance from the start position to the peak velocity position is about 6cm-10cm under the 112.2cm/s-116.2cm/s putting velocity with putter. 0.25 seconds later after impact balls were placed 40cm distance from the original position except iron ball. In this study, ball moving distances were too short therefore it was not possible to investigate the reactions after the translational force is disappeared. Rotational force would play a major role at the end of the ball movement. Future study must accept two things. One is long distance movement of ball and the other is balanced ground. Three-piece ball is a good item to investigate the golf ball movement on the different surface conditions.

A Study on "Beijijiufa" ("비급구법(備急灸法)"에 대한 연구(硏究))

  • Shin, Jae-Hyeok;Kim, Jang-Saeng;Kim, Jae-Jung;Lee, Si-Hyeong
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.17 no.2
    • /
    • pp.82-129
    • /
    • 2011
  • "Beijijiufa" is a medical book republished by Sun Ju Qing in 1245. He compiled this book having added "Qizhumajiufa" and "Zhugejingyanbeijiyaofang" to the contents of "Beijijiufa" authored by Wen Ren Qi Nian. In "Beijijiufa" the author described treatment methods making use of moxibustion methods in connection with 22 cases of acute diseases. The author had collected the moxibustion methods used to treat acute diseases, which had been practiced by the medical practitioners of many generations, and quoted total 13 medical men's practices. In the book, the greatest parts of details were quoted especially from the writings of Sun Si Miao and Ge Hong, and this shows that the medical philosophies of both Sun Si Miao and Ge Hong were reflected onto "Beijijiufa". He had differed on his moxibustion practice: the size of moxa wool, the number of moxibustion treatment, and method of moxibustion for male and female were differed from one another according to the disease. As to the area of moxibustion, he chose the body parts around under four limbs and joints, and mostly used extraordinary acupoints rather than twelve main meridians. In his descriptions of finding meridian points, he did not describe it by its specific name of the reaction point, but explained the location of moxibustion points in detail through pictures. "Qizhumajiufa" is related to moxibustion method and prescriptions to treat surgical diseases, like skin boils or furuncle on the back, etc. He easily explained the method to find the meridian points for moxibustion treatment by using particular way through diagrams and pictures. Eight prescriptions he used were the collections among the historical practices of medical practitioners of many generations for skin boils which showed excellent therapeutic actions. In "Zhugejingyanbeijiyaofang", there are prescribed for 36 disease, also is the records of treatment methods for medical emergency which would be encountered easily in everyday life. As to therapeutic remedies, varied treatment methods, including the treatment by means of pasting and attaching medicinal substance to the spot, the treatment by means of mixing medicinal substance with alcoholic beverage, cleansing method, smoke inhalation remedy etc. were introduced. In "Beijijiufa" moxibustion was regarded as a top priority for treatment of acute disease, and the author strived to present remedies to the readers as easily as possible through 19 pictures. Regarding prescriptions, the author introduced diverse treatment methods with respect to various disease symptoms, and described the method to treat disease symptoms making use of medicinal ingredients which can easily be found in daily life. Likewise, "Beijijiufa" compiled by Sun Ju Qing was intended for clinical practice, and was indeed a medical book having been utilized for treatment of acute diseases in those days.

  • PDF

The Development of 63nm Diode Laser System for Photodynamic Therapy of Cancer (광역학적 암치료를 위한 635nm 다이오드 레이저 시스템 개발)

  • 임현수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.319-328
    • /
    • 2003
  • The purpose of this paper is to develop a medical laser system using the semiconductor diode laser in order to photodynamic cancel therapy as a light source. The ideal light source for photodynamic therapy would be a homogeneous nondiverging light with variable spot size and specific wavelength with stability. After due consideration in this point, in this paper, we used a diode laser resonator of 635nm wavelength. The development laser system have a statistical laser out beam with accuracy control using the constant current control of method and clinic-friendly with compact. In order to protect the diode resonator from the over-current, the rush-current and electrical fault, we specially designed. The most importance therapeutic factor are the radiation mode for cancer therapy. So we developed the radiation mode of CW(Continuous Wave), long pulse, short pulse, and burst pulse and can adjust the exposure time from several milli-second to several minute. The experimental result shows that laser beam power was increased linear from 10mW to 300mW according to the increasing input current and the increasing exposure time. The developed new compact diode laser system have a stability of output power and specific wavelength with easy control and transportable for many applications of PDT.

