• 제목/요약/키워드: Sphere electrode

검색결과 59건 처리시간 0.033초

평등/불평등 전계 하에서의 제조공기(I-Air) 절연파괴특성 (Breakdown Characteristics of Imitation Air under Uniform Fields and Non-Uniform)

  • 이창욱;이창훈;최은혁;김정배;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1424-1425
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using niform fields(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

연소화염에 의한 수직배치 전극의 플레시오버 특성 (Flashover Characteristics of The Vertical Disposition Electrode Caused by Combustion Flames)

  • 이상우;김충년;지승욱;김인식;김이국;박재용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.208-212
    • /
    • 2001
  • In this paper, characteristics of the ac and do flashover voltages in the vertical air gap of a needle-plane, sphere-plane and rod-plane electrode system were investigated when the combustion flames were present near the high-voltage electrode. As the results of an experimental we found that the reduction of flashover voltages characteristics with the vertical distance caused, in comparison with the no-flame case were about 1/3 times when a short sap d=1[cm] and 2[cm] of the ac voltages were applied. Also, flashover voltages characteristics of the do negative polarity under sphere-plane and rod-plane electrode system with the combustion flame were increased about two times than those of the do positive polarity.

  • PDF

안테나를 이용한 VHF대역에서 전극형태에 따른 방사전자파의 전파특성 (The Propagation Characteristics of Electromagnetic Waves in accordance with electrode shapes at VHF Band Using an Antenna)

  • 김충년;지승욱;이상훈;이광식
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.73-79
    • /
    • 2002
  • 본 논문는 공기중 교류전압원을 이용하여 3종류의 전극부(침대평판전극, 평판대평판전극 및 구대평판전극부)에서 방전시 방사되는 방사전자파를 측정하고, 그 스펙트럼의 특이한 패턴을 나타냈다. 방사전자파의 측정은 스펙트럼분석기와 바이코니칼 안테나를 사용하여 VHF(30~230[MHz])대역에서 측정하였다. 방전개시전압영역일 때, 침대평판전극부인 경우에는 주파수 45, 70, 80[MHz] 대역에서, 평판대평판전극과 구대평판전극부인 경우에는 주파수40[MHz]에서 높은 전계강도를 나타내었다. 그러나 절연파괴전압영역일 때, 방사전자파의 주파수 스펙트럼분포는 전극의 형태에 따라 측정주파수 영역에서 차이를 나타내었다.

연소화염이 플래시오버 특성에 미치는 영향 (The Influence of Flashover Characteristics Caused by Combustion Flames)

  • 김인식;김이국;박재용;이상우;김충년;지승욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.193-197
    • /
    • 2001
  • In this paper, reduction characteristics of the ac flashover voltage in the horizontal air gap of sphere-sphere and needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrodes. The reduction characteristics of ac flashover voltage were discussed with thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that changed by the corona wind and coulomb's force. As the results of an experimental, It was found that the reduction of flashover voltage in sphere-sphere system, in comparison with the no-flame case, are 79.9 [%] for k=0, 82.9 [%] for k=0.5, 87.5 [%] for k=1.0, 85.0 [%] for h=0 [cm], 40.8 [%] for h=5 [cm] and 28.2 [%] for h=9 [cm] when ac voltage is applied.

  • PDF

대기중 연소화염에 의한 교류 플래시오버전압의 저하 특성 (Reduction Characteristics of AC Flashover Voltage by Combustion Flames under Atmospheric Conditions)

  • 김인식
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.1041-1047
    • /
    • 2001
  • In this paper, reduction characteristics of the ac flashover voltage in the horizontal air gap of sphere-sphere/needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrodes. The voltage and current waveforms were measured, when the flashover is occurred, in order to examine the flashover polarity by flame. The reduction characteristics of ac flashover voltage were discussed with the thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that changed by the corona wind and coulomb\`s force. As the results of an experimental investigation, It was found that the reduction of flashover voltages in sphere-sphere system, in comparison with the no-flame case, are 79.9 [%] for k=0, 82.9 [%] for k=0.5, 87.5 [%] for k=1.0, 85.0 [%] for h=0 [cm], 40.8 [%] for h=5 [cm] and 28.2 [%] for h=9 [cm] when ac voltage is applied.

  • PDF

평등/불평등 전계하의 제조공기(I-Air)에 대한 압력별 절연파괴강도 특성 (Dielectric Strength for Imitation Air with Pressure Variation under Uniform and Non-Uniform Fields)

  • 이창욱;이창훈;최은혁;이상호;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.263-266
    • /
    • 2007
  • In this paper approves (AC and DC) high voltage by experimental GIS(Gas Insulated Switchgear) chamber and (AC and DC) power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at (AC and DC) high voltage of Imitation I-Air, $N_2$ : $O_2$ = 79(%) : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's Dielectric Strength using uniform and non-uniform fields(sphere-sphere and Needle-Plane electrode) and studied relations dielectric strength($V_D$) by each P different d.

  • PDF

Potential Profiles and Capacitances of an Ideally Polarizable Electrode/Hard Sphere Electrolyte System

  • Kim, Sang-Youl;Vedam, K.
    • Bulletin of the Korean Chemical Society
    • /
    • 제11권6호
    • /
    • pp.487-493
    • /
    • 1990
  • A complete potential profile of an electrical double layer is calculated from a distribution function of charged particles based upon a model where the effect of a charged electrode and the finite size of ion are explicitly included. Electrons which are distributed on the electrode surface are assumed not to penetrate the electrode/electrolyte boundary. Formation of the constant density regions and their effects on potential and the electrical double layer capacitances are studied in great detail. The distribution of surface electrons as well as the constant density regions are found to be essential in characterizing the electrical double layer. The introduction of the ion size into the prior electrical double layer model of an ideally polarizable electrode/point charged electrolyte system, shows a great improvement in its characteristics mostly at negative potential region.

가열조건이 폴리아미드지의 절연특성에 미치는 영향 (A Study on the heating conditions affect on the insulation characteristics of polyamid papers)

  • 선종호;김우성;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2047-2049
    • /
    • 2000
  • In this study, we describe comparison of insulation characteristics of polyamid papers with heating conditions. The partial discharge behavior until breakdown and breakdown strength for thermal degradation films are observed in $SF_6$ gas chamber. The four layered NOMEX films of thickness of 50${\mu}m$ were used as solid insulation films and the sphere of which diameter is 40mm to sphere electrode system was used and each insulation films were inserted between sphere electrodes. The used gas pressure was 1.0bar and used temperature was each of 250$^{\circ}C$, 270$^{\circ}C$, 300$^{\circ}C$, 320$^{\circ}C$, 350$^{\circ}C$ and the voltage were applied until breakdown films.

  • PDF

수직배치 구대평판 공기 갭에서 연소화염 존재시의 절연파괴 특성 (Breakdown Characteristics of a Vertical Sphere-Plane Air Gap in the Presence of Combustion Flame)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, breakdown characteristics of a vertical sphere-plane air gap in the presence of combustion flame were examined under the application of a.c. and d.c. high-voltages in order to investigate the effect of flame on the dielectric strength of air. Propane gas is used as the fuel of the flame, and the temperature distribution of air around the flame is measured. The polarity effects for the d.c. voltages and breakdown voltages of air when applied both of a.c. and d.c. voltages were examined in the case of the variation of the gap length and the horizontal distance between the flame and the high-voltage sphere electrode. The influence of relative air density, electrification and shape changes of the flame as factors that affect the breakdown voltages were discussed.

화재발생에 따른 연소화염이 공기의 절연내력에 미치는 영항 (Influence of the Combustion Flame on the Dielectric Strength of an Air Gap due to Fire Occurrence)

  • 김인식;하장호
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.30-38
    • /
    • 2002
  • 가공 전력선로 아래에서 화재가 발생되면 전력선은 예기치 않은 섬락사고가 세계 여러나라에서 관측되고 있다. 본 연구에서는 화재의 발생으로 연소화염이 존재할 때, 주변 공기의 절연내력에 미치는 화염의 영향을 알아보기 위해 모의된 조건에서 여러 가지 실험을 행하였다. 침대평판, 구대평판 및 봉대평판 전극을 수직배치한 경우, 교류 및 직류 섬락전압 특성을 조사하였다. 실험결과, 구대평판 갭의 경우, d=1 cm 및 2cm일 때 교류섬락 전압의 상대값은 23.5% 및 30.4%이며, d=4cm인 경우는 37.8%인 것으로 나타났으며, 화염이 없는 경우에 비해 평균 33.0%인 것으로 나타났다. 직류전압 인가시는 화염이 없는 경우, 부극성의 섬락전압이 정극성보다 높았으나, 화염이 존재할 경우는 반대로 정극성이 부극성 전압보다 높은 것으로 나타났다.