• Title/Summary/Keyword: Spot fire

Search Result 97, Processing Time 0.02 seconds

The Design and Implementation of the Fire Spot Display System Using s Smart Device (스마트 기기를 이용한 화점 표출 시스템의 설계 및 구현)

  • Kim, Sang-Gi;Kim, Dong Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1287-1292
    • /
    • 2018
  • In case of fire, the information related with the fire need to be provided to fire fighters in order to extinguish the fire efficiently. However, existing fire detection systems have the problem not to provide the data of the fire to fire fighters visually. In this paper, we propose the fire spot system using a cloud server to solve this problem. In the proposed system, the sensors installed in a building collect the gas and temperature data and store them into the cloud database using a wireless network. For fire fighters in the field, the details and history of the fire spot are displayed visually on top of the blue print retrieved from the cloud database using a smart device.

Four case of Liver fire.Phlegm-fire Tinnitus treated by Axupuncture Therapy with the Inyeong.the chon spot comparison pulse diagnosis (인영촌구 비교맥진을 통한 간화 담화성 이명환자 침 치료4례)

  • Weon, Young-Ho;So, Woong-Ryong;Lee, Sun-Ho;Kim, Jae-Gwan
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.183-189
    • /
    • 2002
  • Tinnitus is usually due to insufficiency of Kidney-essence, asthenia of the Spleen and Stomach, diseases caused by exogenous pathogenic factor, Liver fire(肝火) by severe stress, Phlegm -fire(痰火) by surfeit of high caloric food and alcoholic liquor. I observed and treated four patients who had been diagnosed with tinnitus of Liver-fire(肝火) and Phlegm-fire(痰火). After I checked the Inyeong(人迎) and the chon spot(寸口), all of their Inyeong were stronger than chon spot. Unbalance of the Inyeong(人迎) and the chon spot(寸口), and symptoms of tinnitus were removed by Acupuncture therapy of three Yang meridians of the hand(手三陽) and three Yang meridians of the foot(足三陽).

  • PDF

Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires (화원에 따른 광전식 연기감지기 반응시간 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

Analysis of Forest Fire Damage Using LiDAR Data and SPOT-4 Satellite Images (LiDAR 자료 및 SPOT-4 위성영상을 활용한 산불피해 분석)

  • Song, Yeong Sun;Sohn, Hong Gyoo;Lee, Seok Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3D
    • /
    • pp.527-534
    • /
    • 2006
  • This study estimated the forest damage of Kangwon-Do fire disaster occurred April 2005. For the estimation, the delineation of fire damaged area was performed using SPOT-4 satellite image and DSM (Digital surface model)/DTM (Digital Terrain Model) was generated by airborne and ground LiDAR data to calculate forests height. The damaged amount of money was calculated in forest area using stand volume formula, combining the canopy height from forest height model and digital stock map. The total forest damage amounted to 3.9 billion won.

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

Validation of MODIS fire product over Sumatra and Borneo using High Resolution SPOT Imagery

  • LIEW, Soo-Chin;SHEN, Chaomin;LOW, John;Lim, Agnes;KWOH, Leong-Keong
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1149-1151
    • /
    • 2003
  • We performed a validation study of the MODIS active fire detection algorithm using high resolution SPOT image as the reference data set. Fire with visible smoke plumes are detected in the SPOT scenes, while the hotspots in MODIS data are detected using NASA's new version 4 fire detection algorithm. The detection performance is characterized by the commission error rate (false alarms) and the omission error rate (undetected fires). In the Sumatra and Kalimantan study area, the commission rate and the omission rate are 27% and 34% respectively. False alarms are probably due to recently burnt areas with warm surfaces. False negative detection occur where there are long smoke plumes and where fires occur in densely vegetated areas.

  • PDF

Experiment study on the Responsiveness of Spot- Type Heat Detector (열 감지기의 응답특성에 관한 시험연구)

  • Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.19
    • /
    • pp.9-16
    • /
    • 1995
  • The spot-type heat detector is a main component of the automatic fire alarm system intended to signal when heat energy is produced in protected area. The most of protected area in our country is installed spot-type heat detector. On this study, the responsiveness to the change of environmental temp. of spot-type heat detec-tor were obtained and analyzed under specified temp., velocity in accordance with the KOFEIS stan-dard. The experiment was carried under the condition with the change of environmental temp. Concluion of this study is as follows : 1. It was confirmed that the responsiveness of rate-of rise heat detector is sensitive to temp. below 10 degrees above zero. The malfunction appeared at 40 degrees above zero and intended performance is disqualified at 50 degrees above zero. 2. The intended performance of fixed-temp. detector which is maintained for the change of envi-ronmental temp. But the responsiveneness is confirmed instability for the change of environmental temp.

  • PDF

Analysis of Burn Severity in Large-fire Area Using SPOT5 Images and Field Survey Data (SPOT5영상과 현장조사자료를 융합한 대형산불지역의 피해강도 분석)

  • Won, Myoungsoo;Kim, Kyongha;Lee, Sangwoo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.2
    • /
    • pp.114-124
    • /
    • 2014
  • For classifying fire damaged areas and analyzing burn severity of two large-fire areas damaged over 100 ha in 2011, three methods were employed utilized supervised classification, unsupervised classification and Normalized Difference Vegetation Index (NDVI). In this paper, the post-fire imageries of SPOT were used to compute the Maximum Likelihood (MLC), Minimum Distance (MIN), ISODATA, K-means, NDVI and to evaluate large-scale patterns of burn severity from 1 m to 5 m spatial resolutions. The result of the accuracy verification on burn severity from satellite images showed that average overall accuracy was 88.38 % and the Kappa coefficient was 0.8147. To compare the accuracy between burn severity and field survey at Uljin and Youngduk, two large fire sites were selected as study areas, and forty-four sampling plots were assigned in each study area for field survey. The burn severities of the study areas were estimated by analyzing burn severity (BS) classes from SPOT images taken one month after the occurrence of the fire. The applicability of composite burn index (CBI) was validated with a correlation analysis between field survey data and burn severity classified by SPOT5, and by their confusion matrix. The result showed that correlation between field survey data and BS by SPOT5 were closely correlated in both Uljin (r = -0.544 and p<0.01) and Youngduk (r = -0.616 and p<0.01). Thus, this result supported that the proposed burn severity analysis is an adequate method to measure burn severity of large fire areas in Korea.