Development of a Microspot Spectroscopic Ellipsometer Compatible with Atomic Force Microscope (원자힘 현미경 융합형 마이크로스폿 분광타원계 개발)

  • In, Sun Ja;Lee, Min Ho;Cho, Sung Yong;Hong, Jun Seon;Baek, In Ho;Kwon, Yong Hyun;Yoon, Hee Kyu;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.5
    • /
    • pp.201-209
    • /
    • 2022
  • The previously developed microspot spectroscopic ellipsometer (SE) is upgraded to a microspot SE compatible with the atomic force microscope (AFM). The focusing optical system of the previous microspot SE is optimized to incorporate an AFM head. In addition, the rotating compensator ellipsometer in polarizer-sample-compensator-analyzer configuration is adopted in order to minimize the negative effects caused by beam wobble. This research leads to the derivation of the expressions needed to get spectro-ellipsometric constants despite the fact that the employed rotating compensator is far from the ideal achromatic quarter-wave plate. The spot size of the developed microspot SE is less than 20 ㎛ while the AFM head is mounted. It operates in the wavelength range of 190-850 nm and has a measurement accuracy of δΔ ≤ 0.05° and δΨ ≤ 0.02°, respectively. Fast measurement of ≤3 s/sp is realized by precisely synchronizing the azimuthal angle of a rotating compensator with the spectrograph. The microspot SE integrated with an AFM is expected to be useful in characterizing the structure and optical properties of finely patterned samples.

A Study on the Change of Hire Payment Method to Reduce the FFA Basis Risk (FFA 베이시스위험 축소를 위한 용선료 지급기준 변경의 타당성 검토)

  • Lee, Seung-Cheol;Yun, Heesung
    • Journal of Navigation and Port Research
    • /
    • v.46 no.4
    • /
    • pp.359-366
    • /
    • 2022
  • While the Forward Freight Agreement (FFA) has emerged as an effective hedging tool since early 1990, the basis risk and cash flow distortions have been addressed as obstacles to the active use of FFAs. This research analyses the basis risk of FFAs and provides a feasible suggestion to reduce it. Basis risk is divided into timing basis, route basis, size basis, and low liquidity basis. The timing basis is defined as the difference between the physical hire, fixed on the specific contract date and the FFA settlement price, calculated by averaging spot rates for a certain period. Timing basis is considered the worst in eroding the effectiveness of FFAs. This paper suggests a change of hire payment criterion from contract date to 15-day moving average, as a means of mitigating the basis risk, and analyzed the effectiveness through historical simulation. The result revealed that the change is effective in mitigating the timing basis. This study delivers a meaningful implication to shipping practice in that the change of hire payment criterion mitigates the basis risk and eventually activates the use of FFAs in the future.

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source (단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구)

  • Park, Yeonok;Cho, Hyosung;Lim, Hyunwoo;Je, Uikyu;Park, Chulkyu;Cho, Heemoon;Kim, Kyuseok;Kim, Guna;Park, Soyoung
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.215-222
    • /
    • 2015
  • In this work, we performed a proof-of-concept experiment for phase-contrast x-ray imaging (PCXI) based on a single antiscatter grid and a polychromatic x-ray source. We established a table-top setup which consists of a focused-linear grid having a strip density of 200 lines/inch, a microfocus x-ray tube having a focal-spot size of about $5{\mu}m$, and a CMOS-type flat-panel detector having a pixel size of $48{\mu}m$. By using our prototype PCXI system and the Fourier demodulation technique, we successfully obtained attenuation, scattering, and differential phase-contrast images of improved visibility from the raw images of several selected samples at x-ray tube conditions of $90kV_p$ and 0.1 mAs. Further, fusion image (e.g., the attenuation+the scattering) may have an advantage in displaying details of the sample's structures that are not clearly visible in the conventional attenuation image. Our experimental results indicate that single-grid-based approach seems a useful method for PCXI with great simplicity and minimal requirements on the setup alignment.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